Fellow-eye comparison of posterior capsule opacification with AcrySof SN60AT and AF-1 YA-60BB blue-blocking intraocular lenses

被引:21
|
作者
Hancox, Joanne [1 ]
Spalton, David [1 ]
Cleary, Georgia [1 ]
Boyce, James [2 ]
Nanavaty, Mayank A. [1 ]
Thyagarajan, Sri [1 ]
Marshall, John [2 ]
机构
[1] St Thomas Hosp, Dept Ophthalmol, London SE1 7EH, England
[2] Kings Guys & St Thomas Med Sch, Rayne Inst, London, England
来源
关键词
D O I
10.1016/j.jcrs.2008.05.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate intraindividual differences in posterior capsule opacification (PCO) and visual performance of AcrySof SN60AT (Alcon Laboratories) and AF-1 YA-60BB (Hoya Corp.) intraocular lenses (IOLs). SETTING: Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom. METHODS: In this prospective single-surgeon standardized-surgical-procedure fellow-eye comparison, an AcrySof SN60AT or an AF-1 YA-60BB IOL was randomized to the first eye of 36 patients and fellow-eye surgery was performed within 4 to 6 weeks. Follow-up was at 1, 3, 6,12, and 24 months. Best distance-corrected logMAR visual acuity was measured at 100% and 9% contrast. Contrast sensitivity was measured using the Functional Acuity Contrast Test (FACT) on the Optec 3500 instrument (Stereo Optical Company, Inc.). Color vision was assessed with the Farnsworth Munsell 100-hue test. After pupil dilation, digital retroillumination photographs were taken and the percentage area of PCO was calculated using POCO software. RESULTS: Posterior capsule opacification was significantly greater in the AF-1 YA-60BB group than in the AcrySof SN60AT group at all time points (P<.0001), with the difference greatest at 24 months. At 24 months, 100% contrast visual acuity was significantly better in the AcrySof SN60AT group than in the AF-1 YA-60BB group (P = .0313); 9% contrast visual acuity was significantly better in the AcrySof SN60AT group from 6 months onward. There was no significant difference between groups in color vision or contrast sensitivity. Electron microscopy showed the AcrySof SN60AT IOL has a much sharper posterior edge profile. CONCLUSIONS: The AcrySof SN60AT IOL had better PCO performance and thus visual performance than the AF-1 YA-60BB IOL. This is attributable to the differences in optic edge design.
引用
收藏
页码:1489 / 1494
页数:6
相关论文
共 4 条
  • [1] Fellow-eye comparison of posterior capsule opacification between 2 aspheric microincision intraocular lenses
    Nanavaty, Mayank A.
    Spalton, David J.
    Gala, Kavita B.
    Dhital, Anish
    Boyce, James
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05): : 705 - 711
  • [2] Fellow-eye comparison of posterior capsule opacification rates after implantation of 1CU accommodating and AcrySof MA30 monofocal intraocular lenses
    Hancox, Joanne
    Spalton, David
    Heatley, Catherine
    Jayaram, Hari
    Yip, Jennifer
    Boyce, James
    Marshall, John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 413 - 417
  • [3] Posterior Capsule Opacification with the iMics1 NY-60 and AcrySof SN60WF 1-Piece Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Leydolt, Christina
    Schriefl, Sabine
    Stifter, Eva
    Haszcz, Alexandra
    Menapace, Rupert
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (02) : 375 - 381
  • [4] Posterior Capsule pacification With the iMics1 NY-60 and AcrySof SN6OWF 1-Piece Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Carifi, Gianluca
    Zygoura, Vasiliki
    Deshmukh, Rajesh R.
    Kopsachilis, Nikolaos
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (06) : 1317 - 1317