Centrifugal microfluidic lab-on-a-chip system with automated sample lysis, DNA amplification and microarray hybridization for identification of enterohemorrhagic Escherichia coli culture isolates

被引:22
|
作者
Geissler, Matthias [1 ]
Brassard, Daniel [1 ]
Clime, Liviu [1 ]
Pilar, Ana Victoria C. [2 ]
Malic, Lidija [1 ]
Daoud, Jamal [1 ]
Barrere, Virginie [2 ]
Luebbert, Christian [2 ]
Blais, Burton W. [3 ]
Corneau, Nathalie [2 ]
Veres, Teodor [1 ]
机构
[1] Natl Res Council Canada, Life Sci Div, 75 Mortagne Blvd, Boucherville, PQ J4B 6Y4, Canada
[2] Hlth Canada, Bur Microbial Hazards, 251 Sir Frederick Banting Driveway, Ottawa, ON K1A 0K9, Canada
[3] Canadian Food Inspect Agcy, Ontario Lab Network, Bldg 22,960 Carling Ave, Ottawa, ON K1A 0C6, Canada
关键词
CYANOGEN-BROMIDE ACTIVATION; PATHOGEN DETECTION; FOODBORNE ILLNESS; PCR; IMMOBILIZATION; DEVICES; BIOMOLECULES; MICRODEVICE; INFECTION; POLYMERS;
D O I
10.1039/d0an01232g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of technology for the rapid, automated identification of bacterial culture isolates can help regulatory agencies to shorten response times in food safety surveillance, compliance, and enforcement as well as outbreak investigations. While molecular methods such as polymerase chain reaction (PCR) enable the identification of microbial organisms with high sensitivity and specificity, they generally rely on sophisticated instrumentation and elaborate workflows for sample preparation with an undesirably high level of hands-on engagement. Herein, we describe the design, operation and performance of a lab-on-a-chip system integrating thermal lysis, PCR amplification and microarray hybridization on the same cartridge. The assay is performed on a centrifugal microfluidic platform that allows for pneumatic actuation of liquids during rotation, making it possible to perform all fluidic operations in a fully-automated fashion without the need for integrating active control elements on the microfluidic cartridge. The cartridge, which is fabricated from hard and soft thermoplastic polymers, is compatible with high-volume manufacturing (e.g., injection molding). Chip design and thermal interface were both optimized to ensure efficient heat transfer and allow for fast thermal cycling during the PCR process. The integrated workflow comprises 14 steps and takes less than 2 h to complete. The only manual steps are related to loading of the sample and reagents on the cartridge as well as fluorescence imaging of the microarray. On-chip lysis and PCR amplification both provided results comparable to those obtained by bench-top instrumentation. The microarray, incorporating a panel of oligonucleotide probes for multiplexed detection of seven enterohemorrhagic E. coli priority serotypes, was implemented on a cyclic olefin copolymer substrate using a novel activation scheme that involves the conversion of hydroxyl groups (derived from oxygen plasma treatment) into reactive cyanate ester using cyanogen bromide. On-chip hybridization was demonstrated in a non-quantitative fashion using fluorescently-labelled gene markers for E. coli O157:H7 (rfbO157, eae, vt1, and vt2) obtained through a multiplexed PCR amplification step.
引用
收藏
页码:6831 / 6845
页数:15
相关论文
共 3 条
  • [1] Microfluidic lab-on-a-chip for microbial identification on a DNA microarray
    Lee, Hyun Ho
    Yager, Paul
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2007, 12 (06) : 634 - 639
  • [2] Microfluidic lab-on-a-chip for microbial identification on a DNA microarray
    Hyun Ho Lee
    Paul Yager
    Biotechnology and Bioprocess Engineering, 2007, 12
  • [3] Microfluidic Integration of a Cloth-Based Hybridization Array System (CHAS) for Rapid, Colorimetric Detection of Enterohemorrhagic Escherichia coli (EHEC) Using an Articulated, Centrifugal Platform
    Geissler, Matthias
    Clime, Liviu
    Hoa, Xuyen D.
    Morton, Keith J.
    Hebert, Harold
    Poncelet, Lucas
    Mounier, Maxence
    Deschenes, Mylene
    Gauthier, Martine E.
    Huszczynski, George
    Corneau, Nathalie
    Blais, Burton W.
    Veres, Teodor
    ANALYTICAL CHEMISTRY, 2015, 87 (20) : 10565 - 10572