Electrical impedance tomography via filtered-back projection of fan current distribution: A numerical simulation

被引:0
|
作者
De Simone, BC
Siciliano, R
Pachi, A
Cametti, C
De Luca, F
机构
[1] Univ Roma La Sapienza, Dipartimento Fis, I-00185 Rome, Italy
[2] Univ Roma La Sapienza, INFM, I-00185 Rome, Italy
[3] Univ Calabria, Dipartimento Chim, I-87030 Arcavacata Di Rende, Italy
[4] Univ Roma La Sapienza, Clin Ostetr & Ginecol 2, Rome, Italy
关键词
impedance mapping; EIT; reconstruction algorithm; electrical impedance; filtered back-projection;
D O I
10.1002/bem.10044
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
An approach to electrical impedance tomography (EIT) data acquisition inspired by NMR-filtered back-projection imaging with fan isochromat distribution is proposed. A current projection is generated by injecting current at a certain point of the sample and simultaneously collecting the current itself at different points on the half space opposite the point of current injection. After that, the injection is shifted to another point and collected as above and so on. A very simple algebra and software support the numerical simulations. This method is expected to be more sensitive than the traditional method based on potential measurements. A preliminary low resolution experiment is presented. Bioelectromagnetics 23:516-521, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:516 / 521
页数:6
相关论文
共 31 条
  • [1] Lungs Anomaly Detection by Filtered Back Projection Reconstruction Method in Electrical Impedance Tomography
    Ain, Khusnul
    Kunnadi, Deddy
    Suprijanto
    Santoso, Oerip
    2013 3RD INTERNATIONAL CONFERENCE ON INSTRUMENTATION CONTROL AND AUTOMATION (ICA 2013), 2013, : 133 - 137
  • [2] The acquisition hardware system with direct digital synthesis and filtered back-projection Imaging in electrical impedance tomography
    Xu, Guizhi
    Zhang, Shuai
    Wu, Huanli
    Yang, Shuo
    Geng, Duyan
    Yan, Weili
    Wang, Mingshi
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7758 - 7761
  • [3] An Improved Back-Projection Algorithm for Electrical Impedance Tomography
    Zhu, Qingyou
    Luo, CiYong
    Zhong, ZhanLong
    Chen, MinYou
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1731 - +
  • [4] An Iterative Linear Back-projection Algorithm for Electrical Impedance Tomography
    Wang, Zeying
    Yue, Shihong
    Liu, Xiaoyuan
    2018 13TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2018, : 484 - 489
  • [5] Electrical Impedance Tomography Based on Filter Back Projection Improved by Means Method
    Wang, Mingquan
    Zhao, Jinshuan
    Zhang, Shi
    Wang, Guohua
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 218 - 221
  • [6] Simulation and experiment of electrical impedance tomography with current excitation methods
    Shuai, Wanjun
    Shi, Xuetao
    You, Fusheng
    Fu, Feng
    Liu, Ruigang
    Dong, Xiuzhen
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2008, 29 (11): : 2278 - 2281
  • [7] Solving the Electrical Impedance Tomography (EIT) inverse problem by the conductivity and back projection methods
    Rybina, I. O.
    Rybin, O. I.
    Sharpan, O. B.
    VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA, 2011, (45): : 33 - 45
  • [8] Forward Problem Solution as the Operator of Filtered and Back Projection Matrix to Reconstruct the Various Method of Data collection and the Object Element Model in Electrical Impedance Tomography
    Ain, Khusnul
    Kurniadi, Deddy
    Suprijanto
    Santoso, Oerip
    Wibowo, Arif
    5TH ASIAN PHYSICS SYMPOSIUM (APS 2012), 2015, 1656
  • [9] Different approaches to the completion of the back-projection algorithm in image monitoring by electrical impedance tomography
    Shuai, Wanjun
    Dong, Xiuzhen
    Fu, Feng
    You, Fusheng
    Liu, Xiaodong
    Xu, Canhua
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1638 - 1641
  • [10] Induced current electrical impedance tomography system: experimental results and numerical simulations
    Zlochiver, S
    Radai, MM
    Abboud, S
    Rosenfeld, M
    Dong, XZ
    Liu, RG
    You, FS
    Xiang, HY
    Shi, XT
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 239 - 255