Early Functional Treatment of Intra-articular Fractures of the Proximal Interphalangeal Joint of the Finger Using a Modified Traction Device

被引:2
|
作者
Mattiassich, G. [1 ]
Mayrhofer-Stelzhammer, M. [1 ]
Huber, W. [1 ]
Dorninger, L. [1 ]
Kroepfl, A. [1 ]
机构
[1] Unfallkrankenhaus AUVA Linz, A-4020 Linz, Austria
关键词
fractures of the base of the middle phalanx; distraction treatment; DISLOCATIONS; FIXATION; SYSTEM;
D O I
10.1055/s-0033-1349073
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Treatment of intra-articular fractures of the middle phalanx is both difficult and controversial. We report our experience of using a modified dynamic traction device (mTD) utilizing only one pin in the head of the middle phalanx and thus facilitating further open reconstructive surgery at the proximal interphalangeal joint (PIP). The pin does not necessarily have to be inserted in the movement axis of the joint. Aim of the Study: The aim of the study was to a) determine the effectiveness of the mTD, particularly in comparison with other distraction systems used in the treatment of middle phalanx fractures as described in the literature, and b) compare the results of patients treated using an mTD only with the results of those treated with an mTD in combination with additional open reconstructive surgery. Patients and Methods: 26 patients with a mean age of 37 years were treated for intra-articular fractures of the base of the middle phalanx using an mTD in the period between 2007 and 2011. 13 of these patients also underwent additional open reconstructive surgery. 18 of the 26 patients (69%) were reevaluated after 33 months (range 9-44 months); 10 of these had undergone additional open reconstructive surgery. Followup of 14 of the patients included their completion of a structured questionnaire and calculation of their DASH scores as well as radiological and clinical examinations. 4 patients completed the questionnaire and had their DASH score calculated. Measurement of range of motion was performed by the treating general practitioner. Patient records were analysed with a particular focus on complications and duration of therapy. Results: The mTD was used for an average of 34 days (range 8-53 days) and overall treatment took an average of 74 days (range 66-154 days). 4 pin tract infections were reported. The mean DASH score was 6.4. The mean range of motion in the PIP joint was 70 degrees (range 30-110 degrees). The range of motion of the PIP and DIP joints (61 degrees) was significantly poorer in patients with additional surgery than that (82 degrees) in patients with sole mTD treatment. Treatment with the mTD gave results similar to those obtained with other distraction devices with good subjective evaluation by the patients. Conclusion: Dynamic traction with the help of the modified traction devices is suitable for treating intra-articular fractures of the proximal interphalangeal joint, as demonstrated by a comparison with the literature. Patients who underwent additional open surgery showed less favorable results. The present method has the advantage that only one wire needs to be inserted subcapitaly at a distance from the fracture in the middle finger and this facilitates further surgical interventions.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [1] PINS AND RUBBER TRACTION SYSTEM FOR INTRA-ARTICULAR PROXIMAL INTERPHALANGEAL JOINT FRACTURES REVISITED
    Debus, G.
    Courvoisier, A.
    Wimsey, S.
    Pradel, P.
    Moutet, F.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2010, 35E (05) : 396 - 401
  • [2] Hand-based swing traction splinting for intra-articular proximal interphalangeal joint fractures
    Hirth, Melissa J.
    Jacobs, David J.
    Sleep, Kate
    HAND THERAPY, 2013, 18 (02) : 42 - 56
  • [3] Osteosynthesis of intra-articular fractures in the proximal interphalangeal joint with Kirschner wires
    Larsen, MS
    Leicht, P
    Lassen, E
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2000, 34 (02): : 149 - 153
  • [4] Intra-articular nodular fasciitis of the proximal interphalangeal joint of a finger: A case report
    Choughri, H.
    Coindre, J. -M.
    Leclere, F. M.
    HAND SURGERY & REHABILITATION, 2019, 38 (01): : 74 - 78
  • [5] The Suzuki frame for complex intra-articular fractures of the proximal interphalangeal joint of the fingers
    Keramidas, Evangelos
    Solomos, Markos
    Page, Robert E.
    Miller, Gavin
    ANNALS OF PLASTIC SURGERY, 2007, 58 (05) : 484 - 488
  • [6] Management of difficult intra-articular fractures or fracture dislocations of the proximal interphalangeal joint
    Liodaki, E.
    Xing, S. G.
    Mailaender, P.
    Stang, F.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2015, 40 (01) : 16 - 23
  • [8] Management of intra-articular fractures of the proximal interphalangeal joint by internal fixation and bone grafting
    W. Khan
    M. Agarwal
    L. Muir
    Archives of Orthopaedic and Trauma Surgery, 2004, 124 : 688 - 691
  • [9] Management of intra-articular fractures of the proximal interphalangeal joint by internal fixation and bone grafting
    Khan, W
    Agarwal, M
    Muir, L
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (10) : 688 - 691
  • [10] Intra-articular Osteotomy for Malunited Proximal Interphalangeal Joint Fracture
    Yang, Chaoqun
    Wei, Jingchao
    Xu, Jianguang
    Xu, Lei
    Lu, Jiuzhou
    ANNALS OF PLASTIC SURGERY, 2019, 83 (01) : 34 - 39