Analysis of times-to-failure of various turn insulations of form-wound coils under PWM voltage waveform

被引:0
|
作者
Moonesan, Mohammad Saleh [1 ]
Jayaram, Shesha [1 ]
Cherney, Edward [1 ]
Omranipour, Ramtin [2 ]
Ul Haq, Saeed [2 ]
机构
[1] Univ Waterloo, Elect & Comp Dept, Waterloo, ON N2L 3G1, Canada
[2] GE Power Convers, Gen Elect Canada, Peterborough, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
turn insulation; PWM; form-wound; time-to-failure;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents the results of an experimental work to examine the times-to-failure of various types of turn insulations used in form-wound stator coils. A unipolar PWM waveform with a peak of 12 kV, rise time of approximately 270 ns and switching frequency of 3 kHz is used for aging. The types of insulations studied include enamel, Daglas (R), mica tape with polyester film, and enamel plus mica glass tape. The time-to-failure data are analyzed using two-parameter Weibull statistics. The breakdowns are examined microscopically providing information as to the probable reason for the failures. The role of each type of insulation; enamel, Daglas (R) and mica polyester film tapes, and their dimensions are discussed to explain the times-to-failure under PWM aging.
引用
收藏
页码:187 / 190
页数:4
相关论文
共 5 条
  • [1] Electromagnetic transient modeling of form-wound stator coils with stress grading system under PWM excitation
    Hussain, Mohammed Khalil
    Gomez, Pablo
    Espino-Cortes, Fermin P.
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195
  • [2] Analysis of steep-fronted voltage distribution and turn insulation failure in inverter-fed form-wound AC motor
    Tang, YF
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (05) : 1088 - 1096
  • [3] Effect of Voltage Rise Time on Time-to-Failure of Form-Wound Stator Coil Enamelled Turn Insulation
    Moonesan, Mohammad Saleh
    Jayaram, Shesha
    Cherney, Edward
    Omranipour, Ramtin
    Ul Haq, Saeed
    2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 167 - 171
  • [4] Time to Failure of Medium-voltage Form-wound Machine Turn Insulation Stressed by Unipolar Square Waves
    Moonesan, Mohammad Saleh
    Jayaram, Shesha H.
    Cherney, Edward A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) : 3118 - 3125
  • [5] Surge Withstand Capability of Electrically and Thermo-Mechanically Aged Turn Insulation of Medium Voltage Form-Wound AC Stator Coils
    Ul Haq, Saeed
    Omranipour, Ramtin
    Teran, Luis