REDUCTION OF MOISTURE IN BASEMENTS OF BUILDINGS

被引:0
|
作者
Prejza, Martin [1 ]
Kic, Pavel [1 ]
机构
[1] Czech Univ Life Sci Prague, Prague, Suchdol Praha S, Czech Republic
关键词
insulation; humidity; reconstruction; temperature;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The paper is focused on the problems of increased humidity in the structure of buildings, both modern new buildings, but especially in old buildings, which have usually very poor insulation against ground moisture, or there have been changes in the subsoil. These problems are described in details and according to the situation of the building quality and its use the possible reconstruction is recommended. By the reconstruction the comfort inside buildings should be increased and thus satisfactory hygienic requirements achieved for health of people or possible use for other purposes. This will prevent also possible degradations of the walls and static problems of the building. All renovation methods are compared in terms of the costs of their implementation. As an example of practical realization an underground room in an old building in Prague was chosen. The measurements showed a totally unsatisfactory situation in this room, so the reconstruction was designed to improve the current situation. The comparison before and after reconstruction provides practical experience of the positive and negative aspects of the proposed and verified solution. The obtained results from this measurement and findings may be useful for further research in this issue as well as for practical solutions for similar problems in many older buildings.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 50 条
  • [1] INFLUENCE OF MOISTURE ON THERMAL PROPERTIES OF WALLS IN BASEMENTS OF BUILDINGS
    Kic, Pavel
    16TH INTERNATIONAL SCIENTIFIC CONFERENCE: ENGINEERING FOR RURAL DEVELOPMENT, 2017, : 492 - 495
  • [2] SIMPLIFIED DYNAMIC ANALYSIS OF BUILDINGS WITH BASEMENTS
    BALENDRA, T
    TAN, YP
    LEE, SL
    JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1982, 108 (05): : 895 - 914
  • [3] Moisture control strategies of habitable basements in cold climates
    Asphaug, Silje Kathrin
    Kvande, Tore
    Time, Berit
    Peuhkuri, Ruut H.
    Kalamees, Targo
    Johansson, Par
    Berardi, Umberto
    Lohne, Jardar
    BUILDING AND ENVIRONMENT, 2020, 169
  • [4] The moisture condition of the brick walls in the basements of a medieval monastery
    Hola, Anna
    3RD SCIENTIFIC CONFERENCE ENVIRONMENTAL CHALLENGES IN CIVIL ENGINEERING (ECCE 2018), 2018, 174
  • [5] Belt trusses and basements as "virtual" outriggers for tall buildings
    Nair, RS
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 1998, 35 (04): : 140 - 146
  • [6] Determination of design resistances of foundation beds of buildings with basements
    Pilyagin A.V.
    Mikheev V.V.
    Soil Mechanics and Foundation Engineering, 2002, 39 (2) : 50 - 54
  • [7] Belt Trusses and Basements as Virtual Outriggers for Tall Buildings
    Teng and Associates, Inc., Chicago, IL, United States
    Eng J, 4 (140-146):
  • [8] Retrofitting waterproof basements ("White Tanks") into existing buildings
    Kampen, Rolf
    BETON- UND STAHLBETONBAU, 2014, 109 : 96 - 105
  • [9] PLASTIC SOIL COVERS REDUCE MOISTURE IN HOMES WITHOUT BASEMENTS
    AMBURGEY, TL
    FRENCH, DW
    PEST CONTROL, 1970, 38 (11) : 26 - &
  • [10] Floor construction in basements during reconstruction of buildings in peaty territories
    Nikitin, A., V
    Nevzorov, A. L.
    Saenko, Yu, V
    GEOTECHNICS FUNDAMENTALS AND APPLICATIONS IN CONSTRUCTION: NEW MATERIALS, STRUCTURES, TECHNOLOGIES AND CALCULATIONS, 2019, 2 : 202 - 204