The use of immunomagnetic separation of erythrocytes in the in vivo flow cytometer-based micronucleus assay

被引:6
|
作者
Abramsson-Zetterberg, Lilianne [1 ]
Carlsson, Rickard [1 ]
Sand, Salomon [1 ]
机构
[1] Swedish Natl Food Agcy, Risk Benefit Dept, S-75126 Uppsala, Sweden
关键词
Micronucleus; Flow cytometry; Immunomagnetic separation; Benzo(a)pyrene; MOUSE BONE-MARROW; DOSE-RESPONSE; TIME-COURSE; POLYCHROMATIC ERYTHROCYTES; INDUCTION; RETICULOCYTES; ENUMERATION; THRESHOLD; ADDUCTS; BLOOD;
D O I
10.1016/j.mrgentox.2012.12.010
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The use of sensitive test systems makes it possible to detect weakly genotoxic chemicals and to better define the shape of dose response relationships, which make it easier to interpret the mechanism behind possible effects. In this study we have refined the flow cytometer-based micronucleus assay by use of a cytometer equipped with two lasers. Since micronucleated young polychromatic erythrocytes, MNPCE, are very few in number among the cells in peripheral blood, about one or two out of 100,000 erythrocytes, there is always a risk that other cells, doublets or crystals, by mistake will be classified as a MNPCE. With immunomagnetic separation of the very youngest erythrocytes which are transferrin-positive (Trf + Ret) prior to analysis, we have obtained an almost pure (>98%) Trf + Ret-population. To clarify whether this separation of cells prior to analysis increases the sensitivity of the already sensitive and further refined flow cytometer-based micronucleus assay, we studied the dose response towards benzo(a)pyrene, B[a]P in the low-dose region, 0-30 mg/kg bw. Thirty FVB mice were intraperitoneally injected with B[a]P. From the same blood samples collected from these mice, cells were prepared in the two different ways and analyzed in the flow-cytometer equipped with two lasers. The lowest dose of B[a]P that can be reliably determined without being overwhelmed by the estimated error was about the same for the two methods, about 7 mg/kg bw, i.e. the immunomagnetic separation did not increase the sensitivity. A second study with BalbC mice strengthens the result obtained with the FVB mice. Prior to the low-dose study the optimal sampling time for the two methods was determined. In this case, the water-solouble chemical acrylamide was used. The time courses obtained show almost the same shape of the curves, with a maximum of fMNPCE and fMNTrf + Ret at about 40-50 h after exposure. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [1] The dose-response relationship at very low doses of acrylamide is linear in the flow cytometer-based mouse micronucleus assay
    Abramsson-Zetterberg, L
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2003, 535 (02) : 215 - 222
  • [2] Fluorescent dye-based simple staining for in vivo micronucleus test with flow cytometer
    Harada, Asako
    Matsuzaki, Kaori
    Takeiri, Akira
    Tanaka, Kenji
    Mishima, Masayuki
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2013, 751 (02) : 85 - 90
  • [3] Automation of the in vitro micronucleus assay using the Imagestream® imaging flow cytometer
    Rodrigues, Matthew A.
    CYTOMETRY PART A, 2018, 93A (07) : 706 - 726
  • [4] Evaluation of a flow cytometer-based functional assay using platelet-rich plasma in the diagnosis of heparin-induced thrombocytopenia
    Althaus, Karina
    Pelzl, Lisann
    Hidiatov, Oleg
    Amiral, Jean
    Marini, Irene
    Bakchoul, Tamam
    THROMBOSIS RESEARCH, 2019, 180 : 55 - 61
  • [5] Semicarbazide is not genotoxic in the flow cytometry-based micronucleus assay in vivo
    Abramsson-Zetterberg, L
    Svensson, K
    TOXICOLOGY LETTERS, 2005, 155 (02) : 211 - 217
  • [6] DETERMINATION OF ANTI-IGA ANTIBODIES WITH A FLOW CYTOMETER-BASED MICROBEAD IMMUNOASSAY (MIA)
    SYRJALA, MT
    TOLO, H
    KOISTINEN, J
    KRUSIUS, T
    JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 139 (02) : 265 - 270
  • [7] Development of a flow cytometer-based in vitro compartmentalization screening platform for directed protein evolution
    Wirtz, Georgette
    Pitzler, Christian
    Vojcic, Ljubica
    Martinez, Ronny
    Schwaneberg, Ulrich
    NEW BIOTECHNOLOGY, 2014, 31 : S149 - S149
  • [8] Development of a flow cytometer-based in vitro compartmentalization screening platform for directed protein evolution
    Wirtz, Georgette
    Pitzler, Christian
    Vojcic, Ljubica
    Martinez, Ronny
    Schwaneberg, Ulrich
    NEW BIOTECHNOLOGY, 2014, 31 : S149 - S149
  • [9] Radiation biodosimetry with the cytokinesis-block micronucleus assay on the ImageStreamX® imaging flow cytometer
    Beaton-Green, Lindsay
    Rodrigues, Matthew A.
    Wilkins, Ruth C.
    MEDICAL PHYSICS, 2017, 44 (08) : 4381 - 4381
  • [10] A flow cytometer-based whole cell screening toolbox for directed hydrolase evolution through fluorescent hydrogels
    Luelsdorf, Nina
    Pitzler, Christian
    Biggel, Michael
    Martinez, Ronny
    Vojcic, Ljubica
    Schwaneberg, Ulrich
    CHEMICAL COMMUNICATIONS, 2015, 51 (41) : 8679 - 8682