Optimized parallel transmit and receive radiofrequency coil for ultrahigh-field MRI of monkeys

被引:36
|
作者
Gilbert, Kyle M. [1 ]
Gati, Joseph S. [1 ]
Barker, Kevin [1 ,2 ]
Everling, Stefan [1 ,3 ]
Menon, Ravi S. [1 ,4 ]
机构
[1] Univ Western Ontario, Ctr Funct & Metab Mapping, London, ON N6A 5B7, Canada
[2] Neuronitek, London, ON, Canada
[3] Univ Western Ontario, Dept Physiol & Pharmacol, London, ON N6A 5B7, Canada
[4] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5B7, Canada
基金
加拿大创新基金会; 加拿大健康研究院;
关键词
Transmit coil; Receive coil; Monkey; Parallel transmit; Echo-planar imaging; HIGH-RESOLUTION FMRI; CORTICAL LAMINATION; MACAQUE MONKEY; AWAKE MONKEY; STEADY-STATE; ARRAY COIL; IN-VIVO; RF COIL; RESONANCE; PATTERNS;
D O I
10.1016/j.neuroimage.2015.10.048
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Monkeys are a valuable model for investigating the structure and function of the brain. To attain the requisite resolution to resolve fine anatomical detail and map localized brain activation requires radiofrequency (RF) coils that produce high signal-to-noise ratios (SNRs) both spatially (image SNR) and temporally. Increasing the strength of the static magnetic field is an effective method to improve SNR, yet this comes with commensurate challenges in RF coil design. First, at ultrahigh field strengths, the magnetic field produced by a surface coil in a dielectric medium is asymmetric. In neuroimaging of rhesus macaques, this complex field pattern is compounded by the heterogeneous structure of the head. The confluence of these effects results in a non-uniform flip angle, but more markedly, a suboptimal circularly polarized mode with reduced transmit efficiency. Secondly, susceptibility-induced geometric distortions are exacerbated when performing echo-planar imaging (EPI), which is a standard technique in functional studies. This requires receive coils capable of parallel imaging with low noise amplification during image reconstruction. To address these challenges at 7 T, this study presents a parallel (8-channel) transmit coil developed for monkey imaging, along with a highly parallel (24-channel) receive coil. RF shimming with the parallel-transmit coil produced significant advantages-the transmit field was 38% more uniform than a traditional circularly polarized mode and 54% more power-efficient, demonstrating that parallel-transmit coils should be used for monkey imaging at ultrahigh field strengths. The receive coil had the ability to accelerate along an arbitrary axis with at least a three-fold reduction factor, thereby reducing geometric distortions in whole-brain EPI. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:153 / 161
页数:9
相关论文
共 50 条
  • [1] Multiple Parallel Round Leg Design for Quadrature Birdcage Coil in Ultrahigh-Field MRI
    Yongfeng Xu
    Qingqing Wen
    Hongyi Yang
    Kai Zhong
    [J]. Applied Magnetic Resonance, 2018, 49 : 209 - 216
  • [2] Multiple Parallel Round Leg Design for Quadrature Birdcage Coil in Ultrahigh-Field MRI
    Xu, Yongfeng
    Wen, Qingqing
    Yang, Hongyi
    Zhong, Kai
    [J]. APPLIED MAGNETIC RESONANCE, 2018, 49 (02) : 209 - 216
  • [3] Integration of an RF coil and commercial field camera for ultrahigh-field MRI
    Gilbert, Kyle M.
    Dubovan, Paul, I
    Gati, Joseph S.
    Menon, Ravi S.
    Baron, Corey A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2551 - 2565
  • [4] Parallel transmission for ultrahigh-field imaging
    Padormo, Francesco
    Beqiri, Arian
    Hajnal, Joseph V.
    Malik, Shaihan J.
    [J]. NMR IN BIOMEDICINE, 2016, 29 (09) : 1145 - 1161
  • [5] Transmit/Receive Radiofrequency Coil With Individually Shielded Elements
    Gilbert, Kyle M.
    Curtis, Andrew T.
    Gati, Joseph S.
    Klassen, L. Martyn
    Villemaire, Lauren E.
    Menon, Ravi S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1640 - 1651
  • [6] Electric field measurements and computational modeling at ultrahigh-field MRI
    Kangarlu, Alayar
    Tang, Lin
    Ibrahim, Tamer S.
    [J]. MAGNETIC RESONANCE IMAGING, 2007, 25 (08) : 1222 - 1226
  • [7] Ultrahigh-Field MRI whole-slice and localized RF field excitations using the same RF transmit array
    Ibrahim, Tamer S.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (10) : 1341 - 1347
  • [8] Super-resolution reconstruction in ultrahigh-field MRI
    Payne, Macy
    Mali, Ivina
    Mueller, Thomas
    Cain, Mary
    Segev, Ronen
    Bossmann, Stefan H.
    [J]. BIOPHYSICAL REPORTS, 2023, 3 (02):
  • [9] Reverse polarized inductive coupling to transmit and receive radiofrequency coil arrays
    Celik, Haydar
    Atalar, Ergin
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 446 - 456
  • [10] Application of ultrahigh-field MRI in neuro-oncology
    Radbruch, A.
    Schlemmer, H. -P.
    [J]. RADIOLOGE, 2013, 53 (05): : 411 - 414