Analysis of "Accuracy of a 14-Day Factory Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes"

被引:2
|
作者
Kompala, Tejaswi [1 ]
Neinstein, Aaron B. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Ctr Digital Hlth Innovat, San Francisco, CA 94143 USA
来源
关键词
continuous glucose monitoring; diabetes mellitus; telehealth; digital health; ACCEPTABILITY; CARE;
D O I
10.1177/1932296820967004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study by Alva et al, accuracy of a second-generation factory calibrated continuous glucose monitoring system is evaluated. Compared to the first-generation FreeStyle Libre 14-day system (FSL), accuracy was improved throughout the 14-day wear period, including improved accuracy in hypoglycemia for adults and youth. The addition of optional real-time alerts for hypoglycemia and hyperglycemia as well as an integrated continuous glucose monitor (iCGM) designation by the FDA may further enable users to benefit from using CGM in real time, including in future automated insulin delivery systems. As CGM accuracy, affordability, and accessibility improve, we anticipate increased uptake of CGM by people on intensive insulin therapy, and also potential benefits and expansion into a broader patient population. There are growing opportunities to leverage cloud-connected CGM devices in the increasingly virtual, continuous telehealth-driven diabetes care model, which will require more focus on development and use of data interoperability standards.
引用
收藏
页码:78 / 80
页数:3
相关论文
共 50 条
  • [1] Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes
    Alva, Shridhara
    Bailey, Timothy
    Brazg, Ronald
    Budiman, Erwin S.
    Castorino, Kristin
    Christiansen, Mark P.
    Forlenza, Gregory
    Kipnes, Mark
    Liljenquist, David R.
    Liu, Hanqing
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (01): : 70 - 77
  • [2] Improved Accuracy of 14-Day Factory-Calibrated FreeStyle Libre System with New Glucose Algorithm
    Karinka, Shridhara Alva
    Bailey, Timothy S.
    Brazg, Ronald L.
    Budiman, Erwin S.
    Castorino, Kristin
    Christiansen, Mark P.
    Liljenquist, David R.
    Liu, Hanqing
    DIABETES, 2019, 68
  • [3] Accuracy of the Third Generation of a 14-Day Continuous Glucose Monitoring System
    Alva, Shridhara
    Brazg, Ronald
    Castorino, Kristin
    Kipnes, Mark
    Liljenquist, David R.
    Liu, Hanqing
    DIABETES THERAPY, 2023, 14 (04) : 767 - 776
  • [4] Accuracy of the Third Generation of a 14-Day Continuous Glucose Monitoring System
    Shridhara Alva
    Ronald Brazg
    Kristin Castorino
    Mark Kipnes
    David R. Liljenquist
    Hanqing Liu
    Diabetes Therapy, 2023, 14 : 767 - 776
  • [5] Factory Calibrated Continuous Glucose Monitoring System Accuracy During Exercise In Adolescents With Type 1 Diabetes Mellitus
    Dyess, Ryan
    Thrasher, Bradly
    Wintergerst, Kupper
    Feygin, Yana
    McKay, Tim
    HORMONE RESEARCH IN PAEDIATRICS, 2022, 95 (SUPPL 1): : 45 - 46
  • [6] Factory-Calibrated Continuous Glucose Monitoring System Accuracy During Exercise in Adolescents With Type 1 Diabetes Mellitus
    Dyess, Ryan J.
    McKay, Timothy
    Feygin, Yana
    Wintergerst, Kupper
    Thrasher, Bradly J.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (03): : 584 - 591
  • [7] Flash Continuous Glucose Monitoring (FreeStyle Libre 14-Day System) for Self-Management of Diabetes Mellitus
    Choi, Hiu Ying Joanna
    AMERICAN FAMILY PHYSICIAN, 2021, 103 (11) : 688 - 690
  • [8] Accuracy of a Factory-Calibrated Continuous Glucose Monitor in Individuals With Diabetes on Hemodialysis
    Villard, Orianne
    Breton, Marc D.
    Rao, Swati
    Voelmle, Mary K.
    Fuller, Morgan R.
    Myers, Helen E.
    McFadden, Ryan K.
    Luke, Zander S.
    Wakeman, Christian A.
    Clancy-Oliveri, Mary
    Basu, Ananda
    Stumpf, Meaghan M.
    DIABETES CARE, 2022, 45 (07) : 1666 - 1669
  • [9] Feasibility of Using a Factory-Calibrated Continuous Glucose Monitoring System to Diagnose Type 2 Diabetes
    Frank, Spencer
    Hames, Kazanna C.
    Jbaily, Abdulrahman
    Park, Jee Hye
    Stroyeck, Chuck
    Price, David
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (12) : 907 - 914
  • [10] Safety and Accuracy of Factory-Calibrated Continuous Glucose Monitoring in Pediatric Patients Undergoing Hematopoietic Stem Cell Transplantation
    Sopfe, Jenna
    Vigers, Tim
    Pyle, Laura
    Giller, Roger H.
    Forlenza, Gregory P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (10) : 727 - 733