Standardization of multiple spirometers at widely separated times and places

被引:23
|
作者
Linn, WS [1 ]
Solomon, JC [1 ]
Gong, H [1 ]
Avol, EL [1 ]
Navidi, WC [1 ]
Peters, JM [1 ]
机构
[1] UNIV SO CALIF, SCH MED, LOS ANGELES, CA USA
关键词
D O I
10.1164/ajrccm.153.4.8616559
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We designed a system for a multiyear longitudinal study of lung function in 12 widely separated communities, intending to minimize variation in instrument-related data. We used multiple rolling-seal spirometer/personal computer systems. Calibrations were checked before, during, and after each day's field testing, using multiple calibration syringes with electronic readouts. The syringes were rotated to obtain data for each syringe-spirometer combination. Before and after each annual field testing season, a laboratory reference spirometer system was calibrated against a water-displacement device and an electronic frequency counter, and then compared against each field spirometer and syringe. Field equipment consistently met American Thoracic Society (ATS) specifications. Variance among spirometers exceeded variance among syringes. A spirometer occasionally changed its volume readout by approximate to 1 to 2%. More rarely, a syringe changed its delivered volume by approximate to 1%. Syringes' electronic readouts tracked changes in delivered volume. Syringe readouts were the most stable component of the system, and were more reproducible than the laboratory water-displacement calibration. We conclude that variation in spirometers may limit the reliability of epidemiologic findings, even when these spirometers meet ATS specifications. Frequent calibration checks traceable to an independent standard, and adjustment of individual test results, can reduce measurement error.
引用
收藏
页码:1309 / 1313
页数:5
相关论文
共 50 条
  • [1] Temperature standardization of multiple spirometers
    Linn, WS
    Solomon, JC
    Gong, H
    Avol, EL
    Peters, JM
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1998, 40 (02) : 148 - 152
  • [2] On the Spirometry and Spirometers Standardization
    Lopata, V.
    Sinekop, Yu.
    ElShabbah, M.
    Myasnyi, I.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 316 - 318
  • [3] STANDARDIZATION OF DIFFERENT SPIROMETERS
    ALI, BA
    ABRO, YM
    JAVED, NH
    ISLAM, MS
    RESPIRATION, 1988, 53 (01) : 58 - 63
  • [4] OBSERVATIONS OF SUDDEN IONOSPHERIC FREQUENCY DEVIATIONS AT WIDELY SEPARATED PLACES
    BAKER, DM
    DAVIES, K
    GRIMES, L
    NATURE, 1966, 210 (5033) : 253 - &
  • [5] 2 ADPCM ALGORITHMS WITH WIDELY SEPARATED ERROR RECOVERY TIMES
    APRILLE, TJ
    KUO, YL
    IEEE TRANSACTIONS ON COMMUNICATIONS, 1979, 27 (06) : 876 - 883
  • [6] Continuously tracking objects across multiple widely separated cameras
    Cai, Yinghao
    Chen, Wei
    Huang, Kaiqi
    Tan, Tieniu
    COMPUTER VISION - ACCV 2007, PT I, PROCEEDINGS, 2007, 4843 : 843 - 852
  • [7] Distributed Target Tracking in Multiple Widely Separated Radar Architectures
    Godrich, Hana
    Tajer, Ali
    Poor, H. Vincent
    2012 IEEE 7TH SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP (SAM), 2012, : 153 - 156
  • [8] ADAPTIVE TRACKING OF MULTIPLE SINUSOIDS WHOSE POWER LEVELS ARE WIDELY SEPARATED
    HODGKISS, WS
    PRESLEY, JA
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1981, 28 (06): : 550 - 561
  • [9] ADAPTIVE TRACKING OF MULTIPLE SINUSOIDS WHOSE POWER LEVELS ARE WIDELY SEPARATED
    HODGKISS, WS
    PRESLEY, JA
    IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1981, 29 (03): : 710 - 721
  • [10] 'TIMES AND PLACES'
    PINSKY, R
    PARNASSUS-POETRY IN REVIEW, 1977, 5 (02): : 51 - 54