Identifying the sources of the pulse artefact in EEG recordings made inside an MR scanner

被引:59
|
作者
Mullinger, Karen J. [1 ]
Havenhand, Jade [1 ]
Bowtell, Richard [1 ]
机构
[1] Univ Nottingham, Sir Peter Mansfield Magnet Resonance Ctr, Sch Phys & Astron, Nottingham NG7 2RD, England
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
Simultaneous EEG-fMRI; Pulse artefact; Artefact reduction; EVENT-RELATED POTENTIALS; STATIC MAGNETIC-FIELD; BALLISTOCARDIOGRAM ARTIFACT; SIMULTANEOUS EEG/FMRI; FMRI RECORDINGS; BRAIN ACTIVITY; REMOVAL; STRENGTH; MOTION;
D O I
10.1016/j.neuroimage.2012.12.070
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
EEG recordings made during concurrent fMRI are confounded by the pulse artefact (PA), which although smaller than the gradient artefact is often more problematic because of its variability over multiple cardiac cycles. A better understanding of the PA is needed in order to generate improved methods for reducing its effect in EEG-fMRI experiments. Here we performed a study aimed at identifying the relative contributions of three putative sources of the PA (cardiac-pulse-driven head rotation, the Hall effect due to pulsatile blood flow and pulse-driven expansion of the scalp) to its amplitude and variability. EEG recordings were made from 6 subjects lying in a 3 T scanner. Accelerometers were fixed on the forehead and temple to monitor head motion. A bite-bar and vacuum cushion were used to restrain the head, thus greatly attenuating the contribution of cardiac-driven head rotation to the PA, while an insulating layer placed between the head and the EEG electrodes was used to eliminate the Hall voltage contribution. Using the root mean square (RMS) amplitude of the PA averaged over leads and time as a measure of the PA amplitude, we found that head restraint and insulating layer reduced the PA by 61% and 42%, respectively, when compared with the PA induced with the subject relaxed, indicating that cardiac-pulse-driven head rotation is the dominant source of the PA. With both the insulating layer and head restraint in place, the PA was reduced in RMS amplitude by 78% compared with the relaxed condition, the remaining PA contribution resulting from scalp expansion or residual head motion. The variance of the PA across cardiac cycles was more strongly reduced by the insulating layer than the head restraint, indicating that the flow-induced Hall voltage makes a larger contribution than pulse-driven head rotation to the variability of the PA. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:75 / 83
页数:9
相关论文
共 6 条
  • [1] Physical Modeling of Pulse Artefact Sources in Simultaneous EEG/fMRI
    Yan, Winston X.
    Mullinger, Karen J.
    Geirsdottir, Gerda B.
    Bowtell, Richard
    [J]. HUMAN BRAIN MAPPING, 2010, 31 (04) : 604 - 620
  • [2] Removal of BCG artifacts from EEG recordings inside the MR scanner: A comparison of methodological and validation-related aspects
    Vanderperren, Katrien
    De Vos, Maarten
    Ramautar, Jennifer R.
    Novitskiy, Nikolay
    Mennes, Maarten
    Assecondi, Sara
    Vanrumste, Bart
    Stiers, Peter
    Van den Bergh, Bea R. H.
    Wagemans, Johan
    Lagae, Lieven
    Sunaert, Stefan
    Van Huffel, Sabine
    [J]. NEUROIMAGE, 2010, 50 (03) : 920 - 934
  • [3] BCG Artifact Removal for Reconstructing Full-scalp EEG inside the MR Scanner
    Xia, Hongjing
    Ruan, Dan
    Cohen, Mark S.
    [J]. 2013 3RD INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI 2013), 2013, : 178 - 181
  • [4] Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction
    Allen, PJ
    Polizzi, G
    Krakow, K
    Fish, DR
    Lemieux, L
    [J]. NEUROIMAGE, 1998, 8 (03) : 229 - 239
  • [5] Removing ballistocardiogram (BCG) artifact from full-scalp EEG acquired inside the MR scanner with Orthogonal Matching Pursuit (OMP)
    Xia, Hongjing
    Ruan, Dan
    Cohen, Mark S.
    [J]. FRONTIERS IN NEUROSCIENCE, 2014, 8
  • [6] Removal of Pulse Artefact from EEG Data Recorded in MR Environment at 3T. Setting of ICA Parameters for Marking Artefactual Components: Application to Resting-State Data
    Maggioni, Eleonora
    Arrubla, Jorge
    Warbrick, Tracy
    Dammers, Juergen
    Bianchi, Anna M.
    Reni, Gianluigi
    Tosetti, Michela
    Neuner, Irene
    Shah, N. Jon
    [J]. PLOS ONE, 2014, 9 (11):