Hybrid image visualization tool for 3D integration of CT coronary anatomy and quantitative myocardial perfusion PET

被引:3
|
作者
Marinelli, Martina [1 ]
Positano, Vincenzo [2 ]
Nekolla, Stephan G. [3 ]
Marcheschi, Paolo [2 ]
Todiere, Giancarlo [2 ]
Esposito, Natalia [1 ]
Puzzuoli, Stefano [1 ]
L'Abbate, Giuseppe A. [2 ]
Marraccini, Paolo [1 ]
Neglia, Danilo [1 ,2 ]
机构
[1] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[2] CNR Reg Toscana, Fdn Gabriele Monasterio, I-56124 Pisa, Italy
[3] Tech Univ Munich, Nukl Med Klin, D-81675 Munich, Germany
关键词
CAD; Hybrid imaging; Myocardial flow reserve; XML; 3D visualization; MAGNETIC-RESONANCE; DIAGNOSTIC PERFORMANCE; REGISTRATION; ANGIOGRAPHY; VIABILITY; HEART; SUM;
D O I
10.1007/s11548-012-0777-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multimodal cardiac imaging by CTA and quantitative PET enables acquisition of patient-specific coronary anatomy and absolute myocardial perfusion at rest and during stress. In the clinical setting, integration of this information is performed visually or using coronary arteries distribution models. We developed a new tool for CTA and quantitative PET integrated 3D visualization, exploiting XML and DICOM clinical standards. The hybrid image tool (HIT) developed in the present study included four main modules: (1) volumetric registration for spatial matching of CTA and PET data sets, (2) an interface to PET quantitative analysis software, (3) a derived DICOM generator able to build DICOM data set from quantitative polar maps, and (4) a 3D visualization tool of integrated anatomical and quantitative flow information. The four modules incorporated in the HIT tool communicate by defined standard XML files: XML-transformation and XML MIST standards. The HIT tool implements a 3D representation of CTA showing real coronary anatomy fused to PET-derived quantitative myocardial blood flow distribution. The technique was validated on 16 data sets from EVINCI study population. The validation of the method confirmed the high matching between "original" and derived data sets as well as the accuracy of the registration procedure. Three-dimensional integration of patient- specific coronary artery anatomy provided by CTA and quantitative myocardial blood flow obtained from PET imaging can improve cardiac disease assessment. The HIT tool introduced in this paper may represent a significant advancement in the clinical use of this multimodal approach.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 50 条
  • [1] Hybrid image visualization tool for 3D integration of CT coronary anatomy and quantitative myocardial perfusion PET
    Martina Marinelli
    Vincenzo Positano
    Stephan G. Nekolla
    Paolo Marcheschi
    Giancarlo Todiere
    Natalia Esposito
    Stefano Puzzuoli
    Giuseppe A. L’Abbate
    Paolo Marraccini
    Danilo Neglia
    International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 221 - 232
  • [2] Definition of Vascular Territories on Myocardial Perfusion Images by Integration with True Coronary Anatomy: A Hybrid PET/CT Analysis
    Javadi, Mehrbod S.
    Lautamaeki, Riikka
    Merrill, Jennifer
    Voicu, Corina
    Epley, William
    McBride, Gerald
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) : 198 - 203
  • [3] A new method for 3D integration of coronary anatomy and quantitative cardiac PET imaging
    Marinelli, M.
    Positano, V.
    Marcheschi, P.
    Todiere, G.
    Esposito, N.
    L'Abbate, G. A.
    Marraccini, P.
    Nekolla, S. G.
    Neglia, D.
    EUROPEAN HEART JOURNAL, 2012, 33 : 191 - 191
  • [4] Relationship Between Descriptors of Coronary Atherosclerosis by Coronary Ct Angiography and Quantitative Myocardial Perfusion as Assessed by Hybrid PET/CT Imaging
    Naya, Masanao
    Blankstein, Ron
    Sitek, Arkadiusz
    Williams, Julie
    Fantony, Jolene
    Dorbala, Sharmila
    Di Carli, Marcelo
    CIRCULATION, 2010, 122 (21)
  • [5] MR Perfusion Visualization in 3D Image
    Cap, M.
    Gescheidtova, E.
    Marcon, P.
    Bartusek, K.
    Kroutilova, E.
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 380 - 384
  • [6] Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography
    Ryo Nakazato
    Daniel S. Berman
    Damini Dey
    Ludovic Le Meunier
    Sean W. Hayes
    Jimmy S. Fermin
    Victor Y. Cheng
    Louise E. J. Thomson
    John D. Friedman
    Guido Germano
    Piotr J. Slomka
    Journal of Nuclear Cardiology, 2012, 19 : 265 - 276
  • [7] Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography
    Nakazato, Ryo
    Berman, Daniel S.
    Dey, Damini
    Le Meunier, Ludovic
    Hayes, Sean W.
    Fermin, Jimmy S.
    Cheng, Victor Y.
    Thomson, Louise E. J.
    Friedman, John D.
    Germano, Guido
    Slomka, Piotr J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (02) : 265 - 276
  • [8] Quantitative myocardial perfusion 82Rb-PET assessed by hybrid PET/coronary CT: normal values and diagnostic performance
    Freitag, Martin
    Bremerich, Jens
    Wild, Damian
    Haaf, Philip
    Zellweger, Michael
    Caobelli, Federico
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [9] Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT
    Ryo Nakazato
    Damini Dey
    Erick Alexánderson
    Aloha Meave
    Moisés Jiménez
    Edgar Romero
    Rodrigo Jácome
    Marco Peña
    Daniel S. Berman
    Piotr J. Slomka
    Journal of Nuclear Cardiology, 2012, 19 : 482 - 491
  • [10] Automatic alignment of myocardial perfusion PET with 64-slice coronary CT angiography on hybrid PET/CT
    Nakazato, Ryo
    Slomka, Piotr
    Alexanderson, Erick
    Meave, Aloha
    Jimenez-Santos, Moises
    Romero, Edgar
    Jacome, Rodrigo
    Pena, Marco
    Dey, Damini
    Berman, Daniel
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52