Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

被引:311
|
作者
Mentiplay, Benjamin F. [1 ]
Perraton, Luke G. [1 ]
Bower, Kelly J. [1 ]
Adair, Brooke [2 ]
Pua, Yong-Hao [3 ]
Williams, Gavin P. [4 ,5 ]
McGaw, Rebekah [1 ]
Clark, Ross A. [1 ]
机构
[1] Australian Catholic Univ, Fac Hlth Sci, Sch Exercise Sci, Melbourne, Vic, Australia
[2] Australian Catholic Univ, Fac Hlth Sci, Sch Allied Hlth, Melbourne, Vic, Australia
[3] Singapore Gen Hosp, Dept Physiotherapy, Singapore, Singapore
[4] Epworth Healthcare, Dept Physiotherapy, Melbourne, Vic, Australia
[5] Univ Melbourne, Fac Med Denistry & Hlth Sci, Sch Physiotherapy, Melbourne, Vic, Australia
来源
PLOS ONE | 2015年 / 10卷 / 10期
关键词
TEST-RETEST RELIABILITY; FORCE DEVELOPMENT; FUNCTIONAL PERFORMANCE; CEREBRAL-PALSY; NEUROMUSCULAR PERFORMANCE; HIP OSTEOARTHRITIS; STROKE; KNEE; ADULTS; ASSOCIATION;
D O I
10.1371/journal.pone.0140822
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23 +/- 5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients >= 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs >= 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31-0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Reliability and validity of hand-held dynamometry for assessing lower limb muscle strength
    Lipovsek, Tjasa
    Kacin, Alan
    Puh, Urska
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2022, 30 (03) : 231 - 240
  • [2] RELIABILITY OF HAND-HELD DYNAMOMETRY IN MEASURING MUSCLE STRENGTH
    BURDETT, RG
    WHITNEY, SL
    [J]. PHYSICAL THERAPY, 1987, 67 (05): : 748 - 748
  • [3] Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study
    Hebert, Luc J.
    Maltais, Desiree B.
    Lepage, Celine
    Saulnier, Joanne
    Crete, Melanie
    Perron, Marc
    [J]. PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) : 289 - 299
  • [4] Commentary on "Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study"
    Nervik, Deborah
    Nicols, Jennifer Parent
    [J]. PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) : 300 - 300
  • [5] Psychometric properties of muscle strength assessment by hand-held dynamometry in healthy adults: A reliability study
    Morin, M.
    Hebert, L. J.
    Perron, M.
    Petitclerc, E.
    Lake, S.
    Duchesne, E.
    [J]. NEUROMUSCULAR DISORDERS, 2022, 32 : S72 - S72
  • [6] The reliability of hand-held dynamometry for strength assessment during electrically induced muscle contractions
    Kodesh, Einat
    Laufer, Yocheved
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (01) : 61 - 66
  • [7] Validity and Reliability of Hand-Held Dynamometry for Abdominal Flexion Muscular Assessment
    Tarca, Brett D.
    Wycherley, Thomas P.
    Meade, Anthony
    Bennett, Paul
    Ferrar, Katia E.
    [J]. JOURNAL OF SPORT REHABILITATION, 2021, 30 (02) : 343 - 346
  • [8] Hand-held dynamometry: factors influencing reliability and validity
    Bohannon, RW
    [J]. CLINICAL REHABILITATION, 1997, 11 (03) : 263 - 264
  • [9] Use of hand-held dynamometry in the evaluation of lower limb muscle strength in people with Huntington’s disease
    M. E. Busse
    G. Hughes
    C. M. Wiles
    A. E. Rosser
    [J]. Journal of Neurology, 2008, 255 : 1534 - 1540
  • [10] Use of hand-held dynamometry in the evaluation of lower limb muscle strength in people with Huntington's disease
    Busse, Monica E.
    Hughes, Gareth
    Wiles, Charles M.
    Rosser, Anne E.
    [J]. JOURNAL OF NEUROLOGY, 2008, 255 (10) : 1534 - 1540