Development of a diagnostic method for Parkinson's disease by reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection

被引:16
|
作者
Oh, Minhwa [1 ]
Huh, Eugene [2 ,3 ]
Oh, Myung Sook [3 ,4 ,5 ]
Jeong, Ji-Seon [6 ,7 ]
Hong, Seon-Pyo [1 ,4 ,5 ]
机构
[1] Kyung Hee Univ, Grad Sch, Dept Oriental Pharmaceut Sci, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[2] Kyung Hee Univ, Grad Sch, Dept Sci Korean Med, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[3] Kyung Hee Univ, Grad Sch, Dept Life & Nanopharmaceut Sci, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[4] Kyung Hee Univ, Dept Oriental Pharmaceut Sci, Coll Pharm, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[5] Kyung Hee Univ, Kyung Hee East West Pharmaceut Res Inst, 26 Kyungheeedae Ro, Seoul 02447, South Korea
[6] Korea Res Inst Stand & Sci, Dept Metrol Qual Life, Ctr Bioanal, 267 Gajeong Ro, Daejeon 34113, South Korea
[7] Univ Sci & Technol, Dept Bioanalyt Sci, 217 Gajeong Ro, Daejeon 34113, South Korea
关键词
Mice striatum; Parkinson's disease; Dopamine; 3,4-dihydroxyphenylacetic acid; Serotonin; 5-hydroxyindolacetic acid; Homovanillic acid; Integrated pulsed amperometric detection; Direct method; Biomarker; TANDEM MASS-SPECTROMETRY; ELECTROCHEMICAL DETECTION; BIOGENIC-AMINES; HUMAN PLASMA; DOPAMINE; HPLC; NOREPINEPHRINE; SEPARATION; LEVODOPA; 3-O-METHYLDOPA;
D O I
10.1016/j.jpba.2018.02.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed a diagnostic method for Parkinson's disease by simultaneously analyzing biogenic amines and their metabolites using reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection (RP-HPLC-IPAD) method. Dopamine (DA), 3, 4-dihydroxyphenylacetic acid (DOPAC), serotonin (5-HT), 5-hydroxyindolacetic acid (5-HIAA), and homovanillic acid (HVA) were used as biomarkers to diagnose Parkinson's disease. All target components were detected with good sensitivity using sodium hydroxide (as a post-column eluent). The limit of detection (S/N = 3) and limit of quantification (S/N = 10) of the target components ranged from 0.020 to 2.400 ng and from 0.080 to 8.000 ng, respectively. The coefficients of linear regression ranged from 0.9996 to 1.0000, all inter-day and intra-day precision values were <3.43%, and the average recovery and RSD ranged from 97.55 to 103.60% and 0.22 to 4.79% for mice striatum samples. This method exhibited good selectivity, sensitivity, and reproducibility and can be used directly without any pretreatment steps. Our method will be useful as a tool to diagnose Parkinson's disease. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条
  • [1] Simultaneous quantification of six nonpolar ginsenosides in white ginseng by reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection
    Song, Hyeyoung
    Song, Kyung-Won
    Hong, Seon-Pyo
    JOURNAL OF GINSENG RESEARCH, 2020, 44 (04) : 563 - 569
  • [2] Simultaneous quantification method for eleutheroside B, eleutheroside E, chiisanoside, and sesamin using reverse-phase high-performance liquid chromatography coupled with ultraviolet detection and integrated pulsed amperometric detection
    Kim, YeaIn
    Jung, Young-Ju
    Yoon, Hae-Jee
    Kwon, Ha-Jeong
    Hong, Seon-Pyo
    HELIYON, 2023, 9 (01)
  • [3] Quantification of isoflavonoids and triterpene saponins in Astragali Radix, the root of Astragalus membranaceus, via reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection
    Lee, Seung-Min
    Jeong, Ji-Seon
    Kwon, Ha-Jeong
    Hong, Seon-Pyo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1070 : 76 - 81
  • [4] AMPEROMETRIC DETECTION OF THYROID-HORMONES FOLLOWING REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HEPLER, BR
    WEBER, SG
    PURDY, WC
    ANALYTICA CHIMICA ACTA, 1980, 113 (02) : 269 - 276
  • [5] A reversed-phase high-performance liquid chromatography method with pulsed amperometric detection for the determination of glycosides
    Kwon, Ha-Jeong
    Jeong, Ji-Seon
    Lee, Yong-Moon
    Hong, Seon-Pyo
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1185 (02) : 251 - 257
  • [6] Development and Validation of Reverse-Phase High-Performance Liquid Chromatography Method for Simultaneous Estimation of Doxorubicin and Clotrimazole
    Sharma, Priyanka
    Kapoor, Bhupinder
    Hussain, Md Sadique
    Singh, Gurvinder
    Rani, Pooja
    Saini, Balraj
    Wadhwa, Pankaj
    Kumar, Rajesh
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2024, 22 (02) : 86 - 96
  • [7] ELECTROCHEMICAL DETECTION OF PHOSPHOLIPID HYDROPEROXIDES IN REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    YAMADA, K
    TERAO, J
    MATSUSHITA, S
    LIPIDS, 1987, 22 (02) : 125 - 128
  • [8] Urinary neopterin quantification by reverse-phase high-performance liquid ultraviolet chromatography with detection
    de Castro, MR
    Di Marco, GS
    Arita, DY
    Teixeira, LC
    Pereira, AB
    Casarini, DE
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 59 (03): : 275 - 283
  • [9] DESALTING OF NUCLEOTIDES BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NORTHROP, DB
    NEWTON, CJ
    ANALYTICAL BIOCHEMISTRY, 1980, 103 (02) : 359 - 361
  • [10] QUANTITATION OF AMPHOTERICINS BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MARGOSIS, M
    ASZALOS, A
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (06) : 835 - 838