The use of point defects in digital radiography

被引:1
|
作者
Spaeth, JM [1 ]
机构
[1] Univ Gesamthsch Paderborn, Dept Phys, D-33095 Paderborn, Germany
来源
RADIATION EFFECTS AND DEFECTS IN SOLIDS | 2001年 / 154卷 / 3-4期
关键词
radiation defects; spatial correlation of defects; X-ray storage phosphors; photostimulated luminescence;
D O I
10.1080/10420150108214064
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Colour centres in alkali halides such as F centres and H or V-K centres have been studied intensely for decades but have hardly found any applications. However, in activator-doped halides their generation mechanisms upon irradiation with X-rays, their room temperature stability and photostimulated recombination processes are the basis of important applications in digital radiography, which has recently become commercially available. An overview is given of the present understanding of the point defect mechanisms in the commercially used X-ray storage phosphor BaFBr:EU2+ and its shortcomings. Further developments in BaFBr-based X-ray storage phosphors are discussed. Promising cubic Xray storage phosphor materials with high figures of merit and potentially higher spatial resolution, such as RbBr:Ga+, CsBr:Ga+, RbBr:EU2+ nd CsBr:EU2+ have recently been studied in detail and an overview of the generation and recombination mechanisms of the electron and hole trap centres active in the information storage and read-out processes is presented, Finally, first results are shown of the use of glass ceramics as potential new storage material in particular for high-energy X-rays.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 50 条
  • [1] Digital radiography for the inspection of small defects
    Blakeley, B
    Spartiotis, K
    [J]. INSIGHT, 2006, 48 (02) : 109 - 112
  • [2] DIGITAL RADIOGRAPHY PINPOINTS CASTING DEFECTS AUTOMATICALLY
    ISAACSON, BG
    KROHN, B
    [J]. MATERIALS EVALUATION, 1987, 45 (08) : 884 - 885
  • [3] Potential for fraudulent use of digital radiography
    Tsang, A
    Sweet, D
    Wood, RE
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1999, 130 (09): : 1325 - +
  • [4] THE USE OF DIGITAL RADIOGRAPHY TO MEASURE FLOW
    FREY, GD
    VUJIC, I
    ROSS, P
    [J]. MEDICAL PHYSICS, 1983, 10 (05) : 733 - 733
  • [5] USE OF DIGITAL RADIOGRAPHY SYSTEM FOR QUANTITATIVE DIGITAL AUTORADIOGRAPHY
    ALBRIGHT, RE
    SUDDARTH, SA
    FRAM, EK
    HARBURY, OL
    DRAYER, BP
    PUTMAN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1984, 19 (05) : S28 - S28
  • [6] DIGITAL RADIOGRAPHY FOR TARGET POINT EVALUATION IN STEREOTACTIC NEUROSURGERY
    FRODER, M
    SEITZER, D
    BUREN, G
    DIECKMANN, G
    [J]. APPLIED NEUROPHYSIOLOGY, 1983, 46 (1-4) : 206 - 210
  • [7] The Use of Digital Side Markers (DSMs) and Cropping in Digital Radiography
    Hayre, Christopher M.
    Blackman, Shane
    Eyden, Alison
    Carlton, Kevin
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (02) : 234 - 242
  • [8] Characterization of Point Spread Functions of Indirect Digital Radiography Detectors
    Sechopoulos, I.
    Schmitz, A.
    Eberhard, J. W.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3130 - +
  • [9] Method for Determining the Point Spread Function for a Digital Radiography System
    A. K. Avakyan
    I. L. Dergacheva
    A. A. Elanchik
    D. Yu. Korovkin
    T. A. Krylova
    T. K. Lobzhanidze
    S. A. Polikhov
    V. P. Smirnov
    [J]. Atomic Energy, 2020, 127 : 310 - 315
  • [10] Method for Determining the Point Spread Function for a Digital Radiography System
    Avakyan, A. K.
    Dergacheva, I. L.
    Elanchik, A. A.
    Korovkin, D. Yu.
    Krylova, T. A.
    Lobzhanidze, T. K.
    Polikhov, S. A.
    Smirnov, V. P.
    [J]. ATOMIC ENERGY, 2020, 127 (05) : 310 - 315