Noninvasive estimation of the arterial input function in positron emission tomography imaging of cerebral blood flow

被引:39
|
作者
Su, Yi [1 ]
Arbelaez, Ana M. [2 ]
Benzinger, Tannmie L. S. [1 ]
Snyder, Abraham Z. [1 ]
Vlassenko, Andrei G. [1 ]
Mintun, Mark A. [3 ]
Raichle, Marcus E. [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, Dept Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Pediat, St Louis, MO 63110 USA
[3] Avid Radiopharmaceut, Philadelphia, PA USA
来源
关键词
arterial input function; PET; OXYGEN EXTRACTION FRACTION; AUTORADIOGRAPHIC METHOD; O-15; RADIOTRACERS; METABOLIC-RATE; NORMAL VALUES; DYNAMIC PET; BRAIN; VOLUME; WATER; PERFUSION;
D O I
10.1038/jcbfm.2012.143
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Positron emission tomography (PET) with O-15-labeled water can provide reliable measurement of cerebral blood flow (CBF). Quantification of CBF requires knowledge of the arterial input function (AIF), which is usually provided by arterial blood sampling. However, arterial sampling is invasive. Moreover, the blood generally is sampled at the wrist, which does not perfectly represent the AIF of the brain, because of the effects of delay and dispersion. We developed and validated a new noninvasive method to obtain the AIF directly by PET imaging of the internal carotid artery in a region of interest (ROI) defined by coregistered high resolution magnetic resonance angiography. An ROI centered at the petrous portion of the internal carotid artery was defined, and the AIF was estimated simultaneously with whole brain blood flow. The image-derived AIF (IDAIF) method was validated against conventional arterial sampling. The IDAIF generated highly reproducible CBF estimations, generally in good agreement with the conventional technique. Journal of Cerebral Blood Flow & Metabolism (2013) 33, 115-121; doi:10.1038/jcbfm.2012.143; published online 17 October 2012
引用
收藏
页码:115 / 121
页数:7
相关论文
共 50 条
  • [1] Noninvasive Positron Emission Tomography Imaging of Coronary Arterial Inflammation
    Abdelbaky A.
    Tawakol A.
    Current Cardiovascular Imaging Reports, 2011, 4 (1) : 41 - 49
  • [2] TRANSCUTANEOUS MEASUREMENT OF THE ARTERIAL INPUT FUNCTION IN POSITRON EMISSION TOMOGRAPHY
    LITTON, JE
    ERIKSSON, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 627 - 628
  • [3] IMAGING OF CEREBRAL BLOOD-FLOW AND METABOLISM IN AMBLYOPIA BY POSITRON EMISSION TOMOGRAPHY
    DEMER, JL
    VONNOORDEN, GK
    VOLKOW, ND
    GOULD, KL
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (04) : 337 - 347
  • [4] Cerebral blood flow measurement with positron emission tomography
    Powers, WJ
    CEREBRAL BLOOD FLOW: MECHANISMS OF ISCHEMIA, DIAGNOSIS AND THERAPY, 2002, 37 : 217 - 225
  • [5] NONINVASIVE ALTERNATIVES TO ARTERIAL BLOOD-SAMPLING IN POSITRON EMISSION TOMOGRAPHY
    HUTCHINS, GD
    VOTAW, JR
    FUNK, KM
    ROSENTHAL, MS
    KOEPPE, RA
    NICKLES, RJ
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P104 - P104
  • [6] Arterial input function sampling without surgery in rats for positron emission tomography molecular imaging
    Croteau, Etienne
    Poulin, Eric
    Tremblay, Sebastien
    Dumulon-Perreault, Veronique
    Sarrhini, Otman
    Lepage, Martin
    Lecomte, Roger
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (06) : 666 - 676
  • [7] NONINVASIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW CHANGE WITH (H2O)-O-15 AND POSITRON EMISSION TOMOGRAPHY USING A MECHANICAL INJECTOR AND A STANDARD ARTERIAL INPUT FUNCTION
    SADATO, N
    YONEKURA, Y
    SENDA, M
    MAGATA, Y
    IWASAKI, Y
    MATOBA, N
    TSUCHIDA, T
    TAMAKI, N
    FUKUYAMA, H
    SHIBASAKI, H
    KONISHI, J
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 703 - 710
  • [8] Cerebral blood flow and personality: A positron emission tomography study
    Johnson, DL
    Wiebe, JS
    Gold, SM
    Andreasen, NC
    Hichwa, RD
    Watkins, GL
    Ponto, LLB
    AMERICAN JOURNAL OF PSYCHIATRY, 1999, 156 (02): : 252 - 257
  • [9] CEREBRAL BLOOD-FLOW MEASUREMENT BY POSITRON EMISSION TOMOGRAPHY
    DUNCAN, CC
    BENNETT, GW
    MENT, LR
    ACTA NEUROCHIRURGICA, 1982, 64 (3-4) : 273 - 273
  • [10] Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography
    Henriksen, Otto M.
    Larsson, Henrik B. W.
    Hansen, Adam E.
    Gruner, Julie M.
    Law, Ian
    Rostrup, Egill
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (06) : 1290 - 1299