Non-Contact Probing in Millimeter Wave Transmitter Characterizations

被引:0
|
作者
Ding, Hanyi [1 ]
Szenher, Francis F. [2 ]
Feng, Kai [2 ]
Burnett, Randall M., II [2 ]
Paganini, Andrea [1 ]
Morton, Robert [2 ]
机构
[1] IBM Corp, 1000 River St, Essex Jct, VT 05452 USA
[2] IBM Corp, Hopewell Jct, NY 12533 USA
关键词
D O I
10.1109/ECTC.2009.5074104
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The lack of access points to internal circuits can prevent full debug and characterization of highly integrated circuits, such as a receiver or transmitter on a chip. To maximize coverage, prevent costly re-spin and improve time to market, innovative characterization and test solutions need to be developed. In this paper loop antennae have been designed and utilized as a non-contact probe in characterizations of on-chip millimeter wave systems. This non-invasive solution is capable to capture (parasitic) signals radiated from the internal stages of a device under characterization otherwise not measurable. In a case study for a super-heterodyne 60GHz transmitter, the data extracted through this inexpensive approach allows for a thorough investigation of how individual functional blocks within the transmitter chip contribute to the overall system performance.
引用
收藏
页码:809 / +
页数:2
相关论文
共 50 条
  • [1] Non-contact Millimeter Wave Dielectric Spectroscopy on Aqueous Solution
    Wu, Che Min
    Cheng, Chia Chin
    Yang, Shang Hua
    2023 48TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, IRMMW-THZ, 2023,
  • [2] Non-contact Guided Wave Excitation in Composite Plate by the Ultrasound Transmitter
    Jurek, Michal
    Kudela, Pawel
    Radzienski, Maciej
    Ostachowicz, Wieslaw
    PROCEEDINGS OF 2018 9TH INTERNATIONAL CONFERENCE ON MECHANICAL AND AEROSPACE ENGINEERING (ICMAE 2018), 2018, : 254 - 258
  • [3] Non-contact subsurface defects characterization by microwave and millimeter wave techniques
    Maazi M.
    Benzaim O.
    Haddadi K.
    Glay D.
    Lasri T.
    Sensing and Imaging: An International Journal, 2006, 7 (4) : 125 - 154
  • [4] Non-Contact Heart Rate Monitoring Based on Millimeter Wave Radar
    Ling, Zongquan
    Zhou, Weinan
    Ren, Yuhao
    Wang, Jiping
    Guo, Liquan
    IEEE Access, 2022, 10 : 74033 - 74044
  • [5] Non-Contact Heart Rate Monitoring Based on Millimeter Wave Radar
    Ling, Zongquan
    Zhou, Weinan
    Ren, Yuhao
    Wang, Jiping
    Guo, Liquan
    IEEE ACCESS, 2022, 10 : 74033 - 74044
  • [6] Non-contact Monitoring of Fatigue Driving Using FMCW Millimeter Wave Radar
    Chen, Honghong
    Han, Xinyu
    Hao, Zhanjun
    Yan, Hao
    Yang, Jie
    ACM TRANSACTIONS ON INTERNET OF THINGS, 2024, 5 (01):
  • [7] Super-Heterodyne Interferometer for Non-Contact Dielectric Measurements on Millimeter Wave Material
    Hock, Goh Chin
    Chakrabarty, Chandan Kumar
    Badjian, Mohammad Hadi
    Devkumar, Sanjay
    Emilliano
    2008 IEEE INTERNATIONAL RF AND MICROWAVE CONFERENCE, PROCEEDINGS, 2008, : 166 - 169
  • [8] A Compact Non-Contact Heart Sound Sensor Based on Millimeter-Wave Radar
    Wen, Li
    Dong, Shuqin
    Gu, Changzhan
    Mao, Jun-Fa
    2022 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2022, : 305 - 307
  • [9] Millimeter-wave emissivity as a metric for the non-contact diagnosis of human skin conditions
    Owda, Amani Yousef
    Salmon, Neil
    Harmer, Stuart William
    Shylo, Sergiy
    Bowring, Nicholas John
    Rezgui, Nacer Ddine
    Shah, Mamta
    BIOELECTROMAGNETICS, 2017, 38 (07) : 559 - 569
  • [10] NON-CONTACT SLEEP ESTIMATION TECHNIQUE WHILE IN BED BY USING MILLIMETER-WAVE RADAR
    Naruta C.
    Matsushita D.
    AIJ Journal of Technology and Design, 2022, 28 (68) : 527 - 532