Introduction of organic solvent solutions into inductively coupled plasma-atomic emission spectrometry using a microwave assisted sample introduction system

被引:26
|
作者
Grindlay, Guillermo [1 ]
Maestre, Salvador [1 ]
Gras, Luis [1 ]
Mora, Juan [1 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
关键词
D O I
10.1039/b606995a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microwave assisted sample introduction system based on the use of a TM010 cavity (MWDS2) has been employed for the introduction of 10% w/w organic solvent solutions in inductively coupled plasma atomic emission spectrometry (ICP-AES). Ethanol, propan-2-ol, formic and acetic acids have been used. Firstly, the effect of the incident microwave power and the sample uptake rate on the emission signal was evaluated. For all matrices tested, the higher emission signals were obtained when operating at the highest microwave power (i.e., 290 W) and sample uptake rate (400 mu L min(-1)). Results with the MWDS2 were compared with those afforded by a desolvation system based on the use of a domestic microwave oven (MWDS) and by a conventional sample introduction system (CS). The MWDS2 provides the highest emission signals ( up to 7 and 17 times higher than those with the MWDS and the CS, respectively). As regards the matrix effects originated by the organic solutions, results demonstrate that the use of a microwave-based sample introduction system, mainly the MWDS2, affords a noticeable reduction in the matrix effects originated by the use of organic solvent solutions in ICP-AES with a conventional sample introduction system. This behaviour can be explained by taking into account the solution transport rates afforded by the different sample introduction systems. For all the analytical lines and matrices tested and operating at 400 mL min(-1), the MWDS2 gives rise to signal values that are, on average, 1.2 +/- 0.2 times the signal obtained with water. For the MWDS and the CS, this factor takes values of 1.6 +/- 0.2 and 2.0 +/- 0.5, respectively. Transient matrix effects have been observed operating with the MWDS2 when switching between water and an organic matrix solution. These transient effects result in a drift time about 4.5 times higher than those with a CS.
引用
收藏
页码:1403 / 1411
页数:9
相关论文
共 50 条
  • [1] Introduction of organic solvent solutions into inductively coupled plasma-atomic emission spectrometry using a microwave assisted sample introduction system
    Grindlay, Guillermo
    Maestre, Salvador
    Gras, Luis
    Mora, Juan
    Journal of Analytical Atomic Spectrometry, 2006, 21 (12): : 1403 - 1411
  • [2] Particle sample introduction system for inductively coupled plasma-atomic emission spectrometry
    Greib, L
    Karanassios, V
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (02) : 164 - 180
  • [3] Microwave desolvation for acid sample introduction in inductively coupled plasma atomic emission spectrometry
    Gras, Luis
    Mora, Juan
    Todolí, José L.
    Canals, Antonio
    Hernandis, Vicente
    Spectrochimica acta, Part B: Atomic spectroscopy, 1999, 54 (03): : 469 - 480
  • [4] Microwave desolvation for acid sample introduction in inductively coupled plasma atomic emission spectrometry
    Gras, L
    Mora, J
    Todolí, JL
    Canals, A
    Hernandis, V
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (3-4) : 469 - 480
  • [5] INFLUENCE OF THE SAMPLE INTRODUCTION SYSTEM ON ACID EFFECTS IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY
    CARRE, M
    LEBAS, K
    MARICHY, M
    MERMET, M
    POUSSEL, E
    MERMET, JM
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) : 271 - 283
  • [6] A VERSATILE SAMPLE INTRODUCTION SYSTEM WITH GRAPHITE TUBE FURNACE FOR INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY
    KUMAMARU, T
    OKAMOTO, Y
    MATSUO, H
    APPLIED SPECTROSCOPY, 1987, 41 (05) : 918 - 920
  • [7] Sample introduction for inductively coupled plasma atomic emission spectrometry using an inductively heated vaporizer
    Goltz, Douglas M.
    Skinner, Cameron D.
    Salin, Eric D.
    Spectrochimica acta, Part B: Atomic spectroscopy, 1998, 53 B (6-8): : 1139 - 1147
  • [8] Sample introduction for inductively coupled plasma atomic emission spectrometry using an inductively heated vaporizer
    Goltz, DM
    Skinner, CD
    Salin, ED
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) : 1139 - 1147
  • [9] VOLATILE METAL-CHELATE SAMPLE INTRODUCTION FOR INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY
    BLACK, MS
    BROWNER, RF
    ANALYTICAL CHEMISTRY, 1981, 53 (02) : 249 - 253
  • [10] FLAME SAMPLE INTRODUCTION SYSTEM FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    KARANASSIOS, V
    USYPCHUCK, L
    MOSS, P
    SALIN, ED
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (08) : 1243 - 1247