A closed-form solution for the wind-induced responses of transmission lines considering the failure of adjacent towers

被引:7
|
作者
Fu, Xing [1 ]
Du, Wen-Long [1 ]
Li, Hong -Nan [1 ,2 ]
Li, Gang [1 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116023, Peoples R China
[2] Shenyang Jianzhu Univ, Sch Civil Engn, Shenyang 110168, Peoples R China
基金
中国国家自然科学基金;
关键词
Transmission line; Large deformation; Quasi -static response; Cascading failure; Equivalent wind load; BUFFETING RESPONSE; CONDUCTORS;
D O I
10.1016/j.jweia.2022.105110
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Some towers in transmission lines may collapse first under the gust wind and have pulling effects on conductors, which may trigger the cascade failure when the unbalanced force on the adjacent tower is large. Thus, a closedform solution is proposed to predict conductor responses induced by both the failed tower and wind loads. The total wind-induced response is divided into the mean component affected by support displacement and fluctuating component around the static equilibrium, which can be determined by nonlinear static analysis and influence line, respectively. The equilibrium iteration method and trapezoidal equivalent wind pressure are proposed to correct the response distortion caused by the large deformation and non-uniform wind pressure. Then, the power spectral density and root mean square of responses considering three-dimensional correlation are provided. Finally, parameter analysis investigates the influence of support displacement, initial horizontal tension, and horizontal span on reaction force and gust response factor (GRF). The results show that the proposed closed-form solution has high accuracy and efficiency, and the influence of large deformation and wind pressure forms on the wind-induced responses cannot be ignored. Moreover, both the lateral reaction force and GRF are significantly sensitive to the lateral support displacement.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Wind Field Characteristics of Butte and the Influence on the Wind-Induced Responses of Transmission Towers
    Zhang, Yan
    Huang, Wenfeng
    Wang, Lisha
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [2] Time-Frequency Buffeting Responses of Transmission Lines Excited by Two-Dimensional Turbulent Wind: Closed-Form Solution
    Du, Wen-Long
    Fu, Xing
    Li, Hong-Nan
    Li, Gang
    Liu, Chun-Guang
    JOURNAL OF ENGINEERING MECHANICS, 2023, 149 (12)
  • [3] A Closed-Form Sensitivity Analysis of Transmission Lines
    Antonini, G.
    De Camillis, L.
    Ruscitti, E.
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2009, 24 (04): : 352 - 360
  • [4] Wind-induced interference effects on two adjacent cooling towers
    Orlando, M
    ENGINEERING STRUCTURES, 2001, 23 (08) : 979 - 992
  • [5] Wind-induced failure process of RC hyperbolic cooling towers considering the material nonlinearity
    Zhang J.-F.
    Pei H.
    Zhu B.
    Liu Q.-S.
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 (03): : 228 - 238
  • [6] A Closed-Form Transient Response of Coupled Transmission Lines
    Zahedi, Fatemeh
    Mehrshahi, Esfandiar
    Jahanian, Ali
    IEEE SYSTEMS JOURNAL, 2022, 16 (01): : 801 - 809
  • [7] Passive closed-form expression of RLCG transmission lines
    Tanji, Y
    Ushida, A
    Nakhla, MS
    2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL III, PROCEEDINGS, 2002, : 795 - 798
  • [8] A Closed-Form Solution for Untransposed Transmission-Lines Fault Location With Nonsynchronized Terminals
    Vieira, Douglas A. G.
    Oliveira, Diogo B.
    Lisboa, Adriano C.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) : 524 - 525
  • [9] Analytical study on wind-induced vibration of power transmission towers
    Yasui, H
    Marukawa, H
    Momomura, Y
    Ohkuma, T
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 83 : 431 - 441