A plasma separator with a multifunctional deformable chamber equipped with a porous membrane for point-of-care diagnostics

被引:2
|
作者
Qiu, Xianbo [1 ]
Jiang, Huiqin [1 ]
Zhang, Xiaolei [2 ]
Li, Ke [2 ]
Ge, Shengxiang [3 ]
Xia, Ningshao [3 ]
Mauk, Michael G. [4 ]
机构
[1] Beijing Univ Chem Technol, Inst Microfluid Chip Dev Biomed Engn, Coll Informat Sci & Technol, Beijing 100029, Peoples R China
[2] Beijing Wantai Biol Pharm Enterprise Co Ltd, Beijing 102206, Peoples R China
[3] Xiamen Univ, Natl Inst Diagnost & Vaccine Dev Infect Dis, Xiamen 361005, Peoples R China
[4] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
基金
中国国家自然科学基金;
关键词
BLOOD; CHIP; EXTRACTION;
D O I
10.1039/d0an01014f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditionally, plasma is extracted from whole blood using centrifuges in clinical laboratories, which is unsuitable for on-site testing. For point-of-care diagnostics, for example in HIV tests, to ensure the detection sensitivity for low-abundance analytical targets, a relatively large volume of plasma needs to be extracted from milliliters of blood with a simpler and easier-to-operate method than centrifugation. We report the development of a membrane-assisted, sedimentation-facilitated plasma separator with a multifunctional deformable chamber, which is able to perform plasma separation from undiluted whole blood in a short time. Multiple steps related to plasma separation, including cell sedimentation, cell filtration, and plasma driving and discharging, are all performed in or through the multifunctional deformable chamber equipped with a top-layer porous membrane, which significantly reduces the device complexity. Assisted by a simple jig or even hands, plasma separation can be conveniently performed upon mechanical actuation of the deformable chamber. Within 8 min, similar to 130 mu L of plasma can be conveniently extracted with the described device from 2.3 mL of whole blood. It has been demonstrated that HIV antibodies or virus spiked in whole blood can be successfully detected with reasonable sensitivity from the extracted plasma with the described pump-free device.
引用
收藏
页码:6138 / 6147
页数:10
相关论文
共 50 条
  • [1] Membrane-Based, Sedimentation-Assisted Plasma Separator for Point-of-Care Applications
    Liu, Changchun
    Mauk, Michael
    Gross, Robert
    Bushman, Frederic D.
    Edelstein, Paul H.
    Collman, Ronald G.
    Bau, Haim H.
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (21) : 10463 - 10470
  • [2] Mobile and Efficient Temperature and Humidity Control Chamber for Point-of-Care Diagnostics
    Hertneky, Brittany
    Eger, Josh
    Bailly, Mark
    Christen, Jennifer Blain
    [J]. 2019 IEEE HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2019, : 159 - 162
  • [3] Point-of-Care Endocrine Diagnostics
    Ehrenkranz, Joel
    [J]. ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2017, 46 (03) : 615 - +
  • [4] Getting to the point in point-of-care diagnostics for tuberculosis
    Ignatius, Elisa H.
    Cohen, Keira A.
    Bishai, William R.
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 2020, 130 (11): : 5671 - 5673
  • [5] Quo Vadis Point-of-Care Diagnostics? Report II of the SWISS SYMPOSIUM in Point-of-Care Diagnostics 2017
    Pfeifer, Marc E.
    [J]. CHIMIA, 2018, 72 (1-2) : 80 - 81
  • [6] Microfluidics Based Point-of-Care Diagnostics
    Pandey, Chandra M.
    Augustine, Shine
    Kumar, Saurabh
    Kumar, Suveen
    Nara, Sharda
    Srivastava, Saurabh
    Malhotra, Bansi D.
    [J]. BIOTECHNOLOGY JOURNAL, 2018, 13 (01)
  • [7] Point-of-Care Diagnostics in Equine Practice
    Slovis, Nathan M.
    Browne, Nimet
    Bozorgmanesh, Rana
    [J]. VETERINARY CLINICS OF NORTH AMERICA-EQUINE PRACTICE, 2020, 36 (01) : 161 - +
  • [8] Point-of-Care Coagulation Diagnostics in the Neurosurgery
    Adam, Elisabeth Hannah
    Fuellenbach, Christoph
    Lindau, Simone
    Konczalla, Juergen
    [J]. ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2018, 53 (06): : 425 - 439
  • [9] Point-of-Care Diagnostics for the Third World
    Stevenson, Robert L.
    [J]. AMERICAN LABORATORY, 2012, 44 (09) : 28 - 30
  • [10] Salt and Pepper for Point-of-Care Diagnostics
    Furin, Dominik
    Saemann, M.
    Proll, G.
    Schubert, M.
    Gauglitz, G.
    [J]. EUROSENSORS XXV, 2011, 25