A bromide ion-selective polymeric membrane electrode based on a benzo-derivative xanthenium bromide salt

被引:47
|
作者
Shamsipur, M [1 ]
Rouhani, S
Mohajeri, A
Ganjali, MR
Rashidi-Ranjbar, P
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
[2] Bou Ali Sina Univ, Dept Chem, Hamadan, Iran
[3] Univ Tehran, Dept Chem, Tehran, Iran
关键词
bromide ion-selective electrode; 14-phenyldibenzo[a; j]xanthenium bromide; PVC membrane; potentiometry;
D O I
10.1016/S0003-2670(00)00954-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel bromide ion-selective PVC membrane sensor based on 14-phenyldibenzo [a]xanthenium bromide as a membrane carrier was prepared. The electrode has a linear dynamic range between 1.0x10(-1) and 3.2x 10(-5) M with a near-Nernstian slope of 61+/-1 mV per decade and a detection limit of 2.0x10(-5) M. The potentiometric response is independent of the pH of the solution in the pH range 4.5-8.5. The electrode possesses the advantages of low resistance, fast response and good selectivities over a variety of other anions. It was applied as an indicator electrode in potentiometric titration of bromide ions. (C) 2000 Elsevier Science B.V All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 50 条
  • [1] BROMIDE ANALYSIS WITH A BROMIDE ION-SELECTIVE ELECTRODE
    YANG, NF
    KAPUR, V
    SCHLOERB, PR
    FEDERATION PROCEEDINGS, 1984, 43 (04) : 915 - 915
  • [2] CALIBRATION OF BROMIDE ION-SELECTIVE ELECTRODE
    GYENGE, R
    TOTH, K
    KOROS, E
    PUNGOR, E
    MAGYAR KEMIAI FOLYOIRAT, 1977, 83 (03): : 135 - 138
  • [3] DETERMINATION OF BROMIDE INDEX IN MUCOVISCIDOSIS WITH ION-SELECTIVE MEMBRANE ELECTRODE
    GYURKOVITS, K
    LASZLO, A
    ACTA PAEDIATRICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1974, 15 (01): : 49 - 52
  • [4] A nitrate ion-selective electrode based on tetradodecylammonium bromide
    He, Mengmeng
    Li, Yinhua
    Yu, Xiaodong
    Yang, Huizhong
    Sensor Letters, 2015, 13 (11) : 986 - 991
  • [5] ANALYSIS OF BROMIDE ION IN WINE BY ION-SELECTIVE ELECTRODE
    GRAF, JE
    VAUGHN, TE
    KIPP, WH
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1976, 59 (01): : 53 - 55
  • [6] Novel sulfate ion-selective polymeric membrane electrode based on a derivative of pyrilium perchlorate
    Ganjali, MR
    Naji, L
    Poursaberi, T
    Taghizadeh, M
    Pirelahi, H
    Yousefi, M
    Yeganeh-Faal, A
    Shamsipur, M
    TALANTA, 2002, 58 (02) : 359 - 366
  • [7] Solid-contact bromide ion-selective electrode
    Stefanova, OK
    Alagova, ZS
    Khripun, GA
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1995, 68 (08) : 1212 - 1213
  • [8] Flow injection determination of bromide ion in a developer using bromide ion-selective electrode detector
    Masadome, T
    Asano, Y
    Nakamura, T
    TALANTA, 1999, 50 (03) : 595 - 600
  • [9] ION-SELECTIVE ELECTRODE FOR SERUM BROMIDE ASSAY IN PATIENTS WITH EPILEPSY
    KATSU, T
    FURUNO, K
    YAMASHITA, S
    KAWASAKI, H
    GOMITA, Y
    OHTSUKA, Y
    OHTAHARA, S
    CLINICA CHIMICA ACTA, 1995, 234 (1-2) : 157 - 161
  • [10] DETERMINATION OF IODINE VALUES OF LIPIDS BY BROMIDE ION-SELECTIVE ELECTRODE
    ABDELMOETY, EM
    AHMAD, AKS
    ELDIN, MS
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1986, 69 (01): : 67 - 69