Experimental Measurement and Numerical Validation of Bone Cement Mantle Strains of an In Vitro Hip Replacement Using Optical FBG Sensors

被引:8
|
作者
Ramos, A. [1 ]
Schiller, M. W. [2 ]
Abe, I. [2 ]
Lopes, P. A. [2 ]
Simoes, J. A. [1 ]
机构
[1] Univ Aveiro, Dept Mech Engn, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Phys, P-3810193 Aveiro, Portugal
关键词
Hip; Cement strain; Finite element analysis; Optical fiber Bragg grating sensors; experimental procedure; cement temperature; FINITE-ELEMENT; FIXATION; FAILURE; INITIATION; THICKNESS; DAMAGE;
D O I
10.1007/s11340-012-9596-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Experimental pre-clinical tests associated with numeric models of cemented implants are important for screening of new implants in the market. The aim of this study was to measure strain profiles and maximum temperature polymerization inside a cement mantle of an in vitro cemented hip reconstruction using optical fiber Bragg grating (FBG) sensors. For this purpose, a hip femoral prosthesis was instrumented with 12 FBG sensors, three in each aspect of the femur, anterior, posterior, medial and lateral. These were positioned at the proximal, middle and distal part of the cement mantle relatively to the stem. Another sensor was placed in the lateral-proximal region of the mantle to measure the maximum temperature of cement polymerization. The strains measured were compared with those obtained with a Finite Element model, both for quaistatic mechanical loading. The results show that the experimental technique used can measure strains inside the cement mantle with good correlation, R-2 = 0.970, with the numerical model results. The results present a maximum temperature of polymerization around 110 degrees C inside of cement at proximal region. It was also observed strain concentration in lateral aspect of the femur in polymerization process. The procedure hereby explained can be used to improve experimental pre-clinical tests to measure the strain distribution inside the cement mantle as well as residual strain and temperature variation along with time, as a result of the curing process of cement.
引用
收藏
页码:1267 / 1274
页数:8
相关论文
共 4 条
  • [1] Experimental Measurement and Numerical Validation of Bone Cement Mantle Strains of an In Vitro Hip Replacement Using Optical FBG Sensors
    A. Ramos
    M. W. Schiller
    I. Abe
    P. A. Lopes
    J. A. Simões
    Experimental Mechanics, 2012, 52 : 1267 - 1274
  • [2] BONE STRAIN ASSESSMENT IN A SECTION OF A CEMENTED HIP REPLACEMENT: NUMERICAL AND EXPERIMENTAL VALIDATION
    Ramos, Antonio
    Relvas, Carlos
    Completo, Antonio
    Simoes, Jose A.
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [3] In vitro analysis of the cement mantle of femoral hip implants: development and validation of a CT-scan based measurement tool
    Scheerlinck, T
    de Mey, J
    Deklerck, R
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) : 698 - 704
  • [4] Experimental validation of non-contacting measurement method using LED-optical displacement sensors for vibration stress of small-bore piping
    Maekawa, Akira
    Takahashi, Tsuneo
    Tsuji, Takashi
    Noda, Michiyasu
    MEASUREMENT, 2015, 71 : 1 - 10