Effects of magnetic resonance Imaging on cardiac pacemakers and electrodes

被引:179
|
作者
Achenbach, S [1 ]
Moshage, W [1 ]
Diem, B [1 ]
Bieberle, T [1 ]
Schibgilla, V [1 ]
Bachmann, K [1 ]
机构
[1] UNIV ERLANGEN NURNBERG,INST BIOMED TECHN,D-91054 ERLANGEN,GERMANY
关键词
D O I
10.1016/S0002-8703(97)70083-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In phantom studies we investigated the effects of magnetic resonance imaging (MRI) on pacemakers and electrodes. Twenty-five electrodes were exposed to MRI in a 1.5T scanner with continuous registration of the temperature at the electrode tip. Eleven pacemakers (five single chamber and six dual chamber) were exposed to MRI. Pacemaker output was monitored to detect malfunction in VOO/DOO and WI/DDD modes, A temperature increase at the electrode tip of up to 63.1 degrees C was observed during 90 seconds of scanning. In seven electrodes the temperature increase exceeded 15 degrees C. Although no pacemaker malfunctions were observed in asynchronous pacing mode (VOO/D00), inhibition and rapid pacing were observed during spin-echo imaging if the pacemakers were set to VVI or DDD mode. Pacemaker function was not impaired during scanning with gradient-echo sequences. Next to pacemaker dysfunction, electrode heating has to be considered a possible adverse effect when exposing patients with pacemakers to MRI.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 50 条
  • [1] Magnetic resonance imaging in patients with cardiac pacemakers
    Sommer, T
    Naehle, CP
    Schild, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (03) : 561 - 562
  • [2] EFFECTS OF NUCLEAR-MAGNETIC-RESONANCE IMAGING ON CARDIAC-PACEMAKERS
    LAUCK, G
    VONSMEKAL, A
    WOLKE, S
    SEELOS, KC
    JUNG, W
    MANZ, M
    LUDERITZ, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (08): : 1549 - 1555
  • [3] Magnetic resonance imaging in patients with cardiac pacemakers - Reply
    Martin, ET
    Coman, JA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (03) : 562 - 562
  • [4] Uses and potential for cardiac magnetic resonance imaging in patients with cardiac resynchronisation pacemakers
    Koshy, Aaron
    Witte, Klaus
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (06) : 445 - 450
  • [5] Implantable pulse generators (pacemakers) and electrodes: Safety in the magnetic resonance imaging scanner environment
    Bhachu, DS
    Kanal, E
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (01) : 201 - 204
  • [6] Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers
    Gimbel, JR
    Johnson, D
    Levine, PA
    Wilkoff, BL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (06): : 913 - 919
  • [7] Can cardiac pacemakers and magnetic resonance imaging systems co-exist?
    Martin, ET
    EUROPEAN HEART JOURNAL, 2005, 26 (04) : 325 - 327
  • [8] NUCLEAR MAGNETIC-RESONANCE IMAGING OF EXTERNAL AND IMPLANTABLE CARDIAC-PACEMAKERS
    FETTER, J
    ARAM, G
    HOLMES, D
    HAYES, D
    JULSRUD, P
    GIBBONS, R
    GRAY, J
    CHEST, 1983, 84 (03) : 345 - 345
  • [9] Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs
    Shinbane, Jerold S.
    Colletti, Patrick M.
    Shellock, Frank G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [10] Interference with cardiac pacemakers by magnetic resonance imaging:: Are there irreversible changes at 0.5 Tesla?
    Vahlhaus, C
    Sommer, T
    Lewalter, T
    Schimpf, R
    Schumacher, B
    Jung, W
    Lüderitz, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (04): : 489 - 495