Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy

被引:55
|
作者
Kausch, C
Schreiber, B
Kreuder, F
Schmidt, R
Dössel, O
机构
[1] Philips Res Labs, D-22335 Hamburg, Germany
[2] Univ Hamburg Hosp, Clin Radiol, Dept Radiotherapy, D-20246 Hamburg, Germany
[3] Univ Karlsruhe, Inst Biomed Engn, D-76128 Karlsruhe, Germany
关键词
portal images; metal plate/phosphor screens; image quality; monte carlo simulation; MTF(f); NPS(f); DQE(f);
D O I
10.1118/1.598727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The imaging performance of metal plate/phosphor screens which are used for the creation of portal images in radiotherapy is investigated by using Monte Carlo simulations. To this end the modulation transfer function, the noise power spectrum and the detective quantum efficiency [DQE(f)] are calculated for different metals and phosphors and different thicknesses of metal and phosphor for a range of spatial resolutions. The interaction of x-rays with the metal plate/phosphor screen is modeled with the EGS4 electron gamma shower code. Optical transport in the phosphor is modeled by simulating scattering and reabsorption events of individual optical photons. It is shown that metals with a high atomic number perform better than lighter metals in maximizing the DQE(f). It is furthermore shown that the DQE(f) for the metal plate/phosphor screen alone is nearly x-ray quantum absorption limited up to spatial frequencies of 0.4 cycles/mm. In addition, it is argued that the secondary quantum sink of optical photons imposed by the optical chain (mirror, lenses and video camera) leads to a significant degradation of the signal-to-noise ratio at spatial frequencies which are most important for successful registration of portal images. Therefore, the conclusion is that a replacement of the optical chain by a flat array of photodiodes placed directly under the phosphor will lead to a substantial improvement in image quality of portal images. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01710-1].
引用
收藏
页码:2113 / 2124
页数:12
相关论文
共 50 条
  • [1] MONTE-CARLO OPTIMIZATION OF METAL PHOSPHOR SCREENS AT MEGAVOLTAGE ENERGIES
    RADCLIFFE, T
    BARNEA, G
    WOWK, B
    RAJAPAKSHE, R
    SHALEV, S
    MEDICAL PHYSICS, 1993, 20 (04) : 1161 - 1169
  • [2] Modeling granular phosphor screens by Monte Carlo methods
    Liaparinos, Panagiotis F.
    Kandarakis, Ioannis S.
    Cavouras, Dionisis A.
    Delis, Harry B.
    Panayiotakis, George S.
    MEDICAL PHYSICS, 2006, 33 (12) : 4502 - 4514
  • [3] Monte Carlo simulations in radiotherapy dosimetry
    Pedro Andreo
    Radiation Oncology, 13
  • [4] Monte Carlo simulations in radiotherapy dosimetry
    Andreo, Pedro
    RADIATION ONCOLOGY, 2018, 13
  • [5] Monte Carlo Simulations of Bremsstrahlung Production in a Carbon Target for Imaging in Radiotherapy
    Ritter, Ina
    Durst, Juergen
    Michel, Thilo
    Schemm, Sebastian
    Suft, Gabriele
    Anton, Gisela
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4303 - 4305
  • [6] Monte Carlo modeling of storage phosphor plate readouts
    Fasbender, R
    Li, H
    Winnacker, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 512 (03): : 610 - 618
  • [7] The Monte Carlo evaluation of noise and resolution properties of granular phosphor screens
    Liaparinos, P. F.
    Kandarakis, I. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (04): : 859 - 874
  • [8] The imaging performance of compact Lu2O3:Eu powdered phosphor screens: Monte Carlo simulation for applications in mammography
    Liaparinos, P. F.
    Kandarakis, I. S.
    MEDICAL PHYSICS, 2009, 36 (06) : 1985 - 1997
  • [9] A Monte Carlo study of the impact of phosphor optical properties on EPID imaging performance
    Shi, Mengying
    Myronakis, Marios
    Hu, Yue-Houng
    Morf, Daniel
    Rottmann, Joerg
    Berbeco, Ross
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (16):
  • [10] Monte Carlo simulations of kV imaging beams and methods of managing imaging doses to radiotherapy patients
    Ding, G.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S292 - S293