First-in-Human Evaluation of the Safety and Efficacy of a Novel Stent Positioning Assistance System for Precise Positioning of Coronary Stents

被引:0
|
作者
Hellou, Elias [1 ,2 ]
Jonas, Michael [3 ]
Dvir, Danny [4 ]
机构
[1] EMMS Hosp, Cardiovasc Dept, Nazareth, Israel
[2] Technion Israeli Inst Technol, Haifa, Israel
[3] Hebrew Univ Jerusalem, Kaplan Med Ctr, HeartInst, Jerusalem, Israel
[4] Hebrew Univ Jerusalem, Jesselson Integrated Heart Ctr, ShaareZedek Med Ctr, Intervent Cardiol, Jerusalem, Israel
关键词
DEPLOYMENT; IMPACT; MISS;
D O I
10.1155/2022/1683309
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was planned for evaluating the safety and efficacy of SPAS (stent positioning assistance system) device in first-in-human procedures. Background. SPAS is a novel device that can be used for improved positioning of coronary stents. Methods. Consecutive patients underwent percutaneous coronary intervention (PCI) with the SPAS device. Device-related adverse and serious adverse events were evaluated in addition to a dedicated questionnaire completed by operators immediately after using SPAS. Results. The SPAS device was deployed in 55 PCI procedures, comprising of heavily calcified lesions (33.3%), totally occluded (7.4%), and severely tortuous vessels (7.4%). In these procedures, nonbifurcation and nonostial (53.7%), bifurcation (22.2%), and edge-to-edge (24.1%) stenting techniques were employed. Analysis of the pooled scores for the five satisfaction-related questions gave an average score of 5.6 +/- 1.5, with 40 (75.5%) operators providing an average satisfaction grade of >5; the average operator-rated SPAS device accuracy performance scores exceeded 6 out of 7 (on visual analog score). The time spent for positioning the stent with the SPAS device averaged 41 +/- 68.0 seconds. The SPAS device was rated as easy to use (6.1 +/- 1.6) and reliable (6.1 +/- 1.7). No device-related adverse events were reported. Conclusion. This stent positioning device was evaluated in a consecutive cohort of standard and complex PCI procedures. The device was shown to be safe, easy, and precise to use, both in standard and complex cases.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] First-in-Human Evaluation of a Novel Robotic-Assisted Coronary Angioplasty System
    Granada, Juan F.
    Delgado, Juan A.
    Uribe, Maria Paola
    Fernandez, Andres
    Blanco, Guillermo
    Leon, Martin B.
    Weisz, Giora
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (04) : 460 - 465
  • [2] First-in-human evaluation of a sirolimus-eluting coronary stent on an integrated delivery system: the DIRECT study
    Webster, Mark
    Harding, Scott
    McClean, Dougal
    Jaffe, Warwick
    Ormiston, John
    Aitken, Andrew
    Watson, Timothy
    [J]. EUROINTERVENTION, 2013, 9 (01) : 46 - 53
  • [3] ARISE: First-In-Human Evaluation of a Novel Stent Graft to Treat Ascending Aortic Dissection
    Roselli, Eric E.
    Atkins, Marvin D.
    Brinkman, William
    Coselli, Joseph
    Desai, Nimesh
    Estrera, Anthony
    Johnston, Douglas R.
    Patel, Himanshu
    Preventza, Ourania
    Vargo, Patrick R.
    Fleischman, Fernando
    Taylor, Bradley S.
    Reardon, Michael J.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2023, 30 (04) : 550 - 560
  • [4] Efficacy and Safety of Novel NovaCross Microcatheter for Chronic Total Occlusions: First-in-Human Study
    Walsh, Simon
    Dudek, Dariusz
    Bryniarski, Leszek
    Assali, Abid
    Danenberg, Haim
    Lotan, Chaim
    Hanratty, Colm
    Wilkolek, Piotr
    Kornowski, Ran
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (03): : 88 - 91
  • [5] First-in-Human Evaluation of a Sirolimus-Eluitng Fixed-Wire Coronary Stent Integrated Delivery System: the Direct Study
    Webster, Mark W.
    Ormiston, John A.
    McCLean, Dougal
    Jaffe, Warwick
    Harding, Scott
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B244 - B244
  • [6] A novel endovascular robotic-assisted system for endovascular aortic repair: first-in-human evaluation of practicability and safety
    Song, Chao
    Xia, Shibo
    Zhang, Lei
    Wang, Kundong
    Li, Haiyan
    Guo, Wenying
    Zhu, Longtu
    Lu, Qingsheng
    [J]. EUROPEAN RADIOLOGY, 2023, 33 (11) : 7408 - 7418
  • [7] Safety and Feasibility of a Novel, Second Generation Robotic-Assisted System for Percutaneous Coronary Intervention: First-in-Human Report
    Smitson, Christopher
    Ang, Lawrence
    Reeves, Ryan
    Patel, Mitul
    Mahmud, Ehtisham
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B55 - B56
  • [8] A novel endovascular robotic-assisted system for endovascular aortic repair: first-in-human evaluation of practicability and safety
    Chao Song
    Shibo Xia
    Lei Zhang
    Kundong Wang
    Haiyan Li
    Wenying Guo
    Longtu Zhu
    Qingsheng Lu
    [J]. European Radiology, 2023, 33 : 7408 - 7418
  • [9] First-in-Human Images of Coronary Atherosclerosis and Coronary Stents Using a Novel Hybrid Intravascular Ultrasound and Optical Coherence Tomographic Catheter
    Sheth, Tej N.
    Pinilla-Echeverri, Natalia
    Mehta, Shamir R.
    Courtney, Brian K.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (23) : 2427 - 2430
  • [10] Safety and Feasibility of a Novel, Second-Generation Robotic-Assisted System for Percutaneous Coronary Intervention: First-in-Human Report
    Smitson, Christopher C.
    Ang, Lawrence
    Pourdjabbar, Ali
    Reeves, Ryan
    Patel, Mitul
    Mahmud, Ehtisham
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2018, 30 (04): : 152 - 156