Modeling of Bulk Current Injection Setup for Automotive Immunity Test Using Electromagnetic Analysis

被引:8
|
作者
Kondo, Yosuke [1 ,2 ]
Izumichi, Masato [1 ]
Shimakura, Kei [1 ]
Wada, Osami [2 ]
机构
[1] DENSO CORP, Kariya, Aichi 4488661, Japan
[2] Kyoto Univ, Grad Sch Engn, Kyoto 6158510, Japan
关键词
conducted susceptibility; bulk current injection; S-parameter; electromagnetic analysis;
D O I
10.1587/transcom.E98.B.1212
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper provides a method based on electromagnetic (EM) analysis to predict conducted currents in the bulk current injection (BCI) test system for automotive components. The BCI test system is comprised of an injection probe, equipment under test (EUT), line impedance stabilization networks (LISNs), wires and an electric load. All components are modeled in full-wave EM analysis. The EM model of the injection probe enables us to handle multi wires. By using the transmission line theory, the BCI setup model is divided into several parts in order to reduce the calculation time. The proposed method is applied to an actual BCI setup of an automotive component and the simulated common mode currents at the input terminals of EUT have a good accuracy in the frequency range of 1-400 MHz. The model separation reduces the calculation time to only several hours.
引用
收藏
页码:1212 / 1219
页数:8
相关论文
共 50 条
  • [1] Electromagnetic Simulation of a Bulk Current Injection Test Setup for Automotive Applications
    Grassi, F.
    Pignari, S. A.
    [J]. PIERS 2011 SUZHOU: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2011, : 1406 - 1409
  • [2] Simulation of Bulk Current Injection Test for Automotive Components Using Electromagnetic Analysis
    Kondo, Yosuke
    Izumichi, Masato
    Wada, Osami
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2018, 60 (04) : 866 - 874
  • [3] Simulation of Bulk Current Injection Test Using Integrated Circuit Immunity Macro Model and Electromagnetic Analysis
    Kondo, Yosuke
    Ueyama, Shinichiro
    Izumichi, Masato
    Wada, Osami
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2016, : 118 - 122
  • [4] Double Bulk Current Injection: A new harness setup to correlate immunity test methods
    Cuvelier, M
    Rioult, J
    Klingler, M
    Ficheux, S
    [J]. 2003 IEEE International Symposium on Electromagnetic Compatibility (EMC), Vols 1 and 2, Symposium Record, 2003, : 225 - 228
  • [5] Circuit Modeling of the Test Setup for Pulsed Current Injection
    Cui, Zhitong
    Grassi, Flavia
    Pignari, Sergio A.
    [J]. 2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 726 - 728
  • [6] Circuit and Electromagnetic Modeling of Bulk Current Injection Test Setups Involving Complex Wiring Harnesses
    Toscani, Nicola
    Grassi, Flavia
    Spadacini, Giordano
    Pignari, Sergio A.
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2018, 60 (06) : 1752 - 1760
  • [7] The Research of Bulk Current Injection Probe Used for ICs Electromagnetic Immunity Measurement
    Zhang, Yaoxing
    Yan, Zhaowen
    Wang, Jianwei
    Liu, Wei
    Ning, Zhaoming
    Min, Zheng
    [J]. 2019 12TH INTERNATIONAL WORKSHOP ON THE ELECTROMAGNETIC COMPATIBILITY OF INTEGRATED CIRCUITS (EMC COMPO 2019), 2019, : 135 - 137
  • [8] Electromagnetic Susceptibility Analysis of I/O Buffers Using the Bulk Current Injection Method
    Kwak, SangKeun
    Nah, Wansoo
    Kim, SoYoung
    [J]. JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2013, 13 (02) : 114 - 126
  • [9] Comparison of Bulk Current Injection test methods of Automotive, Military and Civilian EMC standards
    Mahesh, G.
    Subbarao, B.
    [J]. INCEMIC 2008: 10TH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY, PROCEEDINGS, 2008, : 547 - 551
  • [10] "Virtual" Signal Integrity Test on Shielded/Unshielded Twisted-Wire Pairs Using the Bulk Current Injection Setup
    Rasm, Sahand
    Andrieu, Guillaume
    Reineix, Alain
    Tumayan, Remi
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (05) : 1357 - 1365