Noise reduction in functional near-infrared spectroscopy signals by independent component analysis

被引:136
|
作者
Santosa, Hendrik [1 ]
Hong, Melissa Jiyoun [2 ]
Kim, Sung-Phil [3 ]
Hong, Keum-Shik [1 ,4 ]
机构
[1] Pusan Natl Univ, Dept Cognomechatron Engn, Pusan 609735, South Korea
[2] Columbia Univ, Dept Educ Policy & Social Anal, New York, NY 10027 USA
[3] Korea Univ, Dept Brain & Cognit Engn, Seoul 136713, South Korea
[4] Pusan Natl Univ, Sch Mech Engn, Pusan 609735, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2013年 / 84卷 / 07期
基金
新加坡国家研究基金会;
关键词
LOW-FREQUENCY OSCILLATIONS; CEREBRAL HEMODYNAMICS; BRAIN ACTIVITY; TIME-SERIES; ACTIVATION; FLUCTUATIONS; OXYGENATION; METABOLISM; ALGORITHMS; FNIRS;
D O I
10.1063/1.4812785
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Functional near-infrared spectroscopy (fNIRS) is used to detect concentration changes of oxyhemoglobin and deoxy-hemoglobin in the human brain. The main difficulty entailed in the analysis of fNIRS signals is the fact that the hemodynamic response to a specific neuronal activation is contaminated by physiological and instrument noises, motion artifacts, and other interferences. This paper proposes independent component analysis (ICA) as a means of identifying the original hemodynamic response in the presence of noises. The original hemodynamic response was reconstructed using the primary independent component (IC) and other, less-weighting-coefficient ICs. In order to generate experimental brain stimuli, arithmetic tasks were administered to eight volunteer subjects. The t-value of the reconstructed hemodynamic response was improved by using the ICs found in the measured data. The best t-value out of 16 low-pass-filtered signals was 37, and that of the reconstructed one was 51. Also, the average t-value of the eight subjects' reconstructed signals was 40, whereas that of all of their low-pass-filtered signals was only 20. Overall, the results showed the applicability of the ICA-based method to noise-contamination reduction in brain mapping. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Independent component analysis of event-related functional near-infrared spectroscopy (fNIRS)
    Jiao, Yun
    Zhou, Zhenyu
    Wang, Hui
    Yang, Hongyu
    Ruan, Zongcai
    Gong, Hui
    Lu, Zuhong
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 440 - +
  • [2] Concurrent Spatiotemporal Analysis of Functional Near-Infrared Spectroscopy Data Using Independent Component Analysis
    Yuan, Zhen
    2013 6TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), VOLS 1-3, 2013, : 794 - 798
  • [3] On fractality of functional near-infrared spectroscopy signals: analysis and applications
    Zhu, Li
    Haghani, Sasan
    Najafizadeh, Laleh
    NEUROPHOTONICS, 2020, 7 (02)
  • [4] Noise Reduction in Silicon Photomultipliers for Use in Functional Near-Infrared Spectroscopy
    Mazzillo M.
    Mello D.
    Barbarino P.P.
    Romeo M.
    Musienko Y.
    Sciuto A.
    Libertino S.
    Lombardo S.
    Fallica G.
    IEEE Transactions on Radiation and Plasma Medical Sciences, 2017, 1 (03): : 212 - 220
  • [5] Comparison of principal and independent component analysis in removing extracerebral interference from near-infrared spectroscopy signals
    Virtanen, Jaakko
    Noponen, Tommi
    Merilainen, Pekka
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)
  • [6] Separating heart and brain: on the reduction of physiological noise from multichannel functional near-infrared spectroscopy (fNIRS) signals
    Bauernfeind, G.
    Wriessnegger, S. C.
    Daly, I.
    Mueller-Putz, G. R.
    JOURNAL OF NEURAL ENGINEERING, 2014, 11 (05)
  • [7] Investigation of different approaches for noise reduction in functional near-infrared spectroscopy signals for brain–computer interface applications
    A. Janani
    M. Sasikala
    Neural Computing and Applications, 2017, 28 : 2889 - 2903
  • [8] Spatiotemporal and time-frequency analysis of functional near infrared spectroscopy brain signals using independent component analysis
    Yuan, Zhen
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (10)
  • [9] Investigation of different approaches for noise reduction in functional near-infrared spectroscopy signals for brain-computer interface applications
    Janani, A.
    Sasikala, M.
    NEURAL COMPUTING & APPLICATIONS, 2017, 28 (10): : 2889 - 2903
  • [10] Classification of functional near-infrared spectroscopy signals applying reduction of scalp hemodynamic artifact
    Sato, Takanori
    Sugai, Kyoko
    Nambu, Isao
    Wada, Yasuhiro
    2014 UKACC INTERNATIONAL CONFERENCE ON CONTROL (CONTROL), 2014, : 708 - 713