Theoretical analysis and design of fire protection and thermal insulation of parallel wire or strand cables

被引:1
|
作者
Ouyang, Ping [1 ]
Chen, Boxuan [2 ,3 ,4 ]
Shen, Quanxi [2 ,3 ,4 ]
Zhu, Wanxu [2 ,3 ,4 ]
机构
[1] Guangxi Univ, Nanning, Guangxi, Peoples R China
[2] Guilin Univ Technol, Collaborat Innovat Ctr Explorat Hidden Nonferrous, 12 Jiangan Rd, Guilin 541004, Guangxi, Peoples R China
[3] Guilin Univ Technol, Guangxi Engn Res Ctr Intelligent Struct Mat, Guilin, Guangxi, Peoples R China
[4] Guilin Univ Technol, Guangxi Key Lab Geotech Mech & Engn, Guilin, Guangxi, Peoples R China
关键词
Parallel wire cable; fire protection design; temperature history; temperature field; section factor; STEEL CABLES; MECHANICAL-PROPERTIES; BRIDGES;
D O I
10.1177/16878132221127830
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a transient heat flow model has been established for parallel wire or strand cables at high temperature by employing the lumped thermal mass approach, and the numerical solution of the surface temperature as a function of time in each layer of the steel wire or strand inside the cable was calculated. Accuracy of the theoretical method is verified through uniform heating test of 73 phi 15.7 mm steel strand cable. The results calculated show that temperature field inhomogeneity of cable section is overestimation on the condition that heat conduction inside the cable is not considered. Considering heat conduction or not, the maximum temperature difference of the core steel stand at the same time point is 373 . Unprotected 73 phi 15.7 mm cable is damaged in only 12 min in UL1709 fire, and arrangement of fire protection layer around cable can effectively retard the temperature rise of cable surface. The experimental results are in good agreement with the theoretical calculation values in early stage of fire, and the temperature difference between the two is within 10%. Besides, the numerical calculations were analyzed in accordance with the fire protection requirements limiting the surface temperature of cables. It was observed that the minimum thickness of the fire protection layer required to meet the PTI DC45.1-12 standard was linearly related to the numerical value of the section factor of the outermost layer of steel wires or steel strands in the equivalent model, and the slope of the function was approximately equal to the conduction coefficient of fire protection layer, as the cable was subjected to fire for 30 min. Further, based on this, a simple method was proposed to calculate the minimum thickness of the fire protection layer for parallel wire or strand cables.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] FATIGUE RESISTANCE ANALYSIS OF PARALLEL WIRE STRAND CABLES BASED ON STATISTICAL THEORY OF EXTREME.
    Matsukawa, Akio
    Kamei, M.
    Fukui, Y.
    Sasaki, Y.
    Stahlbau, 1985, 54 (11) : 326 - 335
  • [2] FATIGUE STRENGTH ANALYSIS OF PARALLEL WIRE STRAND CABLES BASED ON STATISTICAL THEORY OF EXTREMES (PART 2).
    Matsukawa, A.
    Kamei, M.
    Mizoguchi, T.
    Sasaki, Y.
    Stahlbau, 1988, 57 (07) : 205 - 210
  • [3] Bending-Induced Stresses in Parallel Seven-Wire Strand Stay Cables
    Lin, Qian
    Tabatabai, Habib
    JOURNAL OF BRIDGE ENGINEERING, 2024, 29 (11)
  • [4] THERMAL ANALYSIS OF CABLES THROUGH FIRE-STOPS.
    Muhleman, C.E.
    American Society of Mechanical Engineers (Paper), 1979,
  • [5] Design FINER as a Fire Detection and Overcurrent Protection on Electrical Installation Cables
    Siregar, Ramdhan Halid
    Hasan, Hafidh
    Sakti, Bima
    2018 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICELTICS): INTELLIGENT DEVICES AND COMPUTING FOR ACCELERATING INDUSTRY 4.0 AND ENRICHING SMART SOCIETIES, 2018, : 173 - 178
  • [6] Theoretical research on insulation thickness design of 66 kV AC submarine cables
    Zhao, Yuantao
    Shan, Qianyu
    Zhao, Xuetong
    Wang, Zerui
    Wang, Can
    Yang, Lijun
    Liao, Ruijin
    2022 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP 2022), 2022, : 554 - 559
  • [7] Study on the Fire Protection Technologies for External Thermal Insulation System of the Buildings
    Cui, Yanqiu
    Peng, Yunlong
    Luo, Cailing
    Progress in Industrial and Civil Engineering III, Pt 1, 2014, 638-640 : 1646 - 1649
  • [8] External doubleleaf masonry walls - Effects of the thermal insulation on fire protection
    Hahn, Christiane
    MAUERWERK, 2011, 15 (03) : 132 - 138
  • [9] Fire and Blast Protection for Multi-Strand Stay Cables of Rod El Farag Axis Bridge
    Zou, Yiqing
    Qin, Lei
    Sun, Limin
    Pang, Ruijian
    Chen, Lin
    STRUCTURAL ENGINEERING INTERNATIONAL, 2023, 33 (01) : 179 - 182
  • [10] A THERMAL-ANALYSIS OF CABLES THROUGH FIRE-STOPS
    MUHLEMAN, CE