Simulation and measurement of grating-based X-ray phase-contrast imaging

被引:0
|
作者
Bartl, P. [1 ]
Bayer, F. [1 ]
Durst, J. [1 ]
Haas, W. [1 ,2 ]
Michel, T. [1 ]
Pelzer, G. [1 ]
Ritter, A. [1 ]
Weber, T. [1 ]
Anton, G. [1 ]
机构
[1] Univ Erlangen Nurnberg, ECAP, D-91058 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91058 Erlangen, Germany
关键词
Phase contrast; Grating-based interferometry; X-ray imaging; Photon-counting detector; Medipix; Simulation of X-rays; INTERFEROMETRY; TOMOGRAPHY; MEDIPIX2;
D O I
10.1016/j.nima.2010.11.061
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper we present results from simulations on grating-based phase contrast imaging. Herein, the performance of a grating-based interferometer concerning the X-ray's energy is shown. Additionally, geometric parameters of the interferometer were investigated. In the experimental part of this work we present the dependency of the Talbot-Lau interferometer setup on the lower energy threshold of the Medipix-detector. These are the first energy sensitive measurements; acquired within the applied method. Furthermore, we demonstrate the difference between a differential and an integral measurement by comparing the phase and absorption image. The conclusion of this work is the detailed characterisation of grating-based phase contrast imaging regarding its energy dependent behaviour and geometric parameters of the gratings. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S269 / S272
页数:4
相关论文
共 50 条
  • [1] Noise in x-ray grating-based phase-contrast imaging
    Weber, Thomas
    Bartl, Peter
    Bayer, Florian
    Durst, Juergen
    Haas, Wilhelm
    Michel, Thilo
    Ritter, Andre
    Anton, Gisela
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 4133 - 4140
  • [2] Contrast transfer function in grating-based x-ray phase-contrast imaging
    Huang, Jianheng
    Du, Yang
    Lin, Danying
    Liu, Xin
    Niu, Hanben
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 747 : 13 - 18
  • [3] Grating-based X-ray phase-contrast imaging at PETRA III
    Hipp, A.
    Beckmann, F.
    Lytaev, P.
    Greving, I.
    Lottermoser, L.
    Dose, T.
    Kirchhof, R.
    Burmester, H.
    Schreyer, A.
    Herzen, J.
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [4] Energy weighting in grating-based x-ray phase-contrast imaging
    Pelzer, Georg
    Weber, Thomas
    Anton, Gisela
    Sune, Rafael Ballabriga
    Bayer, Florian
    Campbell, Michael
    Haas, Wilhelm
    Horn, Florian
    Cudie, Xavi Llopart
    Michel, Norbert
    Mollenbauer, Uwe
    Rieger, Jens
    Ritter, Andre
    Ritter, Ina
    Woelfel, Stefan
    Wong, Winnie S.
    Zang, Andrea
    Michel, Thilo
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [5] Inverse geometry for grating-based x-ray phase-contrast imaging
    Donath, Tilman
    Chabior, Michael
    Pfeiffer, Franz
    Bunk, Oliver
    Reznikova, Elena
    Mohr, Juergen
    Hempel, Eckhard
    Popescu, Stefan
    Hoheisel, Martin
    Schuster, Manfred
    Baumann, Joachim
    David, Christian
    [J]. JOURNAL OF APPLIED PHYSICS, 2009, 106 (05)
  • [6] Analysis of partial coherence in grating-based phase-contrast X-ray imaging
    Wang, Zhili
    Liu, Xiaosong
    Zhu, Peiping
    Huang, Wanxia
    Yuan, Qingxi
    Li, Enrong
    Liu, Yijin
    Zhang, Kai
    Hong, Youli
    Wu, Ziyu
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 319 - 322
  • [7] Spectroscopic Measurements Concerning Grating-Based X-Ray Phase-Contrast Imaging
    Weber, Thomas
    Bartl, Peter
    Bayer, Florian
    Durst, Juergen
    Haas, Wilhelm
    Michel, Thilo
    Pelzer, Georg
    Ritter, Andre
    Anton, Gisela
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [8] Beam hardening effects in grating-based x-ray phase-contrast imaging
    Chabior, Michael
    Donath, Tilman
    David, Christian
    Bunk, Oliver
    Schuster, Manfred
    Schroer, Christian
    Pfeiffer, Franz
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1189 - 1195
  • [9] Fast Grating-based X-ray Phase-contrast Tomosynthesis
    Xi, Yan
    Zhao, Jun
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2320 - 2323
  • [10] A fast alignment method for grating-based X-ray phase-contrast imaging systems
    Schuster, M.
    Ludwig, V
    Akstaller, B.
    Seifert, M.
    Wolf, A.
    Michel, T.
    Neumayer, P.
    Funk, S.
    Anton, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14