Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

被引:5
|
作者
Wells, Jered R. [1 ,2 ]
Dobbins, James T., III [1 ,2 ,3 ,4 ,5 ]
机构
[1] Duke Univ, Med Ctr, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
[5] Duke Univ, Dept Phys, Durham, NC 27705 USA
基金
美国国家卫生研究院;
关键词
modulation transfer function (MTF); digital radiography; resolution; edge spread function; line spread function; DETECTIVE QUANTUM EFFICIENCY; IMAGE QUALITY CHARACTERIZATION; ACQUISITION DEVICES; SPREAD FUNCTION; SYSTEMS; MTF; NOISE; PERFORMANCE; LINE;
D O I
10.1118/1.4752442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the ID edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm(-1)) and approximate circular symmetry at frequencies below 4 mm(-1). While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm(-1). Slit measurement near 45 degrees revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm x 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm(-1)) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of ID test devices for MTF assessment make this a valuable technique for 2D MTF estimation. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4752442]
引用
收藏
页码:6148 / 6160
页数:13
相关论文
共 50 条
  • [1] Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems
    Fetterly, KA
    Hangiandreou, NJ
    Schueler, BA
    Ritenour, ER
    MEDICAL PHYSICS, 2002, 29 (05) : 913 - 921
  • [2] Method for determining the two-dimensional presampling modulation transfer function in digital radiography
    Båth, M
    Sund, P
    Månsson, LG
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 268 - 279
  • [3] TWO-DIMENSIONAL OPTICAL-PROCESSING USING ONE-DIMENSIONAL INPUT DEVICES
    PSALTIS, D
    PROCEEDINGS OF THE IEEE, 1984, 72 (07) : 962 - 974
  • [4] Two-Dimensional DOA Estimation Using One-Dimensional Search for Spherical Arrays
    HUANG Qinghua
    FENG Jiajun
    FANG Yong
    ChineseJournalofElectronics, 2019, 28 (06) : 1259 - 1264
  • [5] Two-Dimensional DOA Estimation Using One-Dimensional Search for Spherical Arrays
    Huang, Qinghua
    Feng, Jiajun
    Fang, Yong
    CHINESE JOURNAL OF ELECTRONICS, 2019, 28 (06) : 1259 - 1264
  • [6] One-Dimensional MODE Algorithm for Two-Dimensional Frequency Estimation
    Jian Li
    Petre Stoica
    Dunmin Zheng
    Multidimensional Systems and Signal Processing, 1997, 8 : 449 - 468
  • [7] One-dimensional MODE algorithm for two-dimensional frequency estimation
    Li, JA
    Stoica, P
    Zheng, DM
    MULTIDIMENSIONAL SYSTEMS AND SIGNAL PROCESSING, 1997, 8 (04) : 449 - 468
  • [8] One-dimensional mode algorithm for two-dimensional frequency estimation
    Zheng, DM
    Li, J
    Stoica, P
    1997 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS I - V: VOL I: PLENARY, EXPERT SUMMARIES, SPECIAL, AUDIO, UNDERWATER ACOUSTICS, VLSI; VOL II: SPEECH PROCESSING; VOL III: SPEECH PROCESSING, DIGITAL SIGNAL PROCESSING; VOL IV: MULTIDIMENSIONAL SIGNAL PROCESSING, NEURAL NETWORKS - VOL V: STATISTICAL SIGNAL AND ARRAY PROCESSING, APPLICATIONS, 1997, : 3981 - 3984
  • [9] Composition modulation in one-dimensional and two-dimensional chalcogenide semiconductor nanostructures
    Li, Honglai
    Wang, Xiao
    Zhu, Xiaoli
    Duan, Xiangfeng
    Pan, Anlian
    CHEMICAL SOCIETY REVIEWS, 2018, 47 (20) : 7504 - 7521
  • [10] One-dimensional sensor modulation transfer function, revisited
    Jain, Prateek
    APPLIED OPTICS, 2015, 54 (13) : D33 - D37