Intraoperative Cerebral Measurements Using Implantable Cortical Multimodality Probe

被引:0
|
作者
Ishihara, Yuya [1 ]
Sakai, Shun
Yamakawa, Toshitaka [1 ]
Inoue, Takao [2 ]
Suzuki, Michiyasu
Sakata, Tadashi [1 ]
Ueda, Yuichi [1 ]
机构
[1] Kumamoto Univ, Grad Sch Sci & Technol, Dept Comp Sci & Elect Engn, Kumamoto, Japan
[2] Yamaguchi Univ, Dept Neurosurg, Yamaguchi, Japan
关键词
NEAR-INFRARED SPECTROSCOPY; TEMPERATURE;
D O I
10.1109/embc.2019.8856488
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a multimodality probe that simultaneously measures electroencephalograms, cerebral hemodynamics, and brain surface temperature was developed. This probe has six channels, and each channel has a platinum electrode for cortical electroencephalogram measurements, light emitting diodes, and photodiodes for hemodynamic measurements using near-infrared spectroscopy (NIRS), and a thermistor for measuring the cerebral surface temperature (BrT). A probe with a width of 8.0 mm and maximum total thickness of 0.7 mm was fabricated using flexible printed circuit board technology for chronic intracranial placement. Brain activity using the prototype probe at the resected site was measured and its function performance was evaluated. Characteristic epileptogenic abnormal electroencephalograms accompanied by polarity reversal between channels occurred at 16 min and 38 s. It was concluded that the brain cells consumed oxygen during the occurrence of abnormal electroencephalograms. At this time, no noticeable change in HbT values could be confirmed.
引用
收藏
页码:4372 / 4375
页数:4
相关论文
共 50 条
  • [1] Evaluation of the Pressure Measurement Function of an Implantable Multimodality Probe
    Wakuya, Manami
    Yamakawa, Toshitaka
    Inoue, Takao
    Suzuki, Michiyasu
    2020 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC), 2020, : 972 - 975
  • [2] Implantable probe systems for cortical neuroprostheses
    Kipke, DR
    2004 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOLS 1-4, PROCEEDINGS, 2004, : 1747 - 1747
  • [3] Implantable neural probe systems for cortical neuroprostheses
    Kipke, DR
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 5344 - 5347
  • [4] Assessment of the relationship between standard probe and implantable fiber measurements of cortical bone blood flow: A canine study
    Jain, R
    Podworny, N
    Anderson, GI
    Schemitsch, EH
    CALCIFIED TISSUE INTERNATIONAL, 1996, 59 (01) : 64 - 69
  • [5] Intraoperative evaluation using a multimodality probe of temperature-dependent neurovascular modulation during focal brain cooling
    Inoue, Takao
    Nomura, Sadahiro
    Yamakawa, Toshitaka
    Takara, Sayuki
    Imoto, Hirochika
    Maruta, Yuichi
    Niwayama, Masatsugu
    Suzuki, Michiyasu
    CLINICAL NEUROPHYSIOLOGY, 2025, 173 : 31 - 42
  • [6] Fabrication of a Multilayer Implantable Cortical Microelectrode Probe to Improve Recording Potential
    Liu, Xin
    Bibineyshvili, Yelena
    Robles, Denise A.
    Boreland, Andrew J.
    Margolis, David J.
    Shreiber, David, I
    Zahn, Jeffrey D.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2021, 30 (04) : 569 - 581
  • [7] The Lifetime and Attenuation Properties Measurements of a US/MR Multimodality Molecular Probe
    Liao, Ai-Ho
    Shen, Che-Chou
    Cheng, Chih-Hao
    Chuang, Ho-Chiao
    Lin, Chin-Hsiang
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 6965 - 6968
  • [8] Intraoperative measurement of peritumoral regional cortical cerebral blood flow
    Sioutos, PJ
    Carter, LP
    Weinand, ME
    Hamilton, AJ
    Nees, J
    Orosco, J
    ONCOLOGY REPORTS, 1996, 3 (03) : 593 - 596
  • [9] DETECTION OF CEREBRAL-TUMORS WITH A POSITRON SENSITIVE INTRAOPERATIVE PROBE
    MAZZIOTTA, JC
    DAGHIGHIAN, F
    HOFFMAN, E
    IKEZAKI, K
    BLACK, K
    SIEGEL, S
    ANNALS OF NEUROLOGY, 1991, 30 (02) : 237 - 237
  • [10] INTRAOPERATIVE MEASUREMENT OF CORTICAL BLOOD-FLOW ADJACENT TO CEREBRAL AVM USING LASER DOPPLER VELOCIMETRY
    ROSENBLUM, BR
    BONNER, RF
    OLDFIELD, EH
    JOURNAL OF NEUROSURGERY, 1987, 66 (03) : 396 - 399