Lung Transplantation in Patients with Pretransplantation Donor-Specific Antibodies Detected by Luminex Assay

被引:59
|
作者
Brugiere, Olivier [1 ]
Suberbielle, Caroline [2 ]
Thabut, Gabriel [1 ]
Lhuillier, Elodie [1 ]
Dauriat, Gaelle [1 ]
Metivier, Anne-Cecile [1 ]
Gautreau, Chantal [2 ]
Charron, Dominique [2 ]
Mal, Herve [1 ]
Parquin, Francois [3 ]
Stern, Marc [3 ]
机构
[1] Hop Bichat Claude Bernard, Serv Pneumol & Transplantat Pulm B, F-75018 Paris, France
[2] Hop St Louis, Serv Histocompatibil, Paris, France
[3] Hop Foch, Serv Pneumol & Transplantat Pulm, Suresnes, France
关键词
Luminex; Anti-HLA antibodies; Donor-specific antibodies; Lung transplantation; WORKING FORMULATION; MEDIATED REJECTION; RECIPIENTS; STANDARDIZATION; DESENSITIZATION; NOMENCLATURE; SURVIVAL;
D O I
10.1097/TP.0b013e31827afb0f
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. New methods of solid-phase assays, such as Luminex assay, with high sensitivity in detecting anti-human leukocyte antigen (HLA) antibodies (Abs), have increased the proportion of sensitized candidates waiting for lung transplantation (LTx). However, how to apply these results clinically during graft allocation is debated: strict exclusion of candidates with Luminex-positive results can lead to lost opportunities for Tx. We retrospectively analyzed the clinical impact of pre-LTx Luminex-detected Abs on post-LTx outcomes for patients who underwent LTx before the availability of Luminex assay. Methods. We analyzed data for 56 successive patients who underwent LTx before 2008 and were considered to not have anti-HLA Abs by then-available methods of detection at the date of their LTx. Pre-LTx sera from these patients were retested by Luminex assay. Using log-rank test, freedom from bronchiolitis obliterans syndrome (BOS) and graft survival were compared between patients with and without pre-LTx Luminex-detected anti-HLA Abs classes I and II and donor-specific Abs (DSA) classes I and II. Results. Freedom from bronchiolitis obliterans syndrome was lower, and mortality was higher for patients with than those without pre-LTx Luminex-detected DSA class II (P=0.004 and P=0.007, respectively) but did not differ for patients with and without DSA class I or anti-HLA Abs class I or II. Conclusions. It suggests to avoid attributing graft with forbidden antigens to sensitized candidates with Luminex-detected DSA class II and to evaluate the role of specific posttransplantation protocols for LTx candidates who require emergency LTx.
引用
收藏
页码:761 / 765
页数:5
相关论文
共 50 条
  • [1] Lung Transplantation in Patients with Pre-Transplant Donor-Specific Antibodies (DSA) Detected with Luminex Technique
    Brugiere, O.
    Suberbielle, C.
    Thabut, G.
    Dauriat, G.
    Metivier, A-C
    Mal, H.
    Parquin, F.
    Stern, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S183 - S183
  • [2] Correlation between Luminex donor-specific crossmatches and levels of donor-specific antibodies in pretransplantation screening
    Guillaume, N.
    Mazouz, H.
    Piot, V.
    Presne, C.
    Westeel, P. -F.
    TISSUE ANTIGENS, 2013, 82 (01): : 16 - 20
  • [3] Case report: renal and pancreas transplantation in the presence of donor-specific antibodies detected by Luminex only
    Adams, Ben
    Darke, Chris
    TISSUE ANTIGENS, 2009, 73 (05): : 423 - 423
  • [4] Donor-specific antibodies in lung transplantation
    Hachem, Ramsey R.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2020, 25 (06) : 563 - 567
  • [5] Clinical relevance of pretransplant donor-specific antibodies detected by Luminex only
    Adams, B.
    Fialova, J.
    Ravanan, R.
    Eyres, R.
    Williams, D.
    Rees, M. T.
    Darke, C.
    INTERNATIONAL JOURNAL OF IMMUNOGENETICS, 2008, 35 (06) : 502 - 502
  • [6] Luminex-detected preformed donor-specific HLA antibodies predict lung allograft failure
    Smith, J. D.
    Newell, H.
    Danskine, A. J.
    Carby, M.
    Rose, M. L.
    INTERNATIONAL JOURNAL OF IMMUNOGENETICS, 2008, 35 (06) : 489 - 489
  • [7] Clinical Relevance of Anti-HLA Donor-Specific Antibodies Detected by Luminex Assay in the Development of Rejection After Renal Transplantation
    Luis Caro-Oleas, Jose
    Francisca Gonzalez-Escribano, Maria
    Angel Gentil-Govantes, Miguel
    Jose Acevedo, Maria
    Manuel Gonzalez-Roncero, Francisco
    Bernal Blanco, Gabriel
    Nunez-Roldan, Antonio
    TRANSPLANTATION, 2012, 94 (04) : 338 - 344
  • [8] Intragraft donor-specific antibodies and lung transplantation
    Tikkanen, Jussi M.
    Tinckam, Kathryn
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54 (05)
  • [9] Are all donor-specific antibodies detected by solid phase assay before transplantation clinically relevant?
    Aubert, V
    Venetz, J-P
    Pantaleo, G.
    Pascual, M.
    SWISS MEDICAL WEEKLY, 2009, 139 (9-10) : 23S - 23S
  • [10] Safety of Crossing Donor-specific Antibodies in Lung Transplantation
    Wang, Melissa
    Campbell, Patricia
    Lien, Dale C. C.
    Varughese, Rhea
    Weinkauf, Justin
    Nagendran, Jayan
    Hirji, Alim
    Li, David
    Halloran, Kieran
    TRANSPLANTATION, 2023, 107 (05) : 1172 - 1179