The Effect of Treatment Time and Frequency Difference on Acoustic Power of High-intensity Focused Ultrasound

被引:0
|
作者
Wang, Yue [1 ]
Zheng, Xiaoyu [2 ]
Liao, Qingyao [2 ]
Xiao, Ling [1 ]
机构
[1] Chinese Acad Sci, Inst Acoust, Beijing, Peoples R China
[2] Chongqing Med Univ, Dept Cardiol, Affiliated Hosp 2, Chongqing, Peoples R China
关键词
HIFU; acoustic power; treatment time; dual-frequency HIFU; frequency difference;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
HIFU is a noninvasive tissue ablation method for treatment of a broad range of cancer and benign maladies. Its ultrasonic energy can also be used to activate or deactivate nerves in recent years. To avoid unnecessary tissue ablation caused by high acoustic energy, treatment time is split. Dual-frequency ultrasound takes advantage of cavitation, but in many cases, increases the complexity of the HIFU system. The objective of this research was to measure the acoustic power of HIFU transducer with split treatment time, and compare it with that of the transducer with traditional treatment time. The effect of frequency difference on acoustic power of dual-frequency HIFU transducer is also evaluated in experiments. The results demonstrate that split treatment time has little effect on acoustic power. As frequency difference increases, the acoustic power does not decrease monotonically. Nevertheless, if frequency difference is above 10kHz, the acoustic power significantly decreases compared with that of smaller frequency differences. For dual-frequency HIFU, appropriate frequency difference should be chosen according to their respective application.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] TREATMENT OF GLAUCOMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    VALTOT, F
    KOPEL, J
    HAUT, J
    [J]. INTERNATIONAL OPHTHALMOLOGY, 1989, 13 (1-2) : 167 - 170
  • [2] TREATMENT OF GLAUCOMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    BURGESS, SEP
    SILVERMAN, RH
    COLEMAN, DJ
    YABLONSKI, ME
    LIZZI, FL
    DRILLER, J
    ROSADO, A
    DENNIS, PH
    [J]. OPHTHALMOLOGY, 1986, 93 (06) : 831 - 838
  • [3] Effect of acoustic nonlinearity on heating of biological tissue by high-intensity focused ultrasound
    Filonenko, EA
    Khokhlova, VA
    [J]. ACOUSTICAL PHYSICS, 2001, 47 (04) : 468 - 475
  • [4] Effect of acoustic nonlinearity on heating of biological tissue by high-intensity focused ultrasound
    E. A. Filonenko
    V. A. Khokhlova
    [J]. Acoustical Physics, 2001, 47 : 468 - 475
  • [5] Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor
    Zhou, Yufeng
    [J]. MEDICAL ENGINEERING & PHYSICS, 2015, 37 (03) : 335 - 340
  • [6] The affection on the tissue lesions of difference frequency in dual-frequency high-intensity focused ultrasound (HIFU)
    He, PZ
    Xia, RM
    Duan, SM
    Shou, WD
    Qian, DC
    [J]. ULTRASONICS SONOCHEMISTRY, 2006, 13 (04) : 339 - 344
  • [7] Effect of pulse repetition frequency of high-intensity focused ultrasound on in vitro thrombolysis
    Yang, Wenjing
    Zhou, Yufeng
    [J]. ULTRASONICS SONOCHEMISTRY, 2017, 35 : 152 - 160
  • [8] High-intensity focused ultrasound in the treatment of solid tumours
    Kennedy, JE
    [J]. NATURE REVIEWS CANCER, 2005, 5 (04) : 321 - 327
  • [9] HIGH-INTENSITY FOCUSED ULTRASOUND IN THE TREATMENT OF PROSTATIC TISSUE
    BIHRLE, R
    FOSTER, RS
    SANGHVI, NT
    FRY, FJ
    DONOHUE, JP
    [J]. UROLOGY, 1994, 43 (02) : 21 - 26
  • [10] High-Intensity Focused Ultrasound in the Treatment of Breast Cancer
    Feril, Loreto B., Jr.
    Fernan, Rodney L.
    Tachibana, Katsuro
    [J]. CURRENT MEDICINAL CHEMISTRY, 2021, 28 (25) : 5179 - 5188