Seismic behavior of novel GFRP bar reinforced concrete beam-column joints internally reinforced with an FRP tube

被引:16
|
作者
Lin, Guan [1 ]
Zeng, Jun-Jie [2 ]
Liang, Sheng-Da [2 ]
Liao, JinJing [2 ]
Zhuge, Yan [3 ]
机构
[1] Southern Univ Sci & Technol, Dept Ocean Sci & Engn, Shenzhen 518055, Guangdong, Peoples R China
[2] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Peoples R China
[3] Univ South Australia, UniSA STEM, Adelaide, SA 5095, Australia
关键词
Fiber-reinforced polymer (FRP) reinforcement; Beam-column joints; FRP tube; Confinement; Seismic performance; Energy dissipation;
D O I
10.1016/j.engstruct.2022.115100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to many advantages, fiber-reinforced polymer (FRP) bars have been considered as a promising alternative to steel bars in reinforced concrete (RC) structures. The use of FRP bars in beam-column joints has been reported in the literature. However, it has been found that the energy dissipation capacity of an FRP-RC beam-column joint is dramatically lower than that of the corresponding steel-RC joint. The present study attempts to develop a novel form of FRP-RC beam-column joints with superior energy dissipation capacity. The proposed joints incorporate an internal FRP tube in the joint zone, which provides confinement to the inner concrete and shear resistance of the joint. Compared with existing reinforcement techniques using stiffeners or internal diaphragms, the proposed use of an internal FRP tube is much easier to be implemented. To demonstrate the advantages of the proposed FRP-RC beam-column joints, an experimental program consisting of 6 FRP-RC beam-column joint specimens was carried out. The effects of fiber type, thickness, and fiber orientation of the FRP tube in the joint zone were investigated. The test results in terms of failure modes, hysteretic behaviors, and energy dissipation capacities of the test specimens were discussed in detail. The test results demonstrated the efficiency of the FRP tube, espe-cially the one with a fiber angle of +/- 45 degrees, in enhancing the energy dissipation capacity of FRP-RC beam-column joints.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Research on seismic behavior of GFRP-reinforced concrete beam-column joints
    Yang D.
    Jia B.
    Guo R.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (10): : 225 - 236
  • [2] Seismic Behavior of Beam-Column Joints Reinforced with GFRP Bars and Stirrups
    Mady, Mohamed
    El-Ragaby, Amr
    El-Salakawy, Ehab
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (06) : 875 - 886
  • [3] Seismic behavior of reinforced concrete beam-column joint strengthened with GFRP
    Ouyang, Y
    Gu, XL
    Huang, YH
    Qian, ZZ
    FIBRE-REINFORCEMENT POLYMER: REINFORCEMENT FOR CONCRETE STRUCTURES, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1107 - 1116
  • [4] Experimental study on seismic performance of concrete beam-column joints reinforced with FRP
    Peng, Ya-Ping
    Wang, Tie-Cheng
    Zhang, Yu-Min
    Xu, Yao
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2007, 39 (12): : 1969 - 1973
  • [5] Seismic Behavior of Reinforced Concrete Exterior Wide Beam-Column Joints
    Li, Bing
    Kulkarni, Sudhakar A.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (01): : 26 - 36
  • [6] Behavior of heated damaged reinforced concrete beam-column joints strengthened with FRP
    Al-Rousan, Rajai Z.
    Alkhawaldeh, Ayah
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2021, 15
  • [7] Seismic rehabilitation of reinforced concrete frame interior beam-column joints with FRP composites
    Pantelides, Chris P.
    Okahashi, Yasuteru
    Reaveley, L. D.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (04) : 435 - 445
  • [8] Seismic Performance of Strengthened Reinforced Concrete Beam-Column Joints Using FRP Composites
    Li, Bing
    Chua, H. Y. Grace
    JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (10) : 1177 - 1190
  • [9] Seismic Behavior of Reinforced Concrete Beam-Column Joints with Vertically Distributed Reinforcement
    Li, Bing
    Tran, Cao Thanh Ngoc
    ACI STRUCTURAL JOURNAL, 2009, 106 (06) : 790 - 799
  • [10] REINFORCED CONCRETE BEAM-COLUMN JOINTS FOR SEISMIC LOADING.
    Fenwick, R.C.
    Irvine, H.M.
    Bulletin of the New Zealand Society for Earthquake Engineering, 1977, 10 (04): : 174 - 185