Magnet Design and Measurement Results of the Solenoids and Bunch Compressor Bending Magnets of the SwissFEL Test Facility

被引:2
|
作者
Negrazus, M. [1 ]
Gabard, A. [1 ]
Sanfilippo, S. [1 ]
Sidorov, S. [1 ]
Vrankovic, V. [1 ]
Kim, Y. J. [2 ]
Ganter, R. [1 ]
Pedrozzi, M. [1 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Idaho State Univ, Dept Phys, Idaho Accelerator Ctr, Pocatello, ID 83209 USA
关键词
Accelerator magnets; magnetic fields; solenoids;
D O I
10.1109/TASC.2011.2177794
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The SwissFEL Injector Test Facility at the Paul Scherrer Institute (PAI/Switzerland) started its operation in August 2010. This Facility represents the first stage of the 6 GeV acceleration complex foreseen for the SwissFEL X-Ray coherent light source planned at the PSI. The 250 MeV Injector consists of an S-Band RF photo injector followed by four S-Band acceleration structures of 4 m length each. For fine focusing corrections each accelerating structure is surrounded by four solenoids (WFS) of 0.8 m length and a maximum field of 0.1 T. Each solenoid consists of two coils in one yoke tube. To decrease the bunch length of the electron beam a magnetic bunch compressor chicane with four dipoles (AFBC2) providing a maximum magnetic field of 0.4 T for a length of 0.25 m was build. The central dipoles of the compressor chicane are sited on a movable girder to allow extensive compression studies with dipole angles between 0 degrees and 5 degrees. The preservation of a high brightness and a low emittance for the femto-second electron pulse impose severe tolerances in the field quality and in the magnet positioning. In this paper we review the design of two magnet types and discuss the results of field quality and magnetic axis measurements in terms of the specifications.
引用
下载
收藏
页数:4
相关论文
共 50 条
  • [1] A relational database for magnets and measurement systems at the Fermilab Magnet Test Facility
    Sim, JW
    Brown, BC
    Glass, HD
    Harding, DJ
    Mishra, CS
    Russell, AD
    TromblyFreytag, K
    Walbridge, DGC
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 2282 - 2284
  • [2] Layout of bunch compressor for Beijing XFEL test facility
    Zhu, Xiongwei
    Du, Yingchao
    He, Xiaozhong
    Yang, Yufeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02): : 250 - 255
  • [3] Microbunch instability in the Beijing XFEL test facility bunch compressor
    Yang Yu-Feng
    Zhu Xiong-Wei
    Li Ming
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 (02): : 194 - 198
  • [4] Measurement of the bunch length at the TESLA Test Facility linac
    Hanke, K
    MICRO BUNCHES WORKSHOP, 1996, (367): : 406 - 410
  • [5] Emittance dilution and magnet design for the TTF FEL second bunch compressor
    Ivanov, I.N.
    Kukarnikov, S.I.
    Molodozhentsev, A.Yu.
    Petrov, V.A.
    Shevtsov, V.Ph.
    Limberg, T.
    Marx, M.
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 1 : 491 - 493
  • [6] Emittance dilution and magnet design for the TTF FEL second bunch compressor
    Ivanov, IN
    Kukarnikov, SI
    Molodozhentsev, AY
    Petrov, VA
    Shevtsov, VP
    Limberg, T
    Marx, M
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 491 - 493
  • [7] Design, fabrication, and test,of a superconducting dipole magnet based on tilted solenoids
    Caspi, S.
    Dietderich, D. R.
    Ferracin, P.
    Finney, N. R.
    Fuery, M. J.
    Gourlay, S. A.
    Hafalia, A. R.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 2266 - 2269
  • [8] Design and test on moving-magnet linear compressor
    Institute of Chemical Machinery Engineering, Zhejiang University, Hangzhou 310027, China
    不详
    Zhejiang Daxue Xuebao (Gongxue Ban), 2008, 2 (229-233):
  • [9] A multistage compressor test facility: Uncertainty analysis and preliminary test results
    Bettocchi, R
    Pinelli, M
    Spina, PR
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 170 - 177
  • [10] Results of magnet tests as a basis for the design of ITER magnets
    Komarek, P