Impact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation

被引:3
|
作者
Hong, Sung-Jin [1 ]
Kim, Byeong-Keuk [2 ,3 ]
Shin, Dong-Ho [2 ,3 ]
Kim, Jung-Sun [2 ,3 ]
Ko, Young-Guk [2 ,3 ]
Choi, Donghoon [2 ,3 ]
Jang, Yangsoo [2 ,3 ,4 ]
Hong, Myeong-Ki [2 ,3 ,4 ]
机构
[1] Inje Univ, Coll Med, Sanggye Paik Hosp, Dept Internal Med,Div Cardiol, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol, Seoul 03722, South Korea
[3] Yonsei Univ, Coll Med, Cardiovasc Inst, Seoul 03722, South Korea
[4] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 03722, South Korea
关键词
Drug-eluting stent; intravascular ultrasound; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND ANALYSIS; ADVERSE CLINICAL-OUTCOMES; STRUT COVERAGE; FOLLOW-UP; APPOSITION; THROMBOSIS; PREDICTORS; MECHANISMS;
D O I
10.3349/ymj.2015.56.6.1538
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound (VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent (DES) implantation. Materials and Methods: The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VH-IVUS and follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core (NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percent malapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. Results: Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9 +/- 19.0, 7.9 +/- 9.6, 63.8 +/- 33.8, and 16.5 +/- 12.4 mm(3), respectively. At 6.3 +/- 3.1 months post-intervention, percent malapposed and uncovered struts were 0.8 +/- 2.5% and 15.3 +/- 16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts (r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associated with percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independent predictor of late stent malapposition on multivariate analysis (beta=1.12, p=0.002). There were no significant correlations between pre-intervention plaque composition and percent uncovered struts. Conclusion: Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DES implantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [1] Impact of late stent malapposition after drug-eluting stent implantation on long-term clinical outcomes
    Im, Eui
    Lee, Seung-Yul
    Hong, Sung-Jin
    Ahn, Chul-Min
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    ATHEROSCLEROSIS, 2019, 288 : 118 - 123
  • [2] Clinical impact of in-stent late loss after drug-eluting coronary stent implantation
    Moreno, Raúl
    Fernandez, Cristina
    Sanchez-Recalde, Angel
    Galeote, Guillermo
    Calvo, Luis
    Alfonso, Fernando
    Hernandez, Rosana
    Sanchez-Aquino, Rosa
    Angiolillo, Dominick J.
    Villarreal, Sergio
    Macaya, Carlos
    Lopez-Sendon, Jose L.
    EUROPEAN HEART JOURNAL, 2007, 28 (13) : 1583 - 1591
  • [3] Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
    Hassan, Ayman K. M.
    Bergheanu, Sandrin C.
    Stijnen, Theo
    van der Hoeven, Bas L.
    Snoep, Jaapjan D.
    Plevier, Josepha W. M.
    Schalij, Martin J.
    Jukema, J. Wouter
    EUROPEAN HEART JOURNAL, 2010, 31 (10) : 1172 - 1180
  • [4] The Impact of Intravascular Ultrasound for Late Stent Thrombosis after Drug-Eluting Stent Implantation
    Lee, Kyounghoon
    Yoon, Junghan
    Youn, Young-Jin
    Kim, Seong-Yoon
    Lee, Jun Won
    Kim, Jang-Young
    Lee, Seung-Hwan
    Choe, Kyung-Hoon
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (9A): : 113B - 113B
  • [5] Relationship between Stent Malapposition and Incomplete Neointimal Coverage after Drug-Eluting Stent Implantation
    Kim, Byeong-Keuk
    Hong, Myeong-Ki
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (03) : 270 - 277
  • [6] Incidence and characteristics of coronary aneurysm after drug-eluting stent implantation
    Rha, Seung-Woon
    Wani, Sunil P.
    Choi, Cheol Ong
    Suh, Soon Yong
    Kim, Eung Ju
    Kim, Jin Won
    Park, Chang Gyu
    Seo, Hong Seog
    Oh, Dong Joo
    CIRCULATION, 2006, 114 (18) : 731 - 731
  • [7] Late stent malapposition after drug eluting stent implantation is related to high incidence of very late stent thrombosis
    Qian, J. Y.
    Zhang, F.
    Wu, H. Y.
    Fan, B.
    Wang, Q. B.
    Ge, L.
    Ge, J. B.
    EUROPEAN HEART JOURNAL, 2007, 28 : 328 - 328
  • [8] Late stent malapposition after drug eluting stent implantation is, related to high incidence of very late stent thrombosis
    Qian, Juying
    Zhang, Feng
    Wu, Hongyi
    Fan, Bing
    Ge, Lei
    Ge, Junbo
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 192L - 192L
  • [9] Coronary aneurysm after drug-eluting stent implantation
    Paulista, Paulo Paredes
    Dagola Paulista, Paulo Henrique
    Centemero, Marinella Patrizia
    Feres, Fausto
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2008, 23 (01): : 126 - 128
  • [10] Coronary aneurysm after drug-eluting stent implantation
    Bagga, Shiv
    Sharma, Yash Paul
    Talwar, Kewal K.
    HEART ASIA, 2011, 3 (01) : 37 - 37