Use of oxygen sensors for the non-destructive measurement of the oxygen content in modified atmosphere and vacuum packs of cooked chicken patties; impact of oxygen content on lipid oxidation

被引:64
|
作者
Smiddy, M
Papkovskaia, N
Papkovsky, DB
Kerry, JP [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Food Sci Food Technol & Nutr, Cork, Ireland
[2] Natl Univ Ireland Univ Coll Cork, Dept Biochem, Cork, Ireland
关键词
oxygen sensors; lipid oxidation; vacuum packaging; MAP; chicken patties;
D O I
10.1016/S0963-9969(01)00160-0
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Samples were packaged under vacuum and modified atmosphere (70% N-2:30% CO2) and stored at 4 degreesC. under 616 lux fluorescent lighting, for 25 days. Oxygen sensors attached to the inside of the lidding material in MAP packages or inserted into vacuum packages were capable of monitoring changes in oxygen levels. Lipid oxidation of samples was measured at regular intervals. Residual oxygen levels were typical of those found in MAP and vacuum-packaged meats at 0.9-1.1% and 0.11-0.15%. respectively. MAP samples contained the highest levels of oxygen and were significantly (P < 0.05) more oxidised than vacuum-packaged samples. A significant (P < 0.05) reduction in lipid oxidation was observed in vitamin E supplemented patties compared to unsupplemented samples, Vitamin E supplementation had an important effect in counteracting the influence of freely available oxygen on lipid oxidation. The ability to continually assess oxygen levels within packs containing cooked processed meats, through continual, non-destructive assessment using oxygen sensors, provides a far more realistic approach to determining realistic shelf-life stabilities of foods held in vacuum or modified food packing systems. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:577 / 584
页数:8
相关论文
共 13 条
  • [1] Use of oxygen sensors to non-destructively measure the oxygen content in modified atmosphere and vacuum packed beef: impact of oxygen content on lipid oxidation
    Smiddy, M
    Fitzgerald, M
    Kerry, JP
    Papkovsky, DB
    O'Sullivan, CK
    Guilbault, GG
    MEAT SCIENCE, 2002, 61 (03) : 285 - 290
  • [2] Evaluation of oxygen content in commercial modified atmosphere packs (MAP) of processed cooked meats
    Smiddy, M
    Papkovsky, D
    Kerry, J
    FOOD RESEARCH INTERNATIONAL, 2002, 35 (06) : 571 - 575
  • [3] Design and realization of a non-destructive detecting system for oxygen content in glass vials
    Zhu, Gaofeng
    Cheng, Yun
    Zhu, Hongqiu
    Zhang, Yanlei
    2018 NINTH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY IN MEDICINE AND EDUCATION (ITME 2018), 2018, : 766 - 769
  • [4] Non-destructive assessment of oxygen levels in industrial modified atmosphere packaged cheddar cheese
    O'Mahony, FC
    O'Riordan, TC
    Papkovskaia, N
    Kerry, JP
    Papkovsky, DB
    FOOD CONTROL, 2006, 17 (04) : 286 - 292
  • [5] Mathematical modeling, non-destructive analysis and a gas chromatographic method for headspace oxygen measurement of modified atmosphere packaged soy bread
    Pascall, Melvin A.
    Fernandez, Ursula
    Gavara, Rafael
    Allafi, Ahmad
    JOURNAL OF FOOD ENGINEERING, 2008, 86 (04) : 501 - 507
  • [6] Effect of high-oxygen modified atmosphere packaging on the tenderness, lipid oxidation and microbial growth of cooked pork
    Weidong Wang
    Yue-e Sun
    Lihua Ma
    Journal of Food Measurement and Characterization, 2018, 12 : 395 - 402
  • [7] Effect of high-oxygen modified atmosphere packaging on the tenderness, lipid oxidation and microbial growth of cooked pork
    Wang, Weidong
    Sun, Yue-e
    Ma, Lihua
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2018, 12 (01) : 395 - 402
  • [8] Phosphorescent sensor approach for non-destructive measurement of oxygen in packaged foods: Optimisation of disposable oxygen sensors and their characterization over a wide temperature range
    Papkovsky, DB
    Papkovskaia, N
    Smyth, A
    Kerry, J
    Ogurtsov, VI
    ANALYTICAL LETTERS, 2000, 33 (09) : 1755 - 1777
  • [9] An Assessment of the Influence of the Industry Distribution Chain on the Oxygen Levels in Commercial Modified Atmosphere Packaged Cheddar Cheese Using Non-Destructive Oxygen Sensor Technology
    O'Callaghan, Karen A. M.
    Papkovsky, Dmitri B.
    Kerry, Joseph P.
    SENSORS, 2016, 16 (06)
  • [10] Measurement of lipid oxidation and porphyrins in high oxygen modified atmosphere and vacuum-packed minced turkey and pork meat by fluorescence spectra and images
    Veberg, A
    Sorheim, O
    Moan, J
    Iani, V
    Juzenas, P
    Nilsen, AN
    Wold, JP
    MEAT SCIENCE, 2006, 73 (03) : 511 - 520