Role of coherent structures on Reynolds stresses in a 2-D bubble column

被引:102
|
作者
Mudde, RF
Lee, DJ
Reese, J
Fan, LS
机构
[1] OHIO STATE UNIV,DEPT CHEM ENGN,COLUMBUS,OH 43210
[2] DELFT UNIV TECHNOL,KRAMERS LAB FYS TECHNOL,DELFT,NETHERLANDS
关键词
D O I
10.1002/aic.690430407
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The hydrodynamics of two-dimensional bubble columns operated in various flow regimes are studied using particle image velocimetry. Both averaged velocity profiles and Reynolds stress profiles are obtained and discussed in relation to large-scale structures present in the flow. The normal stresses, dominated by large-scale structures, are an order of magnitude higher than the shear stress. It is found that the contribution from the bubbles to the shear to the normal stresses is negligible. A time series of the flow field is studied, demonstrating that the flow could be split into a low-frequency contribution due to the vortical structures and a high-frequency fluctuating part. The latter gives rise to flat normal stress profiles, and the former is responsible for the original form of the normal sh ess profiles. The shear stress in the smaller columns investigated can be related to the averaged vertical velocity profile according to a Boussinesq approximation. Data on the eddy viscosity are presented.
引用
收藏
页码:913 / 926
页数:14
相关论文
共 50 条
  • [1] Pressure effect on the flow fields and the Reynolds stresses in a bubble column
    Lee, DJ
    McLain, BR
    Cui, Z
    Fan, LS
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (05) : 1442 - 1447
  • [2] Coherent flow structures in bubble column reactors
    Joshi, JB
    Vitankar, VS
    Kulkarni, AA
    Dhotre, MT
    Ekambara, K
    [J]. CHEMICAL ENGINEERING SCIENCE, 2002, 57 (16) : 3157 - 3183
  • [3] Coherent structures and axial dispersion in bubble column reactors
    Groen, JS
    Oldeman, RGC
    Mudde, RF
    VandenAkker, HEA
    [J]. CHEMICAL ENGINEERING SCIENCE, 1996, 51 (10) : 2511 - 2520
  • [4] Dynamics of a bubble column: Influence of gas distribution on coherent structures
    Harteveld, WK
    Mudde, RF
    van den Akker, HEA
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 81 (3-4): : 389 - 394
  • [5] Prediction of dynamic heat transfer of a 2-D bubble column using ANNs
    Hasegawa, T
    Chen, W
    Kuramoto, K
    Kikuchi, R
    Tsutsumi, A
    Otawara, K
    [J]. KAGAKU KOGAKU RONBUNSHU, 2001, 27 (04) : 461 - 465
  • [6] Lagrangian coherent structures analysis of gas-liquid flow in a bubble column
    Wu Qin
    Wang GuoYu
    Huang Biao
    Bai ZeYu
    [J]. SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2014, 57 (06) : 1169 - 1177
  • [7] Lagrangian coherent structures analysis of gas-liquid flow in a bubble column
    Qin Wu
    GuoYu Wang
    Biao Huang
    ZeYu Bai
    [J]. Science China Physics, Mechanics & Astronomy, 2014, 57 : 1169 - 1177
  • [8] Lagrangian coherent structures analysis of gas-liquid flow in a bubble column
    WU Qin
    WANG GuoYu
    HUANG Biao
    Bai ZeYu
    [J]. Science China(Physics,Mechanics & Astronomy), 2014, Mechanics & Astronomy)2014 (06) : 1169 - 1177
  • [9] THE ROLE OF COHERENT STRUCTURES IN BUBBLE TRANSPORT BY TURBULENT SHEAR FLOWS
    SENE, KJ
    HUNT, JCR
    THOMAS, NH
    [J]. JOURNAL OF FLUID MECHANICS, 1994, 259 : 219 - 240
  • [10] Mixing in bubble column reactors: Role of unsteady flow structures
    Buwa, VV
    Ranade, VV
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 81 (3-4): : 402 - 411