Total Ionizing Dose Radiation Test on the Temperature Sensor TMP36 from Analog Devices

被引:0
|
作者
Alvarez, Maite [1 ]
Jimenez, Juan J. [1 ]
Gonzalez-Guerrero, Miguel [1 ]
Hernando, Carlos [1 ]
Guerrero, Hector [1 ]
机构
[1] INTA, Madrid 28850, Spain
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
TMP36 temperature sensors were irradiated with Co-60 gamma rays up to 35 krad(Si). This temperature sensor will be used as a total ionizing dose sensor in a radiation monitor that will be on board the Spanish Earth observation satellite SEOSAT/INGENIO. Several samples were irradiated at different dose rates while their response was continuously measured. The sensitivity of the TMP36 to the total ionizing dose has been assessed by studying the evolution of the next three metrics: the output voltage, its temperature dependence and the power consumption. It has been observed that the degradation of these parameters increase significantly at doses higher than about 7 krad(Si), independently of the dose rate.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The Application of Temperature Sensor TMP36 and the Assembly Algorithm of Multidigit Decimal Resolving
    Ren, Yongjie
    Ding, Xiaohua
    Yang, Xueyou
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 4210 - +
  • [2] Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor
    Gonzalez-Guerrero, Miguel
    Jimenez, Juan J.
    Hernando, Carlos
    Alvarez, Maite
    Guerrero, Hector
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 2461 - 2468
  • [3] Total-Ionizing Dose and Single-Event Effect Test Results of Analog and Mixed Signal Devices from Analog Devices
    Chen, Dakai
    Decker, Tom
    Mo, Andy
    Harris, Jonathan
    Wendel, Nathan
    Xiao, Charlie
    Rezgui, Sana
    Hart, Shirley
    Horton, Bryan
    Musil, Paul
    2018 IEEE RADIATION EFFECTS DATA WORKSHOP (REDW), 2018, : 252 - 259
  • [4] Total ionizing dose effects in MOS devices for different radiation sources
    Kim, HS
    Kim, Y
    Noh, SJ
    Kim, MH
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 45 : S820 - S823
  • [5] Neutron and gamma radiation tests of the analog devices TMP37 temperature sensors
    Mockett, PM
    Smith, RM
    Twomey, MS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2293 - 2297
  • [6] Neutron and gamma radiation tests of the Analog Devices TMP37 temperature sensors
    Mockett, PM
    Smith, RM
    Twomey, MS
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 866 - 869
  • [7] Application of Total Ionizing Dose Radiation Test Standards to SiC MOSFETs
    Yu, Qingkui
    Ali, Waqas
    Cao, Shuang
    Wang, He
    Lv, He
    Sun, Yi
    Mo, Rigen
    Wang, Qianyuan
    Mei, Bo
    Sun, Jiajia
    Zhang, Hongwei
    Tang, Min
    Bai, Song
    Zhang, Teng
    Bai, Yun
    Zhang, Chenrui
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (05) : 1127 - 1133
  • [8] Dosimetry Techniques and Radiation Test Facilities for Total Ionizing Dose Testing
    Ravotti, Federico
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (08) : 1440 - 1464
  • [9] TOTAL IONIZING DOSE EFFECTS AND RADIATION TESTING OF COMPLEX MULTIFUNCTIONAL VLSI DEVICES
    Boychenko, Dmitry
    Kalashnikov, Oleg
    Nikiforov, Alexander
    Ulanova, Anastasija
    Bobrovsky, Dmitry
    Nekrasov, Pavel
    FACTA UNIVERSITATIS-SERIES ELECTRONICS AND ENERGETICS, 2015, 28 (01) : 153 - 164
  • [10] Multifunctional Equipment and Test Results for Total Ionizing Dose Testing of Analog Integrated Circuits
    Bakerenkov, Alexander S.
    Chubunov, Pavel A.
    Anashin, Vasily S.
    Rodin, Alexander S.
    Felitsyn, Vladislav A.
    2016 IEEE RADIATION EFFECTS DATA WORKSHOP (REDW), 2016, : 88 - 91