Robotic cholecystectomy: first experience with the new Senhance robotic system

被引:24
|
作者
Melling, Nathaniel [1 ]
Barr, Justin [2 ]
Schmitz, Robin [2 ]
Polonski, Adam [1 ]
Miro, Jameel [1 ]
Ghadban, Tarik [1 ]
Wodack, Karin [3 ]
Izbicki, Jakob [1 ]
Zani, Sabino [2 ]
Perez, Daniel [1 ,3 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Gen Visceral & Thorac Surg, Hamburg, Germany
[2] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
[3] Univ Med Ctr Hamburg Eppendorf, Dept Surg, Martinistr 52, D-20246 Hamburg, Germany
关键词
Robotic cholecystectomy; Robotic surgery; Senhance robotic system; TELELAP ALF-X; LAPAROSCOPIC CHOLECYSTECTOMY; SURGICAL SYSTEM; SURGERY; TRENDS;
D O I
10.1007/s11701-018-0877-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
This retrospective study was performed to evaluate the safety and feasibility of the new Senhance robotic system (Transenterix) for robotic cholecystectomy. Our series is the first experience with cholecystectomies utilizing this new platform. From May 2017 to August 2017, 20 robotic cholecystectomies were performed using the Senhance robotic system. Patients were between 23years and 78years of age, eligible for a laparoscopic procedure with general anesthesia, with no life-threatening co-morbidities that limited the subjects' life-expectancy to fewer than 12months. A retrospective chart review was performed for a variety of pre-, peri- and postoperative data including, but not limited to patient demographics, intraoperative complications and postoperative complications. 9 male and 11 female patients were included in this study. Median age was 39.5years (range 23-78); median BMI was 27.35kg/m(2) (range 22.8-48.3). Median docking time was 10min (range 2-26), and median operative time was 71.5min (range 34-197). Conversion to standard laparoscopy occurred in one case for lysis of extensive adhesions. There were no conversions to open technique. There were no intra- or post-operative complications noted. We report the first series of robotic cholecystectomies using the new Senhance system. Docking time and total operative time decreased significantly over the course of this series and did not plateau; console time did not change significantly. This study demonstrates the feasibility of utilizing this platform in performing minimally invasive cholecystectomies.
引用
收藏
页码:495 / 500
页数:6
相关论文
共 50 条
  • [1] Robotic cholecystectomy: first experience with the new Senhance robotic system
    Nathaniel Melling
    Justin Barr
    Robin Schmitz
    Adam Polonski
    Jameel Miro
    Tarik Ghadban
    Karin Wodack
    Jakob Izbicki
    Sabino Zani
    Daniel Perez
    Journal of Robotic Surgery, 2019, 13 : 495 - 500
  • [2] Robotic Inguinal Hernia Repair (TAPP)First Experience with the New Senhance™ Robotic System
    Schmitz, Robin
    Willeke, Frank
    Barr, Justin
    Scheidt, Michael
    Saelzer, Heike
    Darwich, Ibrahim
    Zani, Sabino
    Stephan, Dietmar
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2019, 34
  • [3] INITIAL EXPERIENCE OF NEW SENHANCE ROBOTIC SYSTEM IN UROLOGIC SURGERY
    Yuan, LunHsiang
    Huang, ShiWei
    Huang, Yuwen
    JOURNAL OF UROLOGY, 2020, 203 : E467 - E467
  • [4] Robotic colorectal surgery using the Senhance® robotic system: a single center experience
    N. E. Samalavicius
    A. Dulskas
    V. Janusonis
    V. Klimasauskiene
    V. Eismontas
    O. Deduchovas
    T. Janusonis
    R. Markelis
    E. Smolskas
    Techniques in Coloproctology, 2022, 26 : 437 - 442
  • [5] Robotic colorectal surgery using the Senhance® robotic system: a single center experience
    Samalavicius, N. E.
    Dulskas, A.
    Janusonis, V
    Klimasauskiene, V
    Eismontas, V
    Deduchovas, O.
    Janusonis, T.
    Markelis, R.
    Smolskas, E.
    TECHNIQUES IN COLOPROCTOLOGY, 2022, 26 (06) : 437 - 442
  • [6] Initial Experience With a New Robotic Surgical System for Cholecystectomy
    Aggarwal, Ravi
    Beatty, Jasmine Winter
    Kinross, James
    von Roon, Alexander
    Darzi, Ara
    Purkayastha, Sanjay
    SURGICAL INNOVATION, 2020, 27 (02) : 136 - 142
  • [7] Robotic surgery using Senhance® robotic platform: single center experience with first 100 cases
    Narimantas Evaldas Samalavicius
    Vinsas Janusonis
    Raimondas Siaulys
    Marius Jasėnas
    Olegas Deduchovas
    Raimondas Venckus
    Viktorija Ezerskiene
    Renata Paskeviciute
    Geda Klimaviciute
    Journal of Robotic Surgery, 2020, 14 : 371 - 376
  • [8] Robotic surgery using Senhance® robotic platform: single center experience with first 100 cases
    Samalavicius, Narimantas Evaldas
    Janusonis, Vinsas
    Siaulys, Raimondas
    Jasenas, Marius
    Deduchovas, Olegas
    Venckus, Raimondas
    Ezerskiene, Viktorija
    Paskeviciute, Renata
    Klimaviciute, Geda
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (02) : 371 - 376
  • [9] Robotic cholecystectomy using Senhance robotic platform versus laparoscopic conventional cholecystectomy: a propensity score analysis
    Samalavicius, Narimantas E.
    Kaminskas, Tadas
    Zidonis, Zygimantas
    Janusonis, Vinsas
    Deduchovas, Olegas
    Eismontas, Vitalijus
    Nausediene, Vaida
    Dulskas, Audrius
    ACTA CHIRURGICA BELGICA, 2022, 122 (03) : 160 - 163
  • [10] Editorial Comment: Robotic surgery using Senhance® robotic platform: single center experience with first 100 cases
    Faria, Eliney F.
    INTERNATIONAL BRAZ J UROL, 2020, 46 (04): : 659 - 660