Pseudoendoleak - Residual intrasaccular contrast after endovascular stent-graft repair

被引:0
|
作者
Lee, WA [1 ]
Rubin, GD [1 ]
Johnson, BL [1 ]
Arko, F [1 ]
Fogarty, TJ [1 ]
Zarins, CK [1 ]
机构
[1] Stanford Univ, Div Vasc Surg, Stanford, CA 94305 USA
关键词
abdominal aortic aneurysm; endoleak; computed tomography; duplex ultrasound; contrast medium;
D O I
10.1583/1545-1550(2002)009<0119:PRICAE>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To present a unique demonstration of postoperative perigraft contrast masquerading as an endoleak following endovascular abdominal aortic aneurysm (AAA) repair. Case Report., A 66-year-old man underwent endovascular stent-graft repair of a 4.6-cm infrarenal AAA. The procedure was uncomplicated, and intraoperative completion angiography demonstrated good proximal and distal fixation of the stent-graft without an endoleak. A spiral computed tomographic (CT) angiogram obtained on postoperative day 2 revealed a large amount of extrastent contrast along the posterior aspect of the aneurysm sac. This defect had the appearance of an endoleak, but it was also present on the non-contrast images. A color-flow duplex examination performed on the same day showed a widely patent stent-graft with no evidence of extrastent flow. Conclusions: Contrast trapped in the aneurysm sac during endovascular aneurysm repair may be misinterpreted as an endoleak on postprocedural CT scans. "Pseudoendoleaks" can be distinguished from true endoleaks by examination of prebolus, noncontrast CT images, as well as by duplex ultrasound scanning.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 50 条
  • [1] Endovascular aneurysm repair with the talent stent-graft
    Cowie, AG
    Ashleigh, RJ
    England, RE
    McCollum, CN
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (08) : 1011 - 1016
  • [2] Endovascular Stent-Graft Repair of Aortobronchial Fistulas
    Kawaharada, Nobuyoshi
    Kurimoto, Yoshihiko
    Ito, Toshiro
    Uehara, Mayuko
    Maeda, Toshiyuki
    Koyanagi, Tetsuya
    Muraki, Satoshi
    Watanabe, Atsushi
    Higami, Tetsuya
    ANNALS OF THORACIC SURGERY, 2012, 94 (02): : 524 - 529
  • [3] Stent-graft migration after endovascular repair of abdominal aortic aneurysm
    Kalliafas, S
    Albertini, JN
    Macierewicz, J
    Yusuf, SW
    Whitaker, SC
    Davidson, I
    Hopkinson, BR
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (06) : 743 - 747
  • [4] Stent-Graft Removal and Extra-Anatomical Bypass for the Treatment of Stent-Graft Infection after Endovascular Aneurysm Repair
    Kuriyama, Naoya
    Koya, Atsuhiro
    Kikuchi, Shinsuke
    Uchida, Daiki
    Azuma, Nobuyoshi
    ANNALS OF VASCULAR DISEASES, 2022, 15 (01) : 72 - 76
  • [5] Endovascular Treatment of Late in—Stent-Graft Dissection After Thoracic Endovascular Aneurysm Repair
    Ivan Vulev
    Andrej Klepanec
    Tibor Balázs
    Marián Holomáň
    CardioVascular and Interventional Radiology, 2011, 34 : 864 - 867
  • [6] Endovascular stent-graft repair with a flexible stent-graft and a simple applicator prepared from a syringe
    Moriyama, Y
    Iguro, Y
    Yotsumoto, G
    Watanabe, S
    Yamamoto, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (03): : 620 - 621
  • [7] Endovascular stent-graft repair of failed endovascular abdominal aortic aneurysm repair
    Baril, Donald T.
    Silverberg, Daniel
    Ellozy, Sharif H.
    Carroccio, Alflo
    Jacobs, Tikva S.
    Sachdev, Ulka
    Teodorescu, Victoria J.
    Lookstein, Robert A.
    Marin, Michael L.
    ANNALS OF VASCULAR SURGERY, 2008, 22 (01) : 30 - 36
  • [8] Re: Ureteroarterial fistula: Endovascular repair with a Stent-Graft
    Kato, N
    Kawaguchi, T
    Kondo, T
    Hasegawa, Y
    Ishida, A
    Sakuma, A
    Kawamura, J
    Yada, I
    Takeda, K
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 25 (02) : 158 - 159
  • [9] Endovascular stent-graft repair of descending aortic aneurysm
    Soeparwata, R
    Vestring, T
    Reimer, P
    Etz, C
    Hammel, D
    Schmitt, C
    Scheld, HH
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (02): : 207 - 207
  • [10] Endovascular stent-graft repair of ruptured aortic aneurysms
    Scharrer-Pamler, R
    Kotsis, T
    Kapfer, X
    Görich, J
    Sunder-Plassmann, L
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (03) : 447 - 452