Implant Stability Measurements of Two Immediate Loading Protocols for the Edentulous Mandible: Rigid and Semi-rigid Splinting of the Implants

被引:17
|
作者
Lee, Hyung Joo
de Mattias Sartori, Ivete Aparecida [1 ]
Alcantara, Paola Rebelatto
Vieira, Rogeria Acedo [2 ]
Suzuki, Dalton
Kiatake Fontao, Flavia Gasparini [3 ]
Tiossi, Rodrigo [1 ,4 ]
机构
[1] ILAPEO, Latin Amer Inst Dent Res & Educ, Dept Prosthodont, BR-80710150 Curitiba, Parana, Brazil
[2] ILAPEO, Latin Amer Inst Dent Res & Educ, Dept Implantol, BR-80710150 Curitiba, Parana, Brazil
[3] ILAPEO, Latin Amer Inst Dent Res & Educ, Dept Radiol, BR-80710150 Curitiba, Parana, Brazil
[4] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
关键词
edentulous jaw; implant-supported fixed prosthesis; immediate dental implant loading; FINITE-ELEMENT-ANALYSIS; RESONANCE FREQUENCY-ANALYSIS; BONE-DENSITY; INSERTION TORQUE; FIXED PROSTHESIS; DENTAL IMPLANTS; FOLLOW-UP; OVERDENTURES; CANTILEVER; SUCCESS;
D O I
10.1097/ID.0b013e31826b1c68
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)
引用
收藏
页码:486 / 490
页数:5
相关论文
共 5 条
  • [1] Finite Element Analysis of 2 Immediate Loading Systems in Edentulous Mandible: Rigid and Semirigid Splinting of Implants
    Teixeira, Marcelo Fontes
    Ramalho, Saturnino Aparecido
    de Mattias Sartori, Ivete Aparecida
    Lehmann, Roberto Brunow
    IMPLANT DENTISTRY, 2010, 19 (01) : 39 - 49
  • [2] A TECHNIQUE FOR AN ACCELERATED RIGID SPLINTING OF MULTIPLE IMPLANTS FOR IMMEDIATE LOADING
    Scarano, A.
    Sinjari, B.
    Murmura, G.
    Assenza, B.
    Carinci, F.
    Brunelli, G.
    EUROPEAN JOURNAL OF INFLAMMATION, 2012, 10 (01): : 95 - 99
  • [3] Two-piece inflatable and semi-rigid penile implants: an effective alternative?
    Paolo Verze
    Marco Capece
    Gianluigi Califano
    Roberto La Rocca
    International Journal of Impotence Research, 2020, 32 : 24 - 29
  • [4] Two-piece inflatable and semi-rigid penile implants: an effective alternative?
    Verze, Paolo
    Capece, Marco
    Califano, Gianluigi
    La Rocca, Roberto
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2020, 32 (01) : 24 - 29
  • [5] Clinical Effectiveness of 6.5-mm-Long Implants to Support Two-Implant Fixed Prostheses in Premolar-Molar Region: The Influence of Immediate Loading and the Length of Splinting Implant
    Anitua, Eduardo
    Flores, Carlos
    Flores, Javier
    Alkhraisat, Mohammad Hamdan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E688 - E693