Assessment of different airflow modeling approaches on a naturally ventilated Mediterranean building

被引:4
|
作者
Faggianelli, Ghjuvan Antone [1 ,2 ]
Brun, Adrien [1 ]
Wurtz, Etienne [1 ]
Muselli, Marc [2 ]
机构
[1] CEA, LITEN, Lab Energet Batiment INES, Le Bourget Du Lac, France
[2] Univ Corse, UMR CNRS SPE 6134, Ajaccio, France
关键词
Natural cross ventilation; Full-scale experiment; Airflow rate measurement; Airflow modeling; Artificial neural networks; ARTIFICIAL NEURAL NETWORKS; CROSS-VENTILATION; OPEN WINDOWS; COEFFICIENTS;
D O I
10.1016/j.enbuild.2015.08.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper focuses on a full-scale experiment to assess and model the airflow rate in a naturally ventilated room using different approaches. The building studied is located in a coastal area of Corsica and mostly affected by thermal breezes phenomena which lead to high airflow rate during day (between 8 and 30 ACH) and lower during night (between 2 and 8 ACH). The first aim of this work is to set up a method in order to measure continuously the airflow rate in cross ventilation configuration using a minimal number of sensors. Our methodology involves direct measurements of velocity on a mesh and use of statistical methods. The second objective is to develop and evaluate different airflow modeling approach in cross natural ventilation configuration. Various levels of complexity are tested and compared: empirical modeling, model calibration and behavioral modeling based on artificial neural networks. In terms of error, the artificial neural network appears to be the best compromise to model the airflow rate and allow to reach a MAE of 1.75 ACH with a one minute time step. Suggested model in this paper can be coupled with a thermal model and is suitable for model based natural ventilation control. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:345 / 354
页数:10
相关论文
共 50 条
  • [1] Modeling naturally ventilated greenhouse designs for Mediterranean climates
    Kacira, M
    Short, TH
    Stowell, R
    [J]. INTERNATIONAL SYMPOSIUM ON GREENHOUSE MANAGEMENT FOR BETTER YIELD AND QUALITY IN MILD WINTER CLIMATES, 1998, (491): : 113 - 118
  • [2] MODELING ENERGY BALANCE AND AIRFLOW CHARACTERISTICS IN A NATURALLY VENTILATED HIGH TUNNEL
    Zheng, M. Z.
    Leib, B.
    Butler, D. M.
    Wright, W.
    Ayers, P.
    Hayes, D.
    [J]. TRANSACTIONS OF THE ASABE, 2017, 60 (05) : 1683 - 1697
  • [3] Quantification of Airflow Patterns in a Naturally Ventilated Building Simulated in a Water Table Apparatus
    Mundhe, Pooja
    Damle, Rashmin Mohan
    Vaidya, Prasad
    Apte, Michael G.
    [J]. SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 1, 2018, : 19 - 24
  • [4] Numerical simulation of airflow in naturally ventilated attics for different attic geometries
    Preetham, B. M.
    Jyothiprakash, K. H.
    Charan, Mridu Sai A. S.
    Gowda, Ashwath
    [J]. HEAT TRANSFER, 2022, 51 (03) : 2604 - 2627
  • [5] Uncertainty in IAQ performance assessment of a naturally ventilated building
    Brohus, H
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2854 - 2859
  • [6] Opening Size Effects on Airflow Pattern and Airflow Rate of a Naturally Ventilated Dairy Building-A CFD Study
    Saha, Chayan Kumer
    Yi, Qianying
    Janke, David
    Hempel, Sabrina
    Amon, Barbara
    Amon, Thomas
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (17):
  • [7] Naturally ventilated greenhouses for Mediterranean climates
    Short, TH
    Van Duyne, G
    [J]. INTERNATIONAL SYMPOSIUM ON STRATEGIES FOR MARKET ORIENTED GREENHOUSE PRODUCTION, 1996, (434): : 229 - 235
  • [8] Wind induced airflow patterns in a naturally ventilated barn
    Morsing, S
    Ikeguchi, A
    Bennetsen, JC
    Strom, JS
    Ravn, P
    Okushima, L
    [J]. SWINE HOUSING, PROCEEDINGS, 2000, : 18 - 25
  • [9] Experimental evaluation of airflow in naturally ventilated active envelopes
    Saelens, D.
    Hens, H.
    [J]. Journal of Thermal Envelope and Building Science, 2001, 25 (02): : 101 - 127
  • [10] Thermal and airflow simulation of a naturally ventilated shopping mall
    da Graca, Guilherme Carrilho
    Martins, Nuno R.
    Horta, Cristina S.
    [J]. ENERGY AND BUILDINGS, 2012, 50 : 177 - 188