Ultrafine and respirable particle exposure during vehicle fire suppression

被引:13
|
作者
Evans, Douglas E. [1 ]
Fent, Kenneth W. [2 ]
机构
[1] NIOSH, Chem Exposure & Monitoring Branch, Div Appl Res & Technol, Ctr Dis Control & Prevent, Cincinnati, OH 45226 USA
[2] NIOSH, Hazard Evaluat & Tech Assistance Branch, Div Surveillance Hazard Evaluat & Field Studies, Ctr Dis Control & Prevent, Cincinnati, OH 45226 USA
关键词
SHORT-TERM EXPOSURE; PARTICULATE MATTER; CARBON-MONOXIDE; HEART-DISEASE; PSYCHOLOGICAL RESPONSES; CANCER INCIDENCE; AIR-POLLUTION; FIREFIGHTERS; MORTALITY; EVENTS;
D O I
10.1039/c5em00233h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters' potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator's shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 x 10(7) particles per cm(3), 170 mg m(-3) respirable particle mass, 4700 mm(2) cm(-3) active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute timeweighted averages, engine compartment fires averaged 5.4 x 10(4) particles per cm(3), 0.36 mg m(-3) respirable particle mass, 92 mm(2) cm(-3) active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 x 10(5) particles per cm(3), 2.7 mg m(-3) respirable particle mass, 320 mm(2) cm(-3) active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews' potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures.
引用
收藏
页码:1749 / 1759
页数:11
相关论文
共 50 条
  • [1] Ultrafine Particle Exposure During Fire Suppression-Is It an Important Contributory Factor for Coronary Heart Disease in Firefighters?
    Baxter, C. Stuart
    Ross, Clara Sue
    Fabian, Thomas
    Borgerson, Jacob L.
    Shawon, Jamila
    Gandhi, Pravinray D.
    Dalton, James M.
    Lockey, James E.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2010, 52 (08) : 791 - 796
  • [2] Ultrafine Particle Exposure During Transit
    Knibbs, Luke
    Morawska, Lidia
    [J]. EPIDEMIOLOGY, 2011, 22 (01) : S188 - S189
  • [3] Characterization of Inhalable, Thoracic, and Respirable Fractions and Ultrafine Particle Exposure During Grinding, Brazing, and Welding Activities in a Mechanical Engineering Factory
    Iavicoli, Ivo
    Leso, Veruscka
    Fontana, Luca
    Cottica, Danilo
    Bergamaschi, Antonio
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2013, 55 (04) : 430 - 445
  • [4] Exposure to Inhalable, Respirable, and Ultrafine Particles in Welding Fume
    Lehnert, Martin
    Pesch, Beate
    Lotz, Anne
    Pelzer, Johannes
    Kendzia, Benjamin
    Gawrych, Katarzyna
    Heinze, Evelyn
    Van Gelder, Rainer
    Punkenburg, Ewald
    Weiss, Tobias
    Mattenklott, Markus
    Hahn, Jens-Uwe
    Moehlmann, Carsten
    Berges, Markus
    Hartwig, Andrea
    Bruening, Thomas
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (05): : 557 - 567
  • [5] Fine and ultrafine particle exposure during commuting by subway in Vienna
    Klaus-Peter Posselt
    Manfred Neuberger
    David Köhler
    [J]. Wiener klinische Wochenschrift, 2019, 131 : 374 - 380
  • [6] Fine and ultrafine particle exposure during commuting by subway in Vienna
    Posselt, Klaus-Peter
    Neuberger, Manfred
    Koehler, David
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 (15-16) : 374 - 380
  • [7] Epidemiological evidence of the effects of ultrafine particle exposure
    Wichmann, HE
    Peters, A
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2000, 358 (1775): : 2751 - 2768
  • [8] Research on Vehicle Exterior Fire Suppression Techniques
    Deng, Gaoshou
    Lin, Runing
    Shi, Xiaoxiang
    Zhang, Wen
    Chen, Hui
    [J]. INTERNATIONAL CONFERENCE ON ENERGY, POWER AND MECHANICAL ENGINEERING (EPME2019), 2020, 793
  • [9] Ultrafine particle penetration through idealized vehicle cracks
    Xu, Bin
    Liu, Shusen
    Zhu, Yifang
    [J]. JOURNAL OF AEROSOL SCIENCE, 2010, 41 (09) : 859 - 868
  • [10] Impact of smoking on in-vehicle fine particle exposure during driving
    Sohn, Hongji
    Lee, Kiyoung
    [J]. ATMOSPHERIC ENVIRONMENT, 2010, 44 (28) : 3465 - 3468