Three-Dimensional Sonographic Measurement of Blood Volume Flow in the Umbilical Cord

被引:0
|
作者
Pinter, Stephen Z.
Rubin, Jonathan M.
Kripfgans, Oliver D. [1 ]
Treadwell, Marjorie C. [2 ]
Romero, Vivian C. [2 ]
Richards, Michael S.
Zhang, Man
Hall, Anne L. [3 ]
Fowlkes, J. Brian
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Obstet & Gynecol, Ann Arbor, MI 48109 USA
[3] GE Healthcare, Milwaukee, WI USA
基金
美国国家卫生研究院;
关键词
color flow; Doppler sonography; intrauterine growth restriction; umbilical; volume flow; HUMAN FETUS;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives Three-dimensional (3D) umbilical cord blood volume flow measurement with the intention of providing a straightforward, consistent, and accurate method that overcomes the limitations associated with traditional pulsed wave Doppler flow measurement and provides a means by which to recognize and manage at-risk pregnancies. Methods The first study involved 3D sonographic volume flow measurements in 7 healthy ewes whose pregnancies ranged from 18 to 19 weeks' gestation (7 singletons). Sonographic umbilical arterial and venous flow measurements from each fetus were compared to the corresponding average measured arterial/venous flow to assess the feasibility of measurement in a static vessel. A second complementary study involved 3D sonographic volume flow measurements in 7 healthy women whose pregnancies ranged from 17.9 to 36.3 weeks' gestation (6 singletons and I twin). Umbilical venous flow measurements were compared to similar flow measurements reported in the literature. Pregnancy outcomes were abstracted from the medical records of the recruited patients. Results In the fetal sheep model, arterial/venous flow comparisons yielded errors of 10% or less for 8 of the 9 measurements. In the clinical study, venous flow measurements showed agreement with the literature over a range of gestational ages. Two of the 7 patients in the clinical study had lower flow than anticipated for gestational age; one had a subsequent diagnosis of intrauterine growth restriction, and the other had preeclampsia. Conclusions Accurate measurement of umbilical blood volume flow can be performed with relative ease in both the sheep model and in humans using the proposed 3D sonographic flow measurement technique. Results encourage further development of the method as a means for diagnosis and identification of at-risk pregnancies.
引用
收藏
页码:1927 / 1934
页数:8
相关论文
共 50 条
  • [1] THREE-DIMENSIONAL SONOGRAPHIC VOLUME MEASUREMENT OF THE FETAL STOMACH
    Hata, Toshiyuki
    Tanaka, Hirokazu
    Noguchi, Junko
    Inubashiri, Eisuke
    Yanagihara, Toshihiro
    Kondoh, Shungo
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (11): : 1808 - 1812
  • [2] Three-dimensional sonographic volume measurement of the fetal cerebellum
    Hata, Toshiyuki
    Kuno, Atsushi
    Dai, Shu-Yan
    Inubashiri, Eisuke
    Hanaoka, Uiko
    Kanenishi, Kenji
    Yamashiro, Chizu
    Tanaka, Hirokazu
    Yanagihara, Toshihiro
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2007, 34 (01) : 17 - 21
  • [3] Three-dimensional sonographic volume measurement of the fetal spleen
    Hata, Toshiyuki
    Kuno, Atsushi
    Dai, Shu-Yan
    Inubashiri, Eisuke
    Hanaoka, Uiko
    Kanenishi, Kenji
    Yamashiro, Chizu
    Tanaka, Hirokazu
    Yanagihara, Toshihiro
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2007, 33 (05) : 600 - 605
  • [4] Three-dimensional sonographic volume measurement of the fetal lung
    Hata, Toshiyuki
    Kuno, Atsushi
    Dai, Shu-Yan
    Inubashiri, Eisuke
    Hanaoka, Uiko
    Kanenishi, Kenji
    Yamashiro, Chizu
    Tanaka, Hirokazu
    Yanagihara, Toshihiro
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2007, 33 (06) : 793 - 798
  • [5] Three-dimensional sonographic volume measurement of the fetal cerebellum
    Toshiyuki Hata
    Atsushi Kuno
    Shu-Yan Dai
    Eisuke Inubashiri
    Uiko Hanaoka
    Kenji Kanenishi
    Chizu Yamashiro
    Hirokazu Tanaka
    Toshihiro Yanagihara
    [J]. Journal of Medical Ultrasonics, 2007, 34 : 17 - 21
  • [6] Three-dimensional sonographic measurement of fetal renal volume
    Kuno A.
    Inubashiri E.
    Kanenishi K.
    Hata T.
    [J]. Journal of Medical Ultrasonics, 2006, 33 (1) : 43 - 47
  • [7] In vivo three-dimensional sonographic measurement of organ volume: Validation in the urinary bladder
    Riccabona, M
    Nelson, TR
    Pretorius, DH
    Davidson, TE
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1996, 15 (09) : 627 - 632
  • [8] In vivo three-dimensional sonographic measurement of organ volume: Validation in the urinary bladder
    Department of Radiology, University of California, San Diego, San Diego, CA, United States
    不详
    [J]. J. ULTRASOUND MED, 9 (627-632):
  • [9] Three-dimensional volume measurement
    Schwartz, G
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (01) : 4 - 5
  • [10] Three-dimensional sonographic measurement of liver volume in the small-for-gestational-age fetus
    Kuno, A
    Hayashi, Y
    Akiyama, M
    Yamashiro, C
    Tanaka, H
    Yanagihara, T
    Hata, T
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (04) : 361 - 366