Development of an isotope labeling ultra-high performance liquid chromatography mass spectrometric method for quantification of acylglycines in human urine

被引:29
|
作者
Stanislaus, Avalyn [1 ]
Guo, Kevin [1 ]
Li, Liang [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB, Canada
基金
加拿大创新基金会;
关键词
Tandem mass spectrometry; Liquid chromatography; Isotope labeling; Acylglycines; Endogenous metabolites; Metabolomics; INBORN-ERRORS; LC-MS/MS; VALIDATION; METABOLISM; DIAGNOSIS; DEFECTS; GLYCINE; RAT;
D O I
10.1016/j.aca.2012.05.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Acylglycines play a crucial regulatory and detoxification role in the accumulation of the corresponding acyl CoA esters and are an important class of metabolites in the diagnoses of inborn errors of metabolism. Sensitive quantification of a large number of acylglycines not only improves diagnosis but also enables the discovery of potential new biomarkers of diseases. We report an ultra-high performance liquid chromatography tandem mass spectrometry (UPLC-MS) method for quantifying acylglycines in human urine with high sensitivity. This method is based on the use of a newly developed isotope labeling reagent, p-dimethylaminophenacyl (DmPA) bromide, to label acylglycines to improve detection sensitivity. Eighteen acylglycines, namely acetylglycine, propionylglycine, isobutyrylglycine, butyrylglycine, 4-hydroxyphenylacetylglycine, 2-furoylglycine, tiglylglycine, 2-methybutyrylglycine, 3-methylcrotonylglycine, isovalerylglycine, valerylglycine, hexanoylglycine, phenylacetylglycine, phenylpropionylglycine, glutarylglycine. heptanoylglycine, octanoylglycine and suberylglycine, were measured. This method uses calibration standards prepared in surrogate matrix (un-derivatized urine) and stable-isotope labeled analytes as the internal standards. The analysis was carried out in the positive ion detection mode using multiple reaction monitoring (MRM) survey scans. The calibration curves were validated over the range of 1.0-500 nM. The method achieved a lower limit of quantitation (LLOQ) of 1-5 nM for all analytes, as measured by the standard derivations associated with calibration curves and confirmed in surrogate matrix; the signal-to-noise ratio at LLOQ ranged from 12.50 to 156.70. Both accuracy (% RE or relative error) and precision (% CV) were <15%. Matrix effects were minimized using the surrogate matrix. All eighteen analytes were stable in urine for at least 5 h at room temperature, autosampler (4 degrees C) for 24 h. 7 weeks at -20 degrees C and after three freeze/thaw cycles. This surrogate matrix approach was validated using a standard addition experiment. As an example of applications, the endogenous concentrations of all eighteen analytes in urine samples of 20 healthy individuals collected in three consecutive days (i.e., 60 samples) were determined; there was no significant correlation found between the acylglycine profile and gender or body mass indices. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 172
页数:12
相关论文
共 50 条
  • [1] Development of an Ultra-High Performance Liquid Chromatography method for the simultaneous mass detection of tobacco biomarkers in urine
    Colsoul, Marie-Lise
    Goderniaux, Nicolas
    Vanpee, Dominique
    Galanti, Laurence
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1210
  • [2] Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine
    Fraselle, S.
    De Cremer, K.
    Coucke, W.
    Glorieux, G.
    Vanmassenhove, J.
    Schepers, E.
    Neirynck, N.
    Van Overmeire, I.
    Van Loco, J.
    Van Biesen, W.
    Vanholder, R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 988 : 88 - 97
  • [3] Development and validation of a ultra high performance liquid chromatography-tandem mass spectrometric method for the direct detection of formoterol in human urine
    Sardela, V. F.
    Deventer, K.
    Pereira, H. M. G.
    de Aquino Neto, F. R.
    Van Eenoo, P.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 471 - 475
  • [4] Quantification of Influenza Neuraminidase Activity by Ultra-High Performance Liquid Chromatography and Isotope Dilution Mass Spectrometry
    Solano, Maria I.
    Woolfitt, Adrian R.
    Willianis, Tracie L.
    Pierce, Carrie L.
    Gubareva, Larisa V.
    Mishin, Vasiliy
    Barr, John R.
    ANALYTICAL CHEMISTRY, 2017, 89 (05) : 3130 - 3137
  • [5] Development and validation of an ultra-high performance liquid chromatography - high resolution mass spectrometry method for the quantification of total and free teicoplanin in human plasma
    Deltombe, Olivier
    Mertens, Tom
    Eloot, Sunny
    Verstraete, Alain G.
    CLINICAL BIOCHEMISTRY, 2019, 65 : 29 - 37
  • [6] A simple and reliable ultra-high performance liquid chromatography coupled with tandem mass spectrometry method for simultaneous quantification of tyrosine and its metabolites in human urine
    Liu, Fan
    Li, Bin
    Yang, Yongli
    Wan, Yiqun
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2018, 41 (17-18) : 1013 - 1019
  • [7] Development, validation, and application of an ultra-high performance liquid chromatography-tandem mass spectrometry method for the estimation of Ropanicant in human plasma and urine
    Nirogi, Ramakrishna
    Kalaikadhiban, Ilayaraja
    Rayapati, Lakshmi Prasanna
    Pantangi, Hanumanth Rao
    Chunduru, Prathyusha
    Jetta, Satish
    Jubre, Avinash
    Mohammed, Abdul Rasheed
    JOURNAL OF CHROMATOGRAPHY OPEN, 2023, 3
  • [8] Development and validation of an ultra-high performance liquid chromatography with tandem mass spectrometry method for the simultaneous quantification of direct oral anticoagulants in human plasma
    Zhang, Yu-Fei
    Liu, Xiao-Qin
    Wang, Yang
    Xu, Xin
    Zhong, Ming-Kang
    Zhang, Pu
    Ma, Chun-Lai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1182
  • [9] Development and validation of an ultra-high performance liquid chromatography tandem mass spectrometry method for quantifying thyreostats in urine without derivatisation
    Bussche, J. Vanden
    Vanhaecke, L.
    Deceuninck, Y.
    Verheyden, K.
    Wille, K.
    Bekaert, K.
    Le Bizec, B.
    De Brabander, H. F.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) : 4285 - 4293
  • [10] Quantification of clenbuterol at trace level in human urine by ultra-high pressure liquid chromatography-tandem mass spectrometry
    Nicoli, Raul
    Petrou, Michael
    Badoud, Flavia
    Dvorak, Jiri
    Saugy, Martial
    Baume, Norbert
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1292 : 142 - 150