An instantly usable paper-based screen-printed solid-state KCl/Ag/AgCl reference electrode with long-term stability

被引:39
|
作者
Shitanda, Isao [1 ,2 ]
Komoda, Masato [1 ]
Hoshi, Yoshinao [1 ,2 ]
Itagaki, Masayuki [1 ,2 ]
机构
[1] Tokyo Univ Sci, Fac Sci & Technol, Dept Pure & Appl Chem, Noda, Chiba 2788510, Japan
[2] Tokyo Univ Sci, Res Inst Sci & Technol, Noda, Chiba 2788510, Japan
关键词
AG/AGCL REFERENCE ELECTRODE; POTENTIOMETRIC MEASUREMENTS; 3-ELECTRODE SYSTEM; LIQUID-JUNCTION; FABRICATION; PH;
D O I
10.1039/c5an00617a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An instantly usable screen-printed paper-based Ag/AgCl electrode was fabricated for use as a cost-effective disposable reference electrode. The reference electrode showed potential stability for approximately 75 h. The setup time, which is less than 1 min, is much shorter than those for similar previously reported electrodes.
引用
收藏
页码:6481 / 6484
页数:4
相关论文
共 18 条
  • [1] A screen-printed Ag/AgCl reference electrode with long-term stability for electroanalytical applications
    Dawkins, Rebecca C.
    Wen, Dingchen
    Hart, Judy N.
    Vepsalainen, Mikko
    [J]. ELECTROCHIMICA ACTA, 2021, 393
  • [2] Screen-printed Paper-based Three-electrode System with Long-term Stable and Instantaneously Usable Reference Electrode
    Shitanda, Isao
    Komoda, Masato
    Hoshi, Yoshinao
    Itagaki, Masayuki
    [J]. CHEMISTRY LETTERS, 2018, 47 (12) : 1502 - 1504
  • [3] Improvement in the long-term stability of screen-printed planar type solid-state Ag/AgCl reference electrode by introducing poly(dimethylsiloxane) liquid junction
    Shitanda, Isao
    Kiryu, Hiroyuki
    Itagaki, Masayuki
    [J]. ELECTROCHIMICA ACTA, 2011, 58 : 528 - 531
  • [4] Instantaneously usable screen-printed silver/silver sulfate reference electrode with long-term stability
    Komoda, Masato
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2019, 103 : 133 - 137
  • [5] Solid-state sodium-selective sensors based on screen-printed Ag/AgCl reference electrodes
    Walsh, S
    Diamond, D
    McLaughlin, J
    McAdams, E
    Woolfson, D
    Jones, D
    Bonner, M
    [J]. ELECTROANALYSIS, 1997, 9 (17) : 1318 - 1324
  • [6] Fabrication and Characterization of a Fully Screen-Printed Ag/AgCl Reference Electrode Using Silica Gel Inks Exhibiting Instantaneous Usability and Long-Term Stability
    Komoda, Masato
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    [J]. ELECTROCHEMISTRY, 2019, 87 (01) : 65 - 69
  • [7] Stable Full-Inkjet-Printed Solid-State Ag/AgCl Reference Electrode
    Moya, Ana
    Pol, Roberto
    Martinez-Cuadrado, Alfonso
    Villa, Rosa
    Gabriel, Gemma
    Baeza, Mireia
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (24) : 15539 - 15546
  • [8] FABRICATION OF A PVC-BASED SOLID-STATE Ag/AgCl REFERENCE ELECTRODE
    Wu, Yi-Min
    Chen, Lin-Chi
    [J]. 2019 IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2019), 2019, : 244 - 246
  • [9] An unusually stable solid state Ag|AgCl reference electrode for long term continuous measurements based on a crosslinked polyvinyl acetate)/KCl composite
    Macedo, David S.
    Vepsalainen, Mikko
    Acharya, Durga
    Wood, Colin D.
    Wen, Dingchen
    Thomson, Liam
    Peacock, Stephen
    Rodopoulos, Theo
    Hogan, Conor F.
    [J]. ELECTROCHIMICA ACTA, 2021, 368
  • [10] Fabrication of a planar-form screen-printed solid electrolyte modified Ag/AgCl reference electrode for application in a potentiometric biosensor
    Liao, Wei-Yin
    Chou, Tse-Chuan