Compression Screw Fixation of the Syndesmosis

被引:10
|
作者
Darwish, Husam H. [2 ]
Glisson, Richard R. [1 ]
DeOrio, James K. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Orthopaed Surg, Durham, NC 27704 USA
[2] King Abdulaziz Univ, Dept Orthoped Surg, Jeddah 21413, Saudi Arabia
关键词
Ankle; Syndesmosis; Screw Fixation; Compression; TIBIOFIBULAR SYNDESMOSIS; ANKLE SYNDESMOSIS; STAINLESS-STEEL; FRACTURES; CADAVER; INJURY; CONSTRUCT; CORTICES; JOINT; MODEL;
D O I
10.3113/FAI.2012.0893
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Screw fixation of syndesmotic injuries facilitates ligament healing and restoration of ankle stability, but little information regarding screw performance is available. This study quantified the reduction obtained with three common 2-screw configurations using different methods of reduction and novel methods of subsequently provoking and measuring diastasis. Methods: Seven fresh-frozen lower extremities were subjected to 100 N medial and lateral tibia loads with the talus restrained. Tibia displacement, indicative of ankle clear space, was recorded. The syndesmosis and distal interosseous ligament were disrupted and measurements repeated. A pressure sensor was inserted into the syndesmosis and three 2-screw fixation methods were evaluated in each specimen: 3.5-mm screws engaging both fibula cortices and the lateral tibial cortex, inserted while using a clamp to achieve syndesmosis reduction; 3.5-mm lag screws engaging both tibia cortices; and 4.5-mm lag screws engaging both tibia cortices. One thousand 100 N medial and lateral loads were applied and clear space and syndesmosis compression were quantified every 100 cycles. Results: Normal ankle clear space averaged 1.98 mm and increased to 3.02 mm after syndesmosis disruption. Fixation decreased the clear space to 1.36 mm, 1.22 mm, and 1.19 mm for the 3.5-mm tricortical, 3.5-mm lag, and 4.5-mm lag screws, respectively, remaining steady throughout cyclic loading. Syndesmosis compression dropped markedly from 61N to 23 N on clamp release after tricortical screw insertion. The 3.5-mm and 4.5-mm lag screws exerted 112 N and 131 N, respectively, after insertion, and maintained compression several-fold greater than the tricortical screws during cyclic loading. No difference was demonstrable between the two lag screw sizes. Conclusion: While all screw configurations successfully reduced ankle clear space, syndesmosis reduction was more effectively maintained by lag screws than by tricortical screws inserted with clamp reduction. The transient nature of compression achieved by the reduction clamp suggests that use of lag screws for this application may more reliably maintain syndesmosis reduction in vivo. Clinical Relevance: Optimizing reduction of syndesmosis injuries is critical for favorable outcomes. This study offers concrete information on screw performance in this application.
引用
收藏
页码:893 / 899
页数:7
相关论文
共 50 条
  • [1] Comment on "Compression Screw Fixation of the Syndesmosis"
    Er, Mehmet Serhan
    Eroglu, Mehmet
    Altinel, Levent
    FOOT & ANKLE INTERNATIONAL, 2013, 34 (04) : 612 - 612
  • [2] Comment on "Compression Screw Fixation of the Syndesmosis" Response
    DeOrio, James K.
    FOOT & ANKLE INTERNATIONAL, 2013, 34 (04) : 613 - 613
  • [3] Revision of Syndesmosis Screw Fixation
    Bafna, Kunaal R.
    Jordan, Richard
    Yatsonsky, David
    Dick, Steven
    Liu, Jiayong
    Ebraheim, Nabil A.
    FOOT & ANKLE SPECIALIST, 2020, 13 (02) : 138 - 143
  • [4] Novel Elastic Syndesmosis Hook Plate Fixation Versus Routine Screw Fixation for Syndesmosis Injury
    Xian, Hang
    Miao, Jianyun
    Zhou, Qiankun
    Lian, Kejian
    Zhai, Wenliang
    Liu, Qingjun
    JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (01): : 65 - 68
  • [5] Outcome after fixation of ankle fractures with an injury to the syndesmosis THE EFFECT OF THE SYNDESMOSIS SCREW
    Hamid, N.
    Loeffler, B. J.
    Braddy, W.
    Kellam, J. F.
    Cohen, B. E.
    Bosse, M. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (08): : 1069 - 1073
  • [6] Bioabsorbable Screw Fixation of the Syndesmosis in Unstable Ankle Injuries
    Ahmad, Jamal
    Raikin, Steven M.
    Pour, Aidin E.
    Haytmanek, Craig
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (02) : 99 - 105
  • [7] A Comparison of Screw Fixation and Suture-Button Fixation in a Syndesmosis Injury in an Ankle Fracture
    Kim, Jung-Han
    Gwak, Heui-Chul
    Lee, Chang-Rack
    Choo, Hye-Jeung
    Kim, Jeon-Gyo
    Kim, Dae-Yoo
    JOURNAL OF FOOT & ANKLE SURGERY, 2016, 55 (05): : 985 - 990
  • [8] Comparison of screw fixation with elastic fixation methods in the treatment of syndesmosis injuries in ankle fractures
    Seyhan, Mustafa
    Donmez, Ferdi
    Mahirogullari, Mahir
    Cakmak, Selami
    Mutlu, Serhat
    Guler, Olcay
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S19 - S23
  • [9] Syndesmosis fixation: A comparison of three and four cortices of screw fixation without hardware removal
    Moore, Joel A., Jr.
    Shank, John R.
    Morgan, Steven J.
    Smith, Wade R.
    FOOT & ANKLE INTERNATIONAL, 2006, 27 (08) : 567 - 572
  • [10] Tibiofemoral syndesmosis injury treated by temporary screw fixation and ligament repair
    Steinmetz, S.
    Puliero, B.
    Brinkert, D.
    Meyer, N.
    Adam, P.
    Bonnomet, F.
    Ehlinger, M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (08) : 1069 - 1073