Direct determination of benzodiazepines in biological fluids by restricted-access solid-phase microextraction

被引:79
|
作者
Mullett, WM [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac010747n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biocompatible solid-phase microextraction (SPME) fiber was prepared using an alkyl-diol-silica (ADS) restricted-access material as the SPME coating. The ADS-SPME fiber was able to simultaneously fractionate the protein component from a biological sample, while directly extracting several benzodiazepines, overcoming the present disadvantages of direct sampling in biological matrixes by SPME. The fiber was interfaced with an HPLC-UV system, and an isocratic mobile phase was used to desorb, separate, and quantify the extracted compounds. The calculated clonazepam, oxazepam, temazepam, nordazepam, and diazepam detection limits were 600, 750, 333, 100, and 46 ng/mL in urine, respectively. The method was confirmed to be linear over the range of 50050 50000 ng/mL with an average linear coefficient (R-2) value of 0.9918. The injection repeatability and intra-assay precision of the method were evaluated over 10 injections, resulting in a RSD of similar to6%. The ADS-SPME fiber was robust and simple to use, providing many direct extractions and subsequent determination of benzodiazepines in biological fluids.
引用
收藏
页码:1081 / 1087
页数:7
相关论文
共 50 条
  • [1] Determination of parathion in biological fluids by means of direct solid-phase microextraction
    E. Gallardo
    M. Barroso
    C. Margalho
    A. Cruz
    D. N. Vieira
    M. López-Rivadulla
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1717 - 1726
  • [2] Determination of parathion in biological fluids by means of direct solid-phase microextraction
    Gallardo, E.
    Barroso, M.
    Margalho, C.
    Cruz, A.
    Vieira, D. N.
    Lopez-Rivadulla, M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (06) : 1717 - 1726
  • [3] Determination of five benzodiazepines in aqueous solution and biological fluids using solid-phase microextraction with Carbowax™/DVB fiber coating
    Luo, Y
    Pan, L
    Pawliszyn, J
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (02) : 193 - 201
  • [4] Restricted-access nanoparticles for magnetic solid-phase extraction of steroid hormones from environmental and biological samples
    Ye, Lei
    Wang, Qing
    Xu, Jinping
    Shi, Zhi-guo
    Xu, Li
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1244 : 46 - 54
  • [5] Determination of Five Benzodiazepines in Aqueous Solution and Biological Fluids using Solid-Phase Microextraction with Carbowax[TM]/DVB Fiber Coating
    Luo, Y.
    Pan, L.
    Pawliszyn, J.
    Journal of Microcolumn Separation, 10 (02):
  • [6] Fast assay of angiotensin 1 from whole blood by cation-exchange restricted-access solid-phase microextraction
    Musteata, FM
    Walles, M
    Pawliszyn, J
    ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) : 231 - 237
  • [7] A new restricted access molecularly imprinted fiber for direct solid phase microextraction of benzodiazepines from plasma samples
    de Carvalho Abrao, Lailah Cristina
    Figueiredo, Eduardo Costa
    ANALYST, 2019, 144 (14) : 4320 - 4330
  • [8] Monitoring of drugs and metabolites in whole blood by restricted-access solid-phase microextraction coupled to liquid chromatography-mass spectrometry
    Walles, M
    Mullett, WM
    Pawliszyn, J
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1025 (01) : 85 - 92
  • [9] Simultaneous determination of barbiturates in human biological fluids by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry
    Iwai, M
    Hattori, H
    Arinobu, T
    Ishii, A
    Kumazawa, T
    Noguchi, H
    Noguchi, H
    Suzuki, O
    Seno, H
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 806 (01): : 65 - 73
  • [10] Solid-phase microextraction of monocyclic aromatic amines from biological fluids
    DeBruin, LS
    Josephy, PD
    Pawliszyn, JB
    ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1986 - 1992