Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of xanthinol in human plasma and its application in a bioequivalence study of xanthinol nicotinate tablets

被引:1
|
作者
Liu, Hua-qing [1 ]
Su, Meng-xiang [1 ]
Di, Bin [1 ,2 ]
Hang, Tai-jun [1 ]
Hu, Ying [1 ]
Tian, Xiao-qin [1 ]
Zhang, Yin-di [3 ]
Shen, Jian-ping [3 ]
机构
[1] China Pharmaceut Univ, Dept Pharmaceut Anal, Nanjing 210009, Peoples R China
[2] Minist Educ, Key Lab Drug Qual Control & Pharmacovigilance, Nanjing 210009, Peoples R China
[3] Nanjing Med Univ, Inst Clin Pharmacol, Nanjing 210009, Peoples R China
关键词
xanthinol nicotinate; liquid chromatography/tandem mass spectrometry; bioequivalence;
D O I
10.1016/j.jchromb.2008.07.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, rapid liquid chromatographic-electrospray ionization mass spectrometric method for the determination of xanthinol in human plasma was developed and validated. Xanthinol nicotinate in plasma (0.5 mL) was pretreated with 20% trichloroacetic acid for protein precipitation. The samples were separated using a Lichrospher silica (5 mu m, 250 mm x 4.6 mm i.d.). A mobile phase of methanol-water containing 0.1% formic acid (50:50, v/v) was used isocratically eluting at a flow rate of 1 mL/min. Xanthinol and its internal standard (IS), acyclovir, were measured by electrospray ion source in positive selected reaction monitoring mode. The method demonstrated that good linearity ranged from 10,27 to 1642.8 ng/mL with r = 0.9956. The limit of quantification for xanthinol in plasma was 10.27 ng/mL with good accuracy and precision. The mean plasma extraction recovery of xanthinol was in the range of 90.9-100.2%. The intra- and inter-batch variability values were less than 4.8% and 7.9% (relative standard deviation, R.S.D.), respectively. The established method has been successfully applied to a bioequivalence study of two xanthinol nicotinate tablets for 20 healthy volunteers. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [1] Liquid chromatography-tandem mass spectrometry method for the determination of propranolol in human plasma and its application to a bioequivalence study
    do Carmo Borges, Ney Carter
    Rigato, Hamilton Modesto
    de Oliveira, Paulo Renato
    Nogueira, Daniele Rubert
    Moreno, Ronilson Agnaldo
    Dalmora, Sergio Luiz
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (19) : 2927 - 2941
  • [2] Development and validation of a liquid chromatography-tandem mass spectrometry method for topotecan determination in beagle dog plasma and its application in a bioequivalence study
    Ye, Ling
    Shi, Jian
    Wan, Shanhe
    Yang, Xiaoshan
    Wang, Ying
    Zhang, Jiajie
    Zheng, Dayong
    Liu, Zhongqiu
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (11) : 1532 - 1539
  • [3] Liquid chromatography-tandem mass spectrometry method development and validation for the determination of erlotinib in human plasma and its application in pharmacokinetic study
    N. T. Ramarao
    S. Vidyadhara
    M. V. Basaveswara Rao
    R. L. C. Sasidhar
    R. Surendra Yadav
    Journal of Analytical Chemistry, 2015, 70 : 1488 - 1494
  • [4] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of phenylephrine in human plasma and its application to a pharmacokinetic study
    Ptácek, P.
    Klíma, J.
    Macek, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 858 (1-2): : 263 - 268
  • [5] Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of lenalidomide in human plasma and its application on bioequivalence studies
    R. Gopinath
    S. T. Narenderan
    M. Kumar
    B. Babu
    Journal of Analytical Science and Technology, 10
  • [6] Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of lenalidomide in human plasma and its application on bioequivalence studies
    Gopinath, R.
    Narenderan, S. T.
    Kumar, M.
    Babu, B.
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2019, 10 (01)
  • [7] Liquid chromatography-tandem mass spectrometry method development and validation for the determination of erlotinib in human plasma and its application in pharmacokinetic study
    Ramarao, N. T.
    Vidyadhara, S.
    Rao, M. V. Basaveswara
    Sasidhar, R. L. C.
    Yadav, R. Surendra
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (12) : 1488 - 1494
  • [8] Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Vardenafil and Its Application of Bioequivalence
    Gan, Kok Zheng
    Widodo, Riyanto Teguh
    Chik, Zamri
    Teh, Lay Kek
    Rofiee, Mohd Salleh
    Mohamad Yusof, Mohd Izwan
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 2021
  • [9] Development and validation of a high-performance liquid chromatography-tandem mass spectrometry for the determination of penciclovir in human plasma: Application to a bioequivalence study
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 382 - 388
  • [10] Ultrafast liquid chromatography-tandem mass spectrometry determination of donepezil in human plasma: application to a bioequivalence study
    Huang, Yan-Wen
    Ding, Li
    Chen, Yuan-Ming
    Lin, Wei-chen
    Lin, Fei
    Hsieh, Yunsheng